对使用不同类型氧化锆和不同边缘水泥空间厚度制作的三单元固定锆桥的真实度和安装精度进行数字化评估

Q4 Dentistry
Mutaz Omran Mosa, Adel F. Ibraheem, H. Hussein
{"title":"对使用不同类型氧化锆和不同边缘水泥空间厚度制作的三单元固定锆桥的真实度和安装精度进行数字化评估","authors":"Mutaz Omran Mosa, Adel F. Ibraheem, H. Hussein","doi":"10.1055/s-0043-1777010","DOIUrl":null,"url":null,"abstract":"\n Objective The aim of this study was to measure the internal, marginal fitness, and trueness of a three-unit fixed zirconium bridge fabricated using two types of zirconia and different marginal cement space thicknesses.\n Methods and Materials Thirty-two aluminum master models, constructed by computer numerical control (CNC) milling machines using aluminum rod, representing two prepared aluminum abutments (the upper first premolar and the first molar) were chosen due to differences in shape and dimensions, which may affect adaptation. It may also be considered one of the most common cases in clinical practice and a missing second premolars were used to fabricate a three-unit fixed partial zirconium bridge. A master model was scanned with an intraoral scanner. Fixed dental prostheses (FDPs) were fabricated with two designs (single-layer high-translucent [HT] Katana and ultra-translucent multilayer (UTML] zirconia Katana) and two marginal cement space thicknesses (0 and 25μm for HT and ML). These specimens are divided according to marginal cement space and type of zirconia into four groups, each containing eight samples. Group A: 25-μm marginal cement space with single-layer HT zirconia. Group B: 25-μm marginal gap with UTML zirconia. Group C: 0 μm marginal gap single-layer HT zirconia. Group D: 0 μm marginal gap with UTML zirconia. Fitness and trueness of the fabricated three-unit FDPs were evaluated by scanning the silicone replica of the cement space and analyzing the thickness of the silicone replica in the three-dimensional inspection software (Geomagic Control X, Morrisville, North Carolina, USA).\n Results Highest mean value of internal gap was recorded at the molar abutment of group D (95.05, ± 3.42 μm), while the lowest was recorded at the premolar abutment of group A (57.12, ± 2.43μm). For marginal gap, the lowest marginal gap was also recorded at the premolar abutment of group A (36.14, ± 3.94μm), and the highest was at the molar abutment of group D (84.74, ± 2.98 μm).For trueness, group A showed the lowest root mean square (RMS) of mean with both abutments compared with group D, which recorded the highest RMS of mean for trueness.\n Conclusion The marginal cement space thickness affects the FPD internal, marginal fitness, and trueness; single-layer HT (Katana) zirconia shows better fitness and trueness than UTML (Katana).","PeriodicalId":37771,"journal":{"name":"European Journal of General Dentistry","volume":"12 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digital Evaluation of the Trueness and Fitting Accuracy of a Three-Unit Fixed Zirconium Bridge Fabricated from Different Types of Zirconia and Different Marginal Cement Space Thickness\",\"authors\":\"Mutaz Omran Mosa, Adel F. Ibraheem, H. Hussein\",\"doi\":\"10.1055/s-0043-1777010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Objective The aim of this study was to measure the internal, marginal fitness, and trueness of a three-unit fixed zirconium bridge fabricated using two types of zirconia and different marginal cement space thicknesses.\\n Methods and Materials Thirty-two aluminum master models, constructed by computer numerical control (CNC) milling machines using aluminum rod, representing two prepared aluminum abutments (the upper first premolar and the first molar) were chosen due to differences in shape and dimensions, which may affect adaptation. It may also be considered one of the most common cases in clinical practice and a missing second premolars were used to fabricate a three-unit fixed partial zirconium bridge. A master model was scanned with an intraoral scanner. Fixed dental prostheses (FDPs) were fabricated with two designs (single-layer high-translucent [HT] Katana and ultra-translucent multilayer (UTML] zirconia Katana) and two marginal cement space thicknesses (0 and 25μm for HT and ML). These specimens are divided according to marginal cement space and type of zirconia into four groups, each containing eight samples. Group A: 25-μm marginal cement space with single-layer HT zirconia. Group B: 25-μm marginal gap with UTML zirconia. Group C: 0 μm marginal gap single-layer HT zirconia. Group D: 0 μm marginal gap with UTML zirconia. Fitness and trueness of the fabricated three-unit FDPs were evaluated by scanning the silicone replica of the cement space and analyzing the thickness of the silicone replica in the three-dimensional inspection software (Geomagic Control X, Morrisville, North Carolina, USA).\\n Results Highest mean value of internal gap was recorded at the molar abutment of group D (95.05, ± 3.42 μm), while the lowest was recorded at the premolar abutment of group A (57.12, ± 2.43μm). For marginal gap, the lowest marginal gap was also recorded at the premolar abutment of group A (36.14, ± 3.94μm), and the highest was at the molar abutment of group D (84.74, ± 2.98 μm).For trueness, group A showed the lowest root mean square (RMS) of mean with both abutments compared with group D, which recorded the highest RMS of mean for trueness.\\n Conclusion The marginal cement space thickness affects the FPD internal, marginal fitness, and trueness; single-layer HT (Katana) zirconia shows better fitness and trueness than UTML (Katana).\",\"PeriodicalId\":37771,\"journal\":{\"name\":\"European Journal of General Dentistry\",\"volume\":\"12 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of General Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1777010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of General Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1777010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的 本研究旨在测量使用两种氧化锆和不同边缘粘结剂厚度制作的三单元固定锆桥的内部、边缘密合度和真实度。方法和材料 由于形状和尺寸上的差异可能会影响适应性,因此选择了 32 个由计算机数控(CNC)铣床用铝棒制作的铝母模型,代表两个准备好的铝基台(上第一前磨牙和第一臼齿)。这也可以被认为是临床实践中最常见的病例之一,缺失的第二前磨牙被用来制作三单元固定部分锆桥。使用口内扫描仪对主模型进行扫描。用两种设计(单层高透光[HT] Katana 和超透光多层[UTML] 氧化锆 Katana)和两种边缘骨水泥间隙厚度(HT 和 ML 为 0 和 25μm)制作了固定义齿(FDP)。这些试样根据边缘骨水泥间隙和氧化锆类型分为四组,每组包含八个试样。A 组:25μm 的边缘骨水泥间隙,单层 HT 氧化锆。B 组:25μm 边缘间隙,使用 UTML 氧化锆。C 组:0 μm 边缘间隙的单层 HT 氧化锆。D 组边缘间隙为 0 μm 的UTML 氧化锆。通过扫描骨水泥间隙的硅胶复型,并在三维检测软件(Geomagic Control X,美国北卡罗来纳州莫里斯维尔市)中分析硅胶复型的厚度,评估制作的三单位 FDP 的合适度和真实度。结果 D组磨牙基台的内间隙平均值最高(95.05,±3.42 μm),A组前磨牙基台的内间隙平均值最低(57.12,±2.43 μm)。在边缘间隙方面,A 组前磨牙基台的边缘间隙最小(36.14,±3.94μm),D 组磨牙基台的边缘间隙最大(84.74,±2.98 μm)。结论 边缘骨水泥间隙厚度会影响 FPD 的内部、边缘密合度和真实度;单层 HT(Katana)氧化锆比 UTML(Katana)显示出更好的密合度和真实度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Digital Evaluation of the Trueness and Fitting Accuracy of a Three-Unit Fixed Zirconium Bridge Fabricated from Different Types of Zirconia and Different Marginal Cement Space Thickness
Objective The aim of this study was to measure the internal, marginal fitness, and trueness of a three-unit fixed zirconium bridge fabricated using two types of zirconia and different marginal cement space thicknesses. Methods and Materials Thirty-two aluminum master models, constructed by computer numerical control (CNC) milling machines using aluminum rod, representing two prepared aluminum abutments (the upper first premolar and the first molar) were chosen due to differences in shape and dimensions, which may affect adaptation. It may also be considered one of the most common cases in clinical practice and a missing second premolars were used to fabricate a three-unit fixed partial zirconium bridge. A master model was scanned with an intraoral scanner. Fixed dental prostheses (FDPs) were fabricated with two designs (single-layer high-translucent [HT] Katana and ultra-translucent multilayer (UTML] zirconia Katana) and two marginal cement space thicknesses (0 and 25μm for HT and ML). These specimens are divided according to marginal cement space and type of zirconia into four groups, each containing eight samples. Group A: 25-μm marginal cement space with single-layer HT zirconia. Group B: 25-μm marginal gap with UTML zirconia. Group C: 0 μm marginal gap single-layer HT zirconia. Group D: 0 μm marginal gap with UTML zirconia. Fitness and trueness of the fabricated three-unit FDPs were evaluated by scanning the silicone replica of the cement space and analyzing the thickness of the silicone replica in the three-dimensional inspection software (Geomagic Control X, Morrisville, North Carolina, USA). Results Highest mean value of internal gap was recorded at the molar abutment of group D (95.05, ± 3.42 μm), while the lowest was recorded at the premolar abutment of group A (57.12, ± 2.43μm). For marginal gap, the lowest marginal gap was also recorded at the premolar abutment of group A (36.14, ± 3.94μm), and the highest was at the molar abutment of group D (84.74, ± 2.98 μm).For trueness, group A showed the lowest root mean square (RMS) of mean with both abutments compared with group D, which recorded the highest RMS of mean for trueness. Conclusion The marginal cement space thickness affects the FPD internal, marginal fitness, and trueness; single-layer HT (Katana) zirconia shows better fitness and trueness than UTML (Katana).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of General Dentistry
European Journal of General Dentistry Dentistry-Dentistry (all)
CiteScore
1.00
自引率
0.00%
发文量
21
期刊介绍: European Journal of General Dentistry (EJGD) is one of the leading open-access international dental journal within the field of Dentistry. The aim of EJGD is publishing novel and high-quality research papers, as well as to influence the practice of dentistry at clinician, research, industry and policy-maker level on an international basis. EJGD publishes articles on all disciplines of dentistry including the cariology, orthodontics, oral surgery, preventive dentistry, periodontology, endodontology, operative dentistry, fixed and removable prosthodontics, dental biomaterials science, long-term clinical trials including epidemiology and oral health, technology transfer of new scientific instrumentation or procedures, as well as clinically relevant oral biology and translational research.Moreover, EJGD also publish the scientific researches evaluating the use of new biomaterials, new drugs and new methods for treatment of patients with different kinds of oral and maxillofacial diseases or defects, the diagnosis of oral and maxillofacial diseases with new methods, etc. Moreover, researches on the quality of life, psychological interventions, improving disease treatment outcomes, the prevention, diagnosis and management of cancer therapeutic complications, rehabilitation, palliative and end of life care, and support teamwork for cancer care and oral health care for old patients are also welcome. EJGD publishes research articles, case reports, reviews and comparison studies evaluating materials and methods in the all fields of related to dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信