新型便携式北欧腿筋测试装置(IVMES H-Bord)的可靠性和有效性

IF 1.1 4区 医学 Q4 ENGINEERING, MECHANICAL
Cengiz Akarçeşme, Elif Cengizel, Sümer Alvurdu, Emre Bağcı, Emre Altundağ, Çağdaş Özgür Cengizel, Ömer Şenel
{"title":"新型便携式北欧腿筋测试装置(IVMES H-Bord)的可靠性和有效性","authors":"Cengiz Akarçeşme, Elif Cengizel, Sümer Alvurdu, Emre Bağcı, Emre Altundağ, Çağdaş Özgür Cengizel, Ömer Şenel","doi":"10.1177/17543371241239725","DOIUrl":null,"url":null,"abstract":"The aim of this study is to determine the reliability and validity of the IVMES H-Bord eccentric hamstring strength measurement device. Thirty-eight healthy male athletes (age: 20.9 ± 2.11 years, height: 1.79 ± 0.03 m, body weight: 76.6 kg, body mass index: 22.6 ± 0.69 kg/m<jats:sup>2</jats:sup>) participated in this study. Each test protocol was applied in eccentric mode and isometric mode respectively. Between-session test-retest reliability of the IVMES H-Bord was analyzed for the intraclass correlation coefficient (ICC) with 95% coefficient intervals (CI). Validity of the IVMES H-Bord was examined for eccentric mode (NHT<jats:sub>ecc</jats:sub>), and isometric mode (NHT<jats:sub>iso</jats:sub>) using Pearson’s correlation coefficient with 95% CI and limits of agreement. Bland-Altman plots were also created to provide a representation of the agreement between two test devices. Strong correlations, good ICC values and acceptable typical errors of the estimate were observed between the NHT and isokinetic strength testing (IST) during both limbs with no proportional bias for validity analysis. In conclusion, the “IVMES H-Bord” is a reliable and valid measurement device for eccentric hamstring muscle strength and it provides important advantages for medical staff, fitness coaches and practitioners because it is portable, low cost, and field-based assessment.","PeriodicalId":20674,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","volume":"263 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)\",\"authors\":\"Cengiz Akarçeşme, Elif Cengizel, Sümer Alvurdu, Emre Bağcı, Emre Altundağ, Çağdaş Özgür Cengizel, Ömer Şenel\",\"doi\":\"10.1177/17543371241239725\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study is to determine the reliability and validity of the IVMES H-Bord eccentric hamstring strength measurement device. Thirty-eight healthy male athletes (age: 20.9 ± 2.11 years, height: 1.79 ± 0.03 m, body weight: 76.6 kg, body mass index: 22.6 ± 0.69 kg/m<jats:sup>2</jats:sup>) participated in this study. Each test protocol was applied in eccentric mode and isometric mode respectively. Between-session test-retest reliability of the IVMES H-Bord was analyzed for the intraclass correlation coefficient (ICC) with 95% coefficient intervals (CI). Validity of the IVMES H-Bord was examined for eccentric mode (NHT<jats:sub>ecc</jats:sub>), and isometric mode (NHT<jats:sub>iso</jats:sub>) using Pearson’s correlation coefficient with 95% CI and limits of agreement. Bland-Altman plots were also created to provide a representation of the agreement between two test devices. Strong correlations, good ICC values and acceptable typical errors of the estimate were observed between the NHT and isokinetic strength testing (IST) during both limbs with no proportional bias for validity analysis. In conclusion, the “IVMES H-Bord” is a reliable and valid measurement device for eccentric hamstring muscle strength and it provides important advantages for medical staff, fitness coaches and practitioners because it is portable, low cost, and field-based assessment.\",\"PeriodicalId\":20674,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology\",\"volume\":\"263 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/17543371241239725\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/17543371241239725","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定 IVMES H-Bord 偏心腘绳肌力量测量装置的可靠性和有效性。38 名健康男性运动员(年龄:20.9 ± 2.11 岁,身高:1.79 ± 0.03 米,体重:76.6 公斤,体重指数:22.6 ± 0.69 公斤/平方米)参加了此次研究:22.6 ± 0.69 kg/m2)参加了此次研究。每个测试方案分别采用偏心模式和等长模式。对 IVMES H-Bord 的两次测试之间的可靠性进行了类内相关系数 (ICC) 分析,并得出了 95% 的系数区间 (CI)。使用皮尔逊相关系数(95% CI)和一致性限值检验了 IVMES H-Bord 偏心模式(NHTecc)和等长模式(NHTiso)的有效性。此外,还绘制了 "Bland-Altman "图,以显示两种测试设备之间的一致性。在进行有效性分析时,NHT 和双侧肢体等动力量测试 (IST) 之间的相关性很强,ICC 值良好,估计的典型误差可接受,且没有比例偏差。总之,"IVMES H-Bord "是一种可靠有效的偏心腘绳肌力量测量设备,由于其便携、低成本和现场评估的特点,为医务人员、健身教练和从业人员提供了重要的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability and validity of the new portable Nordic hamstring test device (IVMES H-Bord)
The aim of this study is to determine the reliability and validity of the IVMES H-Bord eccentric hamstring strength measurement device. Thirty-eight healthy male athletes (age: 20.9 ± 2.11 years, height: 1.79 ± 0.03 m, body weight: 76.6 kg, body mass index: 22.6 ± 0.69 kg/m2) participated in this study. Each test protocol was applied in eccentric mode and isometric mode respectively. Between-session test-retest reliability of the IVMES H-Bord was analyzed for the intraclass correlation coefficient (ICC) with 95% coefficient intervals (CI). Validity of the IVMES H-Bord was examined for eccentric mode (NHTecc), and isometric mode (NHTiso) using Pearson’s correlation coefficient with 95% CI and limits of agreement. Bland-Altman plots were also created to provide a representation of the agreement between two test devices. Strong correlations, good ICC values and acceptable typical errors of the estimate were observed between the NHT and isokinetic strength testing (IST) during both limbs with no proportional bias for validity analysis. In conclusion, the “IVMES H-Bord” is a reliable and valid measurement device for eccentric hamstring muscle strength and it provides important advantages for medical staff, fitness coaches and practitioners because it is portable, low cost, and field-based assessment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
20.00%
发文量
51
审稿时长
>12 weeks
期刊介绍: The Journal of Sports Engineering and Technology covers the development of novel sports apparel, footwear, and equipment; and the materials, instrumentation, and processes that make advances in sports possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信