热电测试下的多点接触模拟

Q3 Engineering
Soldatov A.A
{"title":"热电测试下的多点接触模拟","authors":"Soldatov A.A","doi":"10.31489/2024no1/93-103","DOIUrl":null,"url":null,"abstract":"The article presents the results of modeling a multipoint contact in the thermoelectric method of testing. Sources of thermoelectromotive force (thermoEMF) have shown different influences, according to their type, on the load characteristics of the equivalent source obtained by parallel connection of several thermocouples as shown in the explanatory figures. The presented model is implemented in the NI LabVIEW package, which is freely available. The model was verified on three types of thermocouples (copper-constantan, copper-nichrome, and chromel-alumel), which have been connected in parallel in different quantities. The calculated load characteristics of the equivalent sources differ from the experimental ones by no more than 6%. The results of modeling the load characteristics of the equivalent thermoEMF sources obtained by parallel connection of different quantities of two types of thermocouples are presented. It is shown that in order to obtain reliable data, it is necessary to provide an equivalent source load of at least 1 kOhm.","PeriodicalId":11789,"journal":{"name":"Eurasian Physical Technical Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SIMULATION OF MULTIPOINT CONTACT UNDER THERMOELECTRIC TESTING\",\"authors\":\"Soldatov A.A\",\"doi\":\"10.31489/2024no1/93-103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents the results of modeling a multipoint contact in the thermoelectric method of testing. Sources of thermoelectromotive force (thermoEMF) have shown different influences, according to their type, on the load characteristics of the equivalent source obtained by parallel connection of several thermocouples as shown in the explanatory figures. The presented model is implemented in the NI LabVIEW package, which is freely available. The model was verified on three types of thermocouples (copper-constantan, copper-nichrome, and chromel-alumel), which have been connected in parallel in different quantities. The calculated load characteristics of the equivalent sources differ from the experimental ones by no more than 6%. The results of modeling the load characteristics of the equivalent thermoEMF sources obtained by parallel connection of different quantities of two types of thermocouples are presented. It is shown that in order to obtain reliable data, it is necessary to provide an equivalent source load of at least 1 kOhm.\",\"PeriodicalId\":11789,\"journal\":{\"name\":\"Eurasian Physical Technical Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eurasian Physical Technical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31489/2024no1/93-103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurasian Physical Technical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31489/2024no1/93-103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

文章介绍了热电测试法中多点接触建模的结果。热电动势(thermoEMF)源的类型不同,对通过并联多个热电偶获得的等效源的负载特性的影响也不同,如注释图所示。所介绍的模型是在免费提供的 NI LabVIEW 软件包中实现的。该模型在三种类型的热电偶(铜-康铜、铜-铬和铬-铝)上进行了验证,这些热电偶以不同数量并联。计算得出的等效源负载特性与实验结果相差不超过 6%。本文介绍了通过并联不同数量的两种热电偶而获得的等效热电偶源的负载特性建模结果。结果表明,为了获得可靠的数据,必须提供至少 1 千欧的等效源负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SIMULATION OF MULTIPOINT CONTACT UNDER THERMOELECTRIC TESTING
The article presents the results of modeling a multipoint contact in the thermoelectric method of testing. Sources of thermoelectromotive force (thermoEMF) have shown different influences, according to their type, on the load characteristics of the equivalent source obtained by parallel connection of several thermocouples as shown in the explanatory figures. The presented model is implemented in the NI LabVIEW package, which is freely available. The model was verified on three types of thermocouples (copper-constantan, copper-nichrome, and chromel-alumel), which have been connected in parallel in different quantities. The calculated load characteristics of the equivalent sources differ from the experimental ones by no more than 6%. The results of modeling the load characteristics of the equivalent thermoEMF sources obtained by parallel connection of different quantities of two types of thermocouples are presented. It is shown that in order to obtain reliable data, it is necessary to provide an equivalent source load of at least 1 kOhm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
15
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信