具有短衰减时间的新型可乐丽波长变换光纤的性能

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Shoma Kodama, Hokuto Kobayashi, Wataru Okinaga, Kota Nakagiri, Yasuhiro Nakajima, Masashi Yokoyama
{"title":"具有短衰减时间的新型可乐丽波长变换光纤的性能","authors":"Shoma Kodama, Hokuto Kobayashi, Wataru Okinaga, Kota Nakagiri, Yasuhiro Nakajima, Masashi Yokoyama","doi":"10.1093/ptep/ptae055","DOIUrl":null,"url":null,"abstract":"We measure the decay time and the attenuation length of newly developed wavelength-shifting fibers, YS series from Kuraray, which have fast response. Using a 405 nm laser, the decay times of the YS-2, 4, and 6 are measured to be 3.64 ± 0.04 ns, 2.15 ± 0.03 ns, and 1.47 ± 0.02 ns, respectively, for the light injection distance of 10 cm. The decay time of Y-11 is measured to be 7.10 ± 0.09 ns using the same system. All fibers are found to have similar attenuation lengths of more than 4 meters. When combined with the plastic scintillators EJ-200 and EJ-204, the YS series have better time resolution than Y-11, with light yields of 60–100% of Y-11.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of new Kuraray wavelength-shifting fibers with short decay time\",\"authors\":\"Shoma Kodama, Hokuto Kobayashi, Wataru Okinaga, Kota Nakagiri, Yasuhiro Nakajima, Masashi Yokoyama\",\"doi\":\"10.1093/ptep/ptae055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We measure the decay time and the attenuation length of newly developed wavelength-shifting fibers, YS series from Kuraray, which have fast response. Using a 405 nm laser, the decay times of the YS-2, 4, and 6 are measured to be 3.64 ± 0.04 ns, 2.15 ± 0.03 ns, and 1.47 ± 0.02 ns, respectively, for the light injection distance of 10 cm. The decay time of Y-11 is measured to be 7.10 ± 0.09 ns using the same system. All fibers are found to have similar attenuation lengths of more than 4 meters. When combined with the plastic scintillators EJ-200 and EJ-204, the YS series have better time resolution than Y-11, with light yields of 60–100% of Y-11.\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1093/ptep/ptae055\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1093/ptep/ptae055","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

我们测量了可乐丽公司新开发的具有快速响应能力的 YS 系列波长转换光纤的衰减时间和衰减长度。使用 405 nm 激光,在光注入距离为 10 cm 时,测得 YS-2、4 和 6 的衰减时间分别为 3.64 ± 0.04 ns、2.15 ± 0.03 ns 和 1.47 ± 0.02 ns。使用同一系统测得 Y-11 的衰减时间为 7.10 ± 0.09 ns。所有光纤的衰减长度相似,均超过 4 米。当与塑料闪烁体 EJ-200 和 EJ-204 结合使用时,YS 系列的时间分辨率比 Y-11 更高,光产率为 Y-11 的 60-100%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance of new Kuraray wavelength-shifting fibers with short decay time
We measure the decay time and the attenuation length of newly developed wavelength-shifting fibers, YS series from Kuraray, which have fast response. Using a 405 nm laser, the decay times of the YS-2, 4, and 6 are measured to be 3.64 ± 0.04 ns, 2.15 ± 0.03 ns, and 1.47 ± 0.02 ns, respectively, for the light injection distance of 10 cm. The decay time of Y-11 is measured to be 7.10 ± 0.09 ns using the same system. All fibers are found to have similar attenuation lengths of more than 4 meters. When combined with the plastic scintillators EJ-200 and EJ-204, the YS series have better time resolution than Y-11, with light yields of 60–100% of Y-11.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信