{"title":"光电倍增管电压对密封式 NaI (Tl) 闪烁探测器性能的影响","authors":"Hongchi Zhou, Fang Liu, Xin Yuan, Jun Wu, Guanda Li","doi":"10.1155/2024/5206668","DOIUrl":null,"url":null,"abstract":"We explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage and the distance between the gamma-ray sources (<sup>137</sup>Cs and <sup>60</sup>Co) and the scintillator detector. The experimental results showed that energy resolution decreased when the PMT voltage increased, and the energy resolution of NaI (Tl) detectors reached a smaller value (6.92%, 6.76%, and 6.56%), especially with the PMT voltage in the range of 575–595 V. In addition, a suitable distance between the gamma-ray source and the scintillator (5 cm) can also effectively reduce the energy resolution. We established the simulation models of the experimental NaI (Tl) detectors and simulated their energy spectra. The simulation results in the peak area agreed with the experimental results. A possible better PMT voltage choice has been proposed to obtain a smaller energy resolution.","PeriodicalId":21629,"journal":{"name":"Science and Technology of Nuclear Installations","volume":"149 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors\",\"authors\":\"Hongchi Zhou, Fang Liu, Xin Yuan, Jun Wu, Guanda Li\",\"doi\":\"10.1155/2024/5206668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage and the distance between the gamma-ray sources (<sup>137</sup>Cs and <sup>60</sup>Co) and the scintillator detector. The experimental results showed that energy resolution decreased when the PMT voltage increased, and the energy resolution of NaI (Tl) detectors reached a smaller value (6.92%, 6.76%, and 6.56%), especially with the PMT voltage in the range of 575–595 V. In addition, a suitable distance between the gamma-ray source and the scintillator (5 cm) can also effectively reduce the energy resolution. We established the simulation models of the experimental NaI (Tl) detectors and simulated their energy spectra. The simulation results in the peak area agreed with the experimental results. A possible better PMT voltage choice has been proposed to obtain a smaller energy resolution.\",\"PeriodicalId\":21629,\"journal\":{\"name\":\"Science and Technology of Nuclear Installations\",\"volume\":\"149 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Science and Technology of Nuclear Installations\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/5206668\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science and Technology of Nuclear Installations","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2024/5206668","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors
We explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage and the distance between the gamma-ray sources (137Cs and 60Co) and the scintillator detector. The experimental results showed that energy resolution decreased when the PMT voltage increased, and the energy resolution of NaI (Tl) detectors reached a smaller value (6.92%, 6.76%, and 6.56%), especially with the PMT voltage in the range of 575–595 V. In addition, a suitable distance between the gamma-ray source and the scintillator (5 cm) can also effectively reduce the energy resolution. We established the simulation models of the experimental NaI (Tl) detectors and simulated their energy spectra. The simulation results in the peak area agreed with the experimental results. A possible better PMT voltage choice has been proposed to obtain a smaller energy resolution.
期刊介绍:
Science and Technology of Nuclear Installations is an international scientific journal that aims to make available knowledge on issues related to the nuclear industry and to promote development in the area of nuclear sciences and technologies. The endeavor associated with the establishment and the growth of the journal is expected to lend support to the renaissance of nuclear technology in the world and especially in those countries where nuclear programs have not yet been developed.