临床实践中甲状腺激素测定的可疑干扰

Q4 Medicine
Pablo José Ferreira Ocampo , Alicia Torregrossa Benavent , Elena Jaime Lara , Francisca Almodóvar Ruiz
{"title":"临床实践中甲状腺激素测定的可疑干扰","authors":"Pablo José Ferreira Ocampo ,&nbsp;Alicia Torregrossa Benavent ,&nbsp;Elena Jaime Lara ,&nbsp;Francisca Almodóvar Ruiz","doi":"10.1016/j.appr.2024.100199","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Analytical methods providing plasma values of thyroid hormones are vulnerable to various interferences that alter the results. An example is the presence of anti-thyroid hormone antibodies (anti-HT), common in patients with autoimmune hypothyroidism, which can disrupt the instrument signal and yield a falsely elevated hormone value in the sample. Only 50% of cases of analytical interferences are reported. These interferences can lead to misdiagnoses and inappropriate therapeutic management, resulting in harm to the patient and increased healthcare expenditure.</p></div><div><h3>Case</h3><p>A 72-year-old woman with autoimmune hypothyroidism on replacement therapy. Routine analysis reveals an elevation in T4 with TSH also above the reference range, when the expected outcome would be TSH suppression. This pattern is confirmed twice with the same analyzer. As the patient is asymptomatic, analytical interference is suspected. Following a protocol established by the Clinical Analysis laboratory, major known interferences are ruled out, leading to the detection of anti-HT as the cause of the false T4 value. Management changes, with medication dosage now monitored solely based on TSH levels.</p></div><div><h3>Conclusions</h3><p>Interferences lead to erroneous interpretations. In this case, considering overdosing of treatment and reducing the LT4 dose would induce hypothyroidism symptoms. Assuming another form of hyperthyroidism, discontinuing treatment, or initiating anti-thyroid drugs would result in similar harm. By detecting the interference, unnecessary iatrogenesis is avoided.</p></div>","PeriodicalId":52231,"journal":{"name":"Atencion Primaria Practica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2605073024000099/pdfft?md5=62328cf263c1721de9fbe114201a9fb5&pid=1-s2.0-S2605073024000099-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Sospecha de la interferencia en la determinación de las hormonas tiroideas en la práctica clínica real\",\"authors\":\"Pablo José Ferreira Ocampo ,&nbsp;Alicia Torregrossa Benavent ,&nbsp;Elena Jaime Lara ,&nbsp;Francisca Almodóvar Ruiz\",\"doi\":\"10.1016/j.appr.2024.100199\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Analytical methods providing plasma values of thyroid hormones are vulnerable to various interferences that alter the results. An example is the presence of anti-thyroid hormone antibodies (anti-HT), common in patients with autoimmune hypothyroidism, which can disrupt the instrument signal and yield a falsely elevated hormone value in the sample. Only 50% of cases of analytical interferences are reported. These interferences can lead to misdiagnoses and inappropriate therapeutic management, resulting in harm to the patient and increased healthcare expenditure.</p></div><div><h3>Case</h3><p>A 72-year-old woman with autoimmune hypothyroidism on replacement therapy. Routine analysis reveals an elevation in T4 with TSH also above the reference range, when the expected outcome would be TSH suppression. This pattern is confirmed twice with the same analyzer. As the patient is asymptomatic, analytical interference is suspected. Following a protocol established by the Clinical Analysis laboratory, major known interferences are ruled out, leading to the detection of anti-HT as the cause of the false T4 value. Management changes, with medication dosage now monitored solely based on TSH levels.</p></div><div><h3>Conclusions</h3><p>Interferences lead to erroneous interpretations. In this case, considering overdosing of treatment and reducing the LT4 dose would induce hypothyroidism symptoms. Assuming another form of hyperthyroidism, discontinuing treatment, or initiating anti-thyroid drugs would result in similar harm. By detecting the interference, unnecessary iatrogenesis is avoided.</p></div>\",\"PeriodicalId\":52231,\"journal\":{\"name\":\"Atencion Primaria Practica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2605073024000099/pdfft?md5=62328cf263c1721de9fbe114201a9fb5&pid=1-s2.0-S2605073024000099-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atencion Primaria Practica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2605073024000099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atencion Primaria Practica","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2605073024000099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

导言:提供血浆甲状腺激素值的分析方法很容易受到各种干扰因素的影响而改变结果。例如,自身免疫性甲状腺功能减退症患者体内常见的抗甲状腺激素抗体(抗-HT)会干扰仪器信号,导致样本中的激素值虚假升高。只有 50% 的分析干扰案例被报告。这些干扰可导致误诊和不恰当的治疗管理,给患者造成伤害并增加医疗支出。常规分析显示 T4 升高,TSH 也高于参考范围,而预期结果是 TSH 受抑制。使用同一台分析仪对这一模式进行了两次确认。由于患者无症状,怀疑分析受到干扰。按照临床分析实验室制定的方案,排除了已知的主要干扰,最终检测出抗-HT 是造成假 T4 值的原因。结论干扰会导致错误的解释。在本病例中,如果考虑过量治疗并减少LT4剂量,就会诱发甲状腺功能减退症状。假定出现另一种甲状腺功能亢进,停止治疗或开始服用抗甲状腺药物也会造成类似的伤害。通过检测干扰,可以避免不必要的先天性疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sospecha de la interferencia en la determinación de las hormonas tiroideas en la práctica clínica real

Introduction

Analytical methods providing plasma values of thyroid hormones are vulnerable to various interferences that alter the results. An example is the presence of anti-thyroid hormone antibodies (anti-HT), common in patients with autoimmune hypothyroidism, which can disrupt the instrument signal and yield a falsely elevated hormone value in the sample. Only 50% of cases of analytical interferences are reported. These interferences can lead to misdiagnoses and inappropriate therapeutic management, resulting in harm to the patient and increased healthcare expenditure.

Case

A 72-year-old woman with autoimmune hypothyroidism on replacement therapy. Routine analysis reveals an elevation in T4 with TSH also above the reference range, when the expected outcome would be TSH suppression. This pattern is confirmed twice with the same analyzer. As the patient is asymptomatic, analytical interference is suspected. Following a protocol established by the Clinical Analysis laboratory, major known interferences are ruled out, leading to the detection of anti-HT as the cause of the false T4 value. Management changes, with medication dosage now monitored solely based on TSH levels.

Conclusions

Interferences lead to erroneous interpretations. In this case, considering overdosing of treatment and reducing the LT4 dose would induce hypothyroidism symptoms. Assuming another form of hyperthyroidism, discontinuing treatment, or initiating anti-thyroid drugs would result in similar harm. By detecting the interference, unnecessary iatrogenesis is avoided.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atencion Primaria Practica
Atencion Primaria Practica Medicine-Family Practice
CiteScore
0.30
自引率
0.00%
发文量
40
审稿时长
24 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信