使用两个电磁传感器评估整个美国气候参考网络的土壤含水量和体积电导率

IF 2.5 3区 地球科学 Q3 ENVIRONMENTAL SCIENCES
Timothy B. Wilson, John Kochendorfer, Howard J. Diamond, Tilden P. Meyers, Mark Hall, Temple R. Lee, Rick D. Saylor, Praveena Krishnan, Ronald D. Leeper, Michael A. Palecki
{"title":"使用两个电磁传感器评估整个美国气候参考网络的土壤含水量和体积电导率","authors":"Timothy B. Wilson, John Kochendorfer, Howard J. Diamond, Tilden P. Meyers, Mark Hall, Temple R. Lee, Rick D. Saylor, Praveena Krishnan, Ronald D. Leeper, Michael A. Palecki","doi":"10.1002/vzj2.20336","DOIUrl":null,"url":null,"abstract":"Soil bulk electrical conductivity (BEC) was evaluated alongside soil volumetric water content (VWC) and soil temperature measurements using the HydraProbe (model HydraProbe, Stevens Water Monitoring Systems, Inc.) (hereafter called HP) with accuracy range of BEC ≤ 0.3 S m<jats:sup>−1</jats:sup>, and the time domain reflectometry (TDR)‐315L Probe (model TDR‐315L, Acclima, Inc.) (hereafter called AP) suitable for BEC up to 0.6 S m<jats:sup>−1</jats:sup>, at 23 stations of the U.S. Climate Reference Network. Previous evaluations revealed inconsistent performance of both sensors in some clay soils using manufacturer‐recommended calibrations in converting dielectric permittivity measurements to VWC. Here, we found that hourly values of BEC reached 0.6 S m<jats:sup>−1</jats:sup> in high clay content soils and exceeded 2 S m<jats:sup>−1</jats:sup> in high saline soils, and these high values of BEC were associated with poor performance and failures of both HP and AP sensors. Large values of BEC occurred in predominantly saturated soils where VWC values reached about 0.5 m<jats:sup>3</jats:sup> m<jats:sup>−3</jats:sup> for saline soils and about 0.7 m<jats:sup>3</jats:sup> m<jats:sup>−3</jats:sup> for clay soils, while low magnitudes of BEC were associated with low soil water content and seldomly saturated soils. Low hourly BEC values of less than 0.1 S m<jats:sup>−1</jats:sup> were observed in wide variety of soil types, where sensor performance was typically excellent. The most influential factor on BEC was high soil water content conditions. Although dielectric permittivity measurements in estimating the soil water content were sensitive to BEC as some high clay content and high salinity soils increased BEC, the impact of large BEC on dielectric permittivity measurements was smaller in the well‐drained top soil layers than in deep soil layers that remained near saturation. Soil temperature had only a small impact on BEC. With high clay content and high salinity, the specific area of clay minerals was also associated with the magnitude of BEC.","PeriodicalId":23594,"journal":{"name":"Vadose Zone Journal","volume":"38 1","pages":""},"PeriodicalIF":2.5000,"publicationDate":"2024-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of soil water content and bulk electrical conductivity across the U.S. Climate Reference Network using two electromagnetic sensors\",\"authors\":\"Timothy B. Wilson, John Kochendorfer, Howard J. Diamond, Tilden P. Meyers, Mark Hall, Temple R. Lee, Rick D. Saylor, Praveena Krishnan, Ronald D. Leeper, Michael A. Palecki\",\"doi\":\"10.1002/vzj2.20336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Soil bulk electrical conductivity (BEC) was evaluated alongside soil volumetric water content (VWC) and soil temperature measurements using the HydraProbe (model HydraProbe, Stevens Water Monitoring Systems, Inc.) (hereafter called HP) with accuracy range of BEC ≤ 0.3 S m<jats:sup>−1</jats:sup>, and the time domain reflectometry (TDR)‐315L Probe (model TDR‐315L, Acclima, Inc.) (hereafter called AP) suitable for BEC up to 0.6 S m<jats:sup>−1</jats:sup>, at 23 stations of the U.S. Climate Reference Network. Previous evaluations revealed inconsistent performance of both sensors in some clay soils using manufacturer‐recommended calibrations in converting dielectric permittivity measurements to VWC. Here, we found that hourly values of BEC reached 0.6 S m<jats:sup>−1</jats:sup> in high clay content soils and exceeded 2 S m<jats:sup>−1</jats:sup> in high saline soils, and these high values of BEC were associated with poor performance and failures of both HP and AP sensors. Large values of BEC occurred in predominantly saturated soils where VWC values reached about 0.5 m<jats:sup>3</jats:sup> m<jats:sup>−3</jats:sup> for saline soils and about 0.7 m<jats:sup>3</jats:sup> m<jats:sup>−3</jats:sup> for clay soils, while low magnitudes of BEC were associated with low soil water content and seldomly saturated soils. Low hourly BEC values of less than 0.1 S m<jats:sup>−1</jats:sup> were observed in wide variety of soil types, where sensor performance was typically excellent. The most influential factor on BEC was high soil water content conditions. Although dielectric permittivity measurements in estimating the soil water content were sensitive to BEC as some high clay content and high salinity soils increased BEC, the impact of large BEC on dielectric permittivity measurements was smaller in the well‐drained top soil layers than in deep soil layers that remained near saturation. Soil temperature had only a small impact on BEC. With high clay content and high salinity, the specific area of clay minerals was also associated with the magnitude of BEC.\",\"PeriodicalId\":23594,\"journal\":{\"name\":\"Vadose Zone Journal\",\"volume\":\"38 1\",\"pages\":\"\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vadose Zone Journal\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1002/vzj2.20336\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vadose Zone Journal","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1002/vzj2.20336","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

使用 HydraProbe(型号 HydraProbe,Stevens Water Monitoring Systems, Inc.以下简称 HP)和时域反射仪 (TDR)-315L 探头(型号 TDR-315L,Acclima,Inc.)(以下简称 AP)进行了评估,前者的精度范围为 BEC ≤ 0.3 S m-1,后者的精度范围为 BEC ≤ 0.6 S m-1。之前的评估显示,在将介电常数测量值转换为 VWC 时,使用制造商推荐的校准方法,这两种传感器在某些粘土中的性能并不一致。在这里,我们发现在粘土含量较高的土壤中,每小时的 BEC 值达到 0.6 S m-1,而在高盐度土壤中则超过 2 S m-1,这些高 BEC 值与 HP 和 AP 传感器的性能不佳和故障有关。较大的 BEC 值出现在主要饱和的土壤中,盐碱土的 VWC 值达到约 0.5 立方米/立方米,粘土的 VWC 值达到约 0.7 立方米/立方米,而较低的 BEC 值则与土壤含水量低和很少饱和有关。在各种类型的土壤中都能观察到每小时小于 0.1 S m-1 的较低 BEC 值,在这些土壤中,传感器的性能通常非常出色。对 BEC 影响最大的因素是土壤含水量高。虽然在估算土壤含水量时介电常数测量对 BEC 很敏感,因为一些高粘土含量和高盐度土壤会增加 BEC,但在排水良好的表层土壤中,大 BEC 对介电常数测量的影响要小于接近饱和的深层土壤。土壤温度对介电常数的影响很小。在粘土含量高和盐度高的情况下,粘土矿物的比面积也与 BEC 的大小有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of soil water content and bulk electrical conductivity across the U.S. Climate Reference Network using two electromagnetic sensors
Soil bulk electrical conductivity (BEC) was evaluated alongside soil volumetric water content (VWC) and soil temperature measurements using the HydraProbe (model HydraProbe, Stevens Water Monitoring Systems, Inc.) (hereafter called HP) with accuracy range of BEC ≤ 0.3 S m−1, and the time domain reflectometry (TDR)‐315L Probe (model TDR‐315L, Acclima, Inc.) (hereafter called AP) suitable for BEC up to 0.6 S m−1, at 23 stations of the U.S. Climate Reference Network. Previous evaluations revealed inconsistent performance of both sensors in some clay soils using manufacturer‐recommended calibrations in converting dielectric permittivity measurements to VWC. Here, we found that hourly values of BEC reached 0.6 S m−1 in high clay content soils and exceeded 2 S m−1 in high saline soils, and these high values of BEC were associated with poor performance and failures of both HP and AP sensors. Large values of BEC occurred in predominantly saturated soils where VWC values reached about 0.5 m3 m−3 for saline soils and about 0.7 m3 m−3 for clay soils, while low magnitudes of BEC were associated with low soil water content and seldomly saturated soils. Low hourly BEC values of less than 0.1 S m−1 were observed in wide variety of soil types, where sensor performance was typically excellent. The most influential factor on BEC was high soil water content conditions. Although dielectric permittivity measurements in estimating the soil water content were sensitive to BEC as some high clay content and high salinity soils increased BEC, the impact of large BEC on dielectric permittivity measurements was smaller in the well‐drained top soil layers than in deep soil layers that remained near saturation. Soil temperature had only a small impact on BEC. With high clay content and high salinity, the specific area of clay minerals was also associated with the magnitude of BEC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vadose Zone Journal
Vadose Zone Journal 环境科学-环境科学
CiteScore
5.60
自引率
7.10%
发文量
61
审稿时长
3.8 months
期刊介绍: Vadose Zone Journal is a unique publication outlet for interdisciplinary research and assessment of the vadose zone, the portion of the Critical Zone that comprises the Earth’s critical living surface down to groundwater. It is a peer-reviewed, international journal publishing reviews, original research, and special sections across a wide range of disciplines. Vadose Zone Journal reports fundamental and applied research from disciplinary and multidisciplinary investigations, including assessment and policy analyses, of the mostly unsaturated zone between the soil surface and the groundwater table. The goal is to disseminate information to facilitate science-based decision-making and sustainable management of the vadose zone. Examples of topic areas suitable for VZJ are variably saturated fluid flow, heat and solute transport in granular and fractured media, flow processes in the capillary fringe at or near the water table, water table management, regional and global climate change impacts on the vadose zone, carbon sequestration, design and performance of waste disposal facilities, long-term stewardship of contaminated sites in the vadose zone, biogeochemical transformation processes, microbial processes in shallow and deep formations, bioremediation, and the fate and transport of radionuclides, inorganic and organic chemicals, colloids, viruses, and microorganisms. Articles in VZJ also address yet-to-be-resolved issues, such as how to quantify heterogeneity of subsurface processes and properties, and how to couple physical, chemical, and biological processes across a range of spatial scales from the molecular to the global.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信