{"title":"基于地下水地潮水位测量的自动水位计随机误差成分的比较估算","authors":"Taras Yu. Zavedy, Nikita R. Adonin, Oleg N. Kokorev, Alexander A. Shchipkov","doi":"10.18799/24131830/2024/2/4341","DOIUrl":null,"url":null,"abstract":"Relevance. Introduction of autonomous digital level gauges allows significantly expanding the range of tasks solved in various fields of geology and ecology, by increasing the frequency of measurements and applying mathematical processing methods to avoid distortions of different nature. The expansion of the field of application of downhole level meters makes it a topical issue to choose a particular type of device to ensure the required measurement accuracy. Aim. To consider the approaches to comparative estimation of random error of several types of automatic level gauges based on their recording of earth-tidal variations of groundwater level. Methods. Methods of compensating the influence of variations in atmospheric pressure on groundwater levels; methods of calculating tidal level variations; methods of correlation and frequency analysis of the calculated and experimental data. Results. The authors have carried out a comparative assessment of the accuracy in readings of several digital level gauges, installed in one well, by comparing the measured values of earth-tidal variations of the groundwater level with the calculated ones. Based on the experimental data, tidal variations of the groundwater level were obtained by eliminating distortions from variations in atmospheric pressure and then filtering with the moving mean. From correlation and amplitude-frequency analysis of the calculated and experimental data, indicators were determined for making a comparative assessment of a random component of the error of the tested level gauges. Conclusions. The approach suggested allows choosing independent digital level gauges with a minimum random error component using the totality of calculated parameters. The most promising way to eliminate the distorting effects of tidal variation of groundwater level is the method based on the cutter frequency filtering of the level signal measured by the level gauge.","PeriodicalId":513946,"journal":{"name":"Bulletin of the Tomsk Polytechnic University Geo Assets Engineering","volume":"83 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative estimation of a random error component of automatic well level gauges based on processing measurements of earth-tidal level of groundwater\",\"authors\":\"Taras Yu. Zavedy, Nikita R. Adonin, Oleg N. Kokorev, Alexander A. Shchipkov\",\"doi\":\"10.18799/24131830/2024/2/4341\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Relevance. Introduction of autonomous digital level gauges allows significantly expanding the range of tasks solved in various fields of geology and ecology, by increasing the frequency of measurements and applying mathematical processing methods to avoid distortions of different nature. The expansion of the field of application of downhole level meters makes it a topical issue to choose a particular type of device to ensure the required measurement accuracy. Aim. To consider the approaches to comparative estimation of random error of several types of automatic level gauges based on their recording of earth-tidal variations of groundwater level. Methods. Methods of compensating the influence of variations in atmospheric pressure on groundwater levels; methods of calculating tidal level variations; methods of correlation and frequency analysis of the calculated and experimental data. Results. The authors have carried out a comparative assessment of the accuracy in readings of several digital level gauges, installed in one well, by comparing the measured values of earth-tidal variations of the groundwater level with the calculated ones. Based on the experimental data, tidal variations of the groundwater level were obtained by eliminating distortions from variations in atmospheric pressure and then filtering with the moving mean. From correlation and amplitude-frequency analysis of the calculated and experimental data, indicators were determined for making a comparative assessment of a random component of the error of the tested level gauges. Conclusions. The approach suggested allows choosing independent digital level gauges with a minimum random error component using the totality of calculated parameters. The most promising way to eliminate the distorting effects of tidal variation of groundwater level is the method based on the cutter frequency filtering of the level signal measured by the level gauge.\",\"PeriodicalId\":513946,\"journal\":{\"name\":\"Bulletin of the Tomsk Polytechnic University Geo Assets Engineering\",\"volume\":\"83 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Tomsk Polytechnic University Geo Assets Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18799/24131830/2024/2/4341\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Tomsk Polytechnic University Geo Assets Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18799/24131830/2024/2/4341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

相关性。通过提高测量频率和应用数学处理方法来避免不同性质的失真,采用自主数字液位计可以显著扩大地质和生态学各领域的任务范围。随着井下液位计应用领域的扩大,如何选择特定类型的设备以确保所需的测量精度成为一个热门话题。目的根据自动水位计对地下水位潮汐变化的记录,研究几种自动水位计随机误差的比较估算方法。方法。补偿大气压力变化对地下水位影响的方法;潮汐水位变化的计算方法;计算和实验数据的相关性和频率分析方法。结果。作者通过比较地下水位潮汐变化的测量值和计算值,对安装在一口井中的几个数字水位计的读数精度进行了比较评估。根据实验数据,通过消除大气压力变化造成的失真,然后用移动平均值进行过滤,得到了地下水位的潮汐变化。通过对计算数据和实验数据的相关性和振幅频率分析,确定了对测试水位计误差的随机成分进行比较评估的指标。得出结论。根据所建议的方法,可以利用计算参数的整体性选择随机误差最小的独立数字液位计。消除地下水位潮汐变化扭曲影响的最有前途的方法是对水位计测量的水位信号进行切频滤波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative estimation of a random error component of automatic well level gauges based on processing measurements of earth-tidal level of groundwater
Relevance. Introduction of autonomous digital level gauges allows significantly expanding the range of tasks solved in various fields of geology and ecology, by increasing the frequency of measurements and applying mathematical processing methods to avoid distortions of different nature. The expansion of the field of application of downhole level meters makes it a topical issue to choose a particular type of device to ensure the required measurement accuracy. Aim. To consider the approaches to comparative estimation of random error of several types of automatic level gauges based on their recording of earth-tidal variations of groundwater level. Methods. Methods of compensating the influence of variations in atmospheric pressure on groundwater levels; methods of calculating tidal level variations; methods of correlation and frequency analysis of the calculated and experimental data. Results. The authors have carried out a comparative assessment of the accuracy in readings of several digital level gauges, installed in one well, by comparing the measured values of earth-tidal variations of the groundwater level with the calculated ones. Based on the experimental data, tidal variations of the groundwater level were obtained by eliminating distortions from variations in atmospheric pressure and then filtering with the moving mean. From correlation and amplitude-frequency analysis of the calculated and experimental data, indicators were determined for making a comparative assessment of a random component of the error of the tested level gauges. Conclusions. The approach suggested allows choosing independent digital level gauges with a minimum random error component using the totality of calculated parameters. The most promising way to eliminate the distorting effects of tidal variation of groundwater level is the method based on the cutter frequency filtering of the level signal measured by the level gauge.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信