Agus Sukoco Heru Sumarno, Eka Mandayatma, Doni Radianto, Imam Saukani
{"title":"将称重传感器作为膝关节功能障碍康复工具的一个组成部分","authors":"Agus Sukoco Heru Sumarno, Eka Mandayatma, Doni Radianto, Imam Saukani","doi":"10.33795/elposys.v11i1.4625","DOIUrl":null,"url":null,"abstract":"Knee joint fractures caused after surgery or other activities that cause knee dysfunction require a rehabilitation process. Knee dysfunction means the knee joint cannot be bent/moved at the desired angle. Because the function of the knee is so important in relation to human activities, it is necessary to immediately carry out rehabilitation measures for a perfect return. Rehabilitation in this case can be done with weight training. In this research, loading for rehabilitation will be designed using load cell-based electronic engineering for the desired load, because the equipment used so far works manually.The research began with inventorying component requirements, designing the circuit, compiling a process algorithm, functional testing, calibration and data collection. The research data is a function of weight on movement, in this case motorbikes. The output of the research is a control circuit prototype to regulate load-based motor movement.The equipment specifications are produced with a loading capacity limit of 5 kg with a change step of 250 grams.","PeriodicalId":476257,"journal":{"name":"Elposys: Jurnal Sistem Kelistrikan","volume":"76 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Implementasi Load Cell sebagai komponen Alat Rehabilitasi Disfungsi Sendi Lutut\",\"authors\":\"Agus Sukoco Heru Sumarno, Eka Mandayatma, Doni Radianto, Imam Saukani\",\"doi\":\"10.33795/elposys.v11i1.4625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Knee joint fractures caused after surgery or other activities that cause knee dysfunction require a rehabilitation process. Knee dysfunction means the knee joint cannot be bent/moved at the desired angle. Because the function of the knee is so important in relation to human activities, it is necessary to immediately carry out rehabilitation measures for a perfect return. Rehabilitation in this case can be done with weight training. In this research, loading for rehabilitation will be designed using load cell-based electronic engineering for the desired load, because the equipment used so far works manually.The research began with inventorying component requirements, designing the circuit, compiling a process algorithm, functional testing, calibration and data collection. The research data is a function of weight on movement, in this case motorbikes. The output of the research is a control circuit prototype to regulate load-based motor movement.The equipment specifications are produced with a loading capacity limit of 5 kg with a change step of 250 grams.\",\"PeriodicalId\":476257,\"journal\":{\"name\":\"Elposys: Jurnal Sistem Kelistrikan\",\"volume\":\"76 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Elposys: Jurnal Sistem Kelistrikan\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.33795/elposys.v11i1.4625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elposys: Jurnal Sistem Kelistrikan","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.33795/elposys.v11i1.4625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Implementasi Load Cell sebagai komponen Alat Rehabilitasi Disfungsi Sendi Lutut
Knee joint fractures caused after surgery or other activities that cause knee dysfunction require a rehabilitation process. Knee dysfunction means the knee joint cannot be bent/moved at the desired angle. Because the function of the knee is so important in relation to human activities, it is necessary to immediately carry out rehabilitation measures for a perfect return. Rehabilitation in this case can be done with weight training. In this research, loading for rehabilitation will be designed using load cell-based electronic engineering for the desired load, because the equipment used so far works manually.The research began with inventorying component requirements, designing the circuit, compiling a process algorithm, functional testing, calibration and data collection. The research data is a function of weight on movement, in this case motorbikes. The output of the research is a control circuit prototype to regulate load-based motor movement.The equipment specifications are produced with a loading capacity limit of 5 kg with a change step of 250 grams.