M. Abdillah, Mukhnizar Mukhnizar, Risal Abu, Afdal Afdal, Z. Zulkarnain
{"title":"用于灰处理的 Sullair Ls20-150h 喷油螺杆式压缩机性能分析(PLTU Teluk Sirih 案例研究)","authors":"M. Abdillah, Mukhnizar Mukhnizar, Risal Abu, Afdal Afdal, Z. Zulkarnain","doi":"10.31004/jutin.v7i1.25494","DOIUrl":null,"url":null,"abstract":"PLTU Teluk Sirih is a coal-fired steam power plant as an energy source that produces ash with a capacity of 2 . The compressor is a medium for transferring ash by using compressed air. The compressor used is a SCREEW OIL INJECTED SULLAIR LS20-150H compressor. Currently there is a decrease in performance on the compressor, which initially had a compression ratio of 1,600 Psia, polytropic head 14,500,599, capacity 10,938,438, flow rate 11,379,622 lb/s, efficiency 98.5%. After analyzing this compressor, the data obtained was a compression ratio of 1,540 Psia, polytropic head 13,805,166, capacity 10,950,733, flow rate 11,392,412, and efficiency of 95.3%. The reason is because the compressor room area does not have an active blower so that dirt/ash stuck to the radiator fins causes heat transfer to be hampered and this greatly affects the performance of the compressor parts to work optimally","PeriodicalId":17759,"journal":{"name":"Jurnal Teknik Industri Terintegrasi","volume":"18 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisis Kinerja Kompressor Screw Oil Injected Sullair Ls20-150h untuk Ash Handling (Study Kasus PLTU Teluk Sirih)\",\"authors\":\"M. Abdillah, Mukhnizar Mukhnizar, Risal Abu, Afdal Afdal, Z. Zulkarnain\",\"doi\":\"10.31004/jutin.v7i1.25494\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PLTU Teluk Sirih is a coal-fired steam power plant as an energy source that produces ash with a capacity of 2 . The compressor is a medium for transferring ash by using compressed air. The compressor used is a SCREEW OIL INJECTED SULLAIR LS20-150H compressor. Currently there is a decrease in performance on the compressor, which initially had a compression ratio of 1,600 Psia, polytropic head 14,500,599, capacity 10,938,438, flow rate 11,379,622 lb/s, efficiency 98.5%. After analyzing this compressor, the data obtained was a compression ratio of 1,540 Psia, polytropic head 13,805,166, capacity 10,950,733, flow rate 11,392,412, and efficiency of 95.3%. The reason is because the compressor room area does not have an active blower so that dirt/ash stuck to the radiator fins causes heat transfer to be hampered and this greatly affects the performance of the compressor parts to work optimally\",\"PeriodicalId\":17759,\"journal\":{\"name\":\"Jurnal Teknik Industri Terintegrasi\",\"volume\":\"18 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teknik Industri Terintegrasi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31004/jutin.v7i1.25494\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknik Industri Terintegrasi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31004/jutin.v7i1.25494","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analisis Kinerja Kompressor Screw Oil Injected Sullair Ls20-150h untuk Ash Handling (Study Kasus PLTU Teluk Sirih)
PLTU Teluk Sirih is a coal-fired steam power plant as an energy source that produces ash with a capacity of 2 . The compressor is a medium for transferring ash by using compressed air. The compressor used is a SCREEW OIL INJECTED SULLAIR LS20-150H compressor. Currently there is a decrease in performance on the compressor, which initially had a compression ratio of 1,600 Psia, polytropic head 14,500,599, capacity 10,938,438, flow rate 11,379,622 lb/s, efficiency 98.5%. After analyzing this compressor, the data obtained was a compression ratio of 1,540 Psia, polytropic head 13,805,166, capacity 10,950,733, flow rate 11,392,412, and efficiency of 95.3%. The reason is because the compressor room area does not have an active blower so that dirt/ash stuck to the radiator fins causes heat transfer to be hampered and this greatly affects the performance of the compressor parts to work optimally