Anthony J. Kanelidis , AbdulRahman Abutaleb , Sara Kalantari , Jonathan Grinstein , Atman P. Shah
{"title":"使用大型有盖支架经皮介入治疗 HeartMate 3 外流移植物阻塞","authors":"Anthony J. Kanelidis , AbdulRahman Abutaleb , Sara Kalantari , Jonathan Grinstein , Atman P. Shah","doi":"10.1016/j.crmic.2024.100019","DOIUrl":null,"url":null,"abstract":"<div><p>A patient with a HeartMate 3 left ventricular assist device complicated by an extrinsic outflow graft obstruction was treated with a percutaneous approach using large covered stents in overlapping fashion from the proximal portion of the outflow graft at the bend relief into the LVAD rotor.</p></div>","PeriodicalId":100217,"journal":{"name":"Cardiovascular Revascularization Medicine: Interesting Cases","volume":"2 ","pages":"Article 100019"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2950275624000157/pdfft?md5=31519580f02c71b311574d3702c400fc&pid=1-s2.0-S2950275624000157-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Percutaneous intervention of a HeartMate 3 extrinsic outflow graft obstruction using large covered stents\",\"authors\":\"Anthony J. Kanelidis , AbdulRahman Abutaleb , Sara Kalantari , Jonathan Grinstein , Atman P. Shah\",\"doi\":\"10.1016/j.crmic.2024.100019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A patient with a HeartMate 3 left ventricular assist device complicated by an extrinsic outflow graft obstruction was treated with a percutaneous approach using large covered stents in overlapping fashion from the proximal portion of the outflow graft at the bend relief into the LVAD rotor.</p></div>\",\"PeriodicalId\":100217,\"journal\":{\"name\":\"Cardiovascular Revascularization Medicine: Interesting Cases\",\"volume\":\"2 \",\"pages\":\"Article 100019\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2950275624000157/pdfft?md5=31519580f02c71b311574d3702c400fc&pid=1-s2.0-S2950275624000157-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Revascularization Medicine: Interesting Cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2950275624000157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Revascularization Medicine: Interesting Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950275624000157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Percutaneous intervention of a HeartMate 3 extrinsic outflow graft obstruction using large covered stents
A patient with a HeartMate 3 left ventricular assist device complicated by an extrinsic outflow graft obstruction was treated with a percutaneous approach using large covered stents in overlapping fashion from the proximal portion of the outflow graft at the bend relief into the LVAD rotor.