{"title":"射频电感耦合等离子体中植入器源头的热分析","authors":"Chang-Won Jeong, Choong-Mo Ryu, Hee-Lak Lee, Jong Jin Hwang, Seung Jae Moon","doi":"10.1116/6.0003060","DOIUrl":null,"url":null,"abstract":"The inductively coupled plasma-ion implanter is a closed vacuum, and the temperature increase in the source head owing to plasma generation in the chamber was predicted by numerical simulation and verified via measurements. The heat generation of the source head inside the vacuum chamber was photographed using an infrared thermal-imaging camera and set as the main temperature boundary condition for analysis. The showerhead temperature was confirmed through thermocouple measurements to verify the simulation and ensure reliability. An error of less than 1% was obtained for the aperture and aperture cover. The simulation-analysis results and measured showerhead results obtained from the thermocouple equipment exhibited an error of less than 2%.","PeriodicalId":282302,"journal":{"name":"Journal of Vacuum Science & Technology B","volume":"115 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal analysis of implanter source head in radio-frequency inductively coupled plasma\",\"authors\":\"Chang-Won Jeong, Choong-Mo Ryu, Hee-Lak Lee, Jong Jin Hwang, Seung Jae Moon\",\"doi\":\"10.1116/6.0003060\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The inductively coupled plasma-ion implanter is a closed vacuum, and the temperature increase in the source head owing to plasma generation in the chamber was predicted by numerical simulation and verified via measurements. The heat generation of the source head inside the vacuum chamber was photographed using an infrared thermal-imaging camera and set as the main temperature boundary condition for analysis. The showerhead temperature was confirmed through thermocouple measurements to verify the simulation and ensure reliability. An error of less than 1% was obtained for the aperture and aperture cover. The simulation-analysis results and measured showerhead results obtained from the thermocouple equipment exhibited an error of less than 2%.\",\"PeriodicalId\":282302,\"journal\":{\"name\":\"Journal of Vacuum Science & Technology B\",\"volume\":\"115 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vacuum Science & Technology B\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1116/6.0003060\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vacuum Science & Technology B","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1116/6.0003060","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电感耦合等离子体离子注入器是一个封闭的真空装置,通过数值模拟预测了腔体内等离子体产生导致源头温度升高的情况,并通过测量进行了验证。使用红外热成像相机拍摄了真空室内源头的发热情况,并将其设定为分析的主要温度边界条件。通过热电偶测量确认喷淋头温度,以验证模拟并确保可靠性。孔径和孔径盖的误差小于 1%。模拟分析结果与通过热电偶设备获得的喷淋头测量结果的误差小于 2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal analysis of implanter source head in radio-frequency inductively coupled plasma
The inductively coupled plasma-ion implanter is a closed vacuum, and the temperature increase in the source head owing to plasma generation in the chamber was predicted by numerical simulation and verified via measurements. The heat generation of the source head inside the vacuum chamber was photographed using an infrared thermal-imaging camera and set as the main temperature boundary condition for analysis. The showerhead temperature was confirmed through thermocouple measurements to verify the simulation and ensure reliability. An error of less than 1% was obtained for the aperture and aperture cover. The simulation-analysis results and measured showerhead results obtained from the thermocouple equipment exhibited an error of less than 2%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信