术后颌间弹性牵引有助于双侧下颌骨骨折可吸收钢板固定的稳定性

Yuxin Lin, Kun Lv
{"title":"术后颌间弹性牵引有助于双侧下颌骨骨折可吸收钢板固定的稳定性","authors":"Yuxin Lin, Kun Lv","doi":"10.1097/scs.0000000000010100","DOIUrl":null,"url":null,"abstract":"The use of absorbable plates can be challenging for mandibular fractures involving bilateral dentition. Chewing and mouth opening movements may cause loosening or breakage of absorbable materials, leading to displacement of bone segments and resulting in malocclusion. The use of absorbable materials for bilateral mandibular fracture surgery itself raises concerns for surgeons. Timely intermaxillary elastic traction is essential for these patients after surgery to maintain correct occlusion. The surgical approaches were performed with intraoral mandibular sulcus incisions. During the surgery, intermaxillary fixation screws were implanted and steel wires were used for intermaxillary ligation and fixation to restore the occlusal. After the fractured segments were sequentially reduced, they were fixed with inion 2.0 absorbable plates. The patient underwent intermaxillary elastic traction for 1 week. Elastic mask was used to assist in stabilizing the position of the jawbone and maintaining occlusion. After discharge, the patient continued traction at home for 3 weeks before removing the intermaxillary fixation screws. The patient recovered well after surgery without any complications. The postoperative occlusal relationship is good. Postoperative CT showed good reduction of the fractured segments. For the case reported in this article, elastic traction was promptly implemented after surgery. We emphasize that restoring occlusion is always the treatment goal for jawbone fractures. We believe that keeping the intermaxillary fixation screws for a month is a wise choice to be prepared for unexpected needs.","PeriodicalId":501649,"journal":{"name":"The Journal of Craniofacial Surgery","volume":"300 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Postoperative Intermaxillary Elastic Traction Contributes to the Stability of Absorbable Plates Fixation for Bilateral Mandibular Fracture.\",\"authors\":\"Yuxin Lin, Kun Lv\",\"doi\":\"10.1097/scs.0000000000010100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of absorbable plates can be challenging for mandibular fractures involving bilateral dentition. Chewing and mouth opening movements may cause loosening or breakage of absorbable materials, leading to displacement of bone segments and resulting in malocclusion. The use of absorbable materials for bilateral mandibular fracture surgery itself raises concerns for surgeons. Timely intermaxillary elastic traction is essential for these patients after surgery to maintain correct occlusion. The surgical approaches were performed with intraoral mandibular sulcus incisions. During the surgery, intermaxillary fixation screws were implanted and steel wires were used for intermaxillary ligation and fixation to restore the occlusal. After the fractured segments were sequentially reduced, they were fixed with inion 2.0 absorbable plates. The patient underwent intermaxillary elastic traction for 1 week. Elastic mask was used to assist in stabilizing the position of the jawbone and maintaining occlusion. After discharge, the patient continued traction at home for 3 weeks before removing the intermaxillary fixation screws. The patient recovered well after surgery without any complications. The postoperative occlusal relationship is good. Postoperative CT showed good reduction of the fractured segments. For the case reported in this article, elastic traction was promptly implemented after surgery. We emphasize that restoring occlusion is always the treatment goal for jawbone fractures. We believe that keeping the intermaxillary fixation screws for a month is a wise choice to be prepared for unexpected needs.\",\"PeriodicalId\":501649,\"journal\":{\"name\":\"The Journal of Craniofacial Surgery\",\"volume\":\"300 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Craniofacial Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/scs.0000000000010100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Craniofacial Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/scs.0000000000010100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于涉及双侧牙齿的下颌骨骨折,使用可吸收钢板可能具有挑战性。咀嚼和张口运动可能会导致可吸收材料松动或破损,从而导致骨段移位,造成错颌畸形。使用可吸收材料进行双侧下颌骨骨折手术本身就会引起外科医生的担忧。这些患者术后必须及时进行颌间弹性牵引,以保持正确的咬合。手术方法采用口内下颌沟切口。手术中植入颌间固定螺钉,使用钢丝进行颌间结扎和固定,以恢复咬合。在依次缩小骨折部分后,用 Inion 2.0 可吸收钢板进行固定。患者接受了为期一周的颌间弹性牵引。弹性面罩用于辅助稳定颌骨位置和维持咬合。出院后,患者在家继续牵引了3周,然后取出了颌间固定螺钉。患者术后恢复良好,未出现任何并发症。术后咬合关系良好。术后 CT 显示骨折断端缩小良好。对于本文报告的病例,术后及时实施了弹性牵引。我们强调,恢复咬合始终是颌骨骨折的治疗目标。我们认为,将颌间距离固定螺钉保留一个月是一个明智的选择,以备不时之需。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Postoperative Intermaxillary Elastic Traction Contributes to the Stability of Absorbable Plates Fixation for Bilateral Mandibular Fracture.
The use of absorbable plates can be challenging for mandibular fractures involving bilateral dentition. Chewing and mouth opening movements may cause loosening or breakage of absorbable materials, leading to displacement of bone segments and resulting in malocclusion. The use of absorbable materials for bilateral mandibular fracture surgery itself raises concerns for surgeons. Timely intermaxillary elastic traction is essential for these patients after surgery to maintain correct occlusion. The surgical approaches were performed with intraoral mandibular sulcus incisions. During the surgery, intermaxillary fixation screws were implanted and steel wires were used for intermaxillary ligation and fixation to restore the occlusal. After the fractured segments were sequentially reduced, they were fixed with inion 2.0 absorbable plates. The patient underwent intermaxillary elastic traction for 1 week. Elastic mask was used to assist in stabilizing the position of the jawbone and maintaining occlusion. After discharge, the patient continued traction at home for 3 weeks before removing the intermaxillary fixation screws. The patient recovered well after surgery without any complications. The postoperative occlusal relationship is good. Postoperative CT showed good reduction of the fractured segments. For the case reported in this article, elastic traction was promptly implemented after surgery. We emphasize that restoring occlusion is always the treatment goal for jawbone fractures. We believe that keeping the intermaxillary fixation screws for a month is a wise choice to be prepared for unexpected needs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信