{"title":"经验丰富的儿科脊柱畸形外科医生利用机器人辅助手术导航为 334 名患者连续植入 5070 枚椎弓根螺钉的分析:儿科脊柱后路融合术的手术安全性和早期围手术期并发症。","authors":"Roger F Widmann, Jenna L Wisch, Olivia C Tracey, Colson P Zucker, Tyler Feddema, Florian Miller, Gabriel S Linden, Mark Erickson, Jessica H Heyer","doi":"10.1007/s43390-024-00854-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluates the intraoperative and short-term complications associated with robotically assisted pedicle screw placement in pediatric posterior spinal fusion (PSF) from three surgeons at two different institutions.</p><p><strong>Methods: </strong>We retrospectively reviewed 334 pediatric patients who underwent PSF with robotic-assisted navigation at 2 institutions over 3 years (2020-2022). Five thousand seventy robotically placed screws were evaluated. Data collection focused on intraoperative and early postoperative complications with minimum 30-day follow-up. Patients undergoing revision procedures were excluded.</p><p><strong>Results: </strong>Intraoperative complications included 1 durotomy, 6 patients with neuromonitoring alerts not related to screw placement, and 62 screws (1.2%) with documented pedicle breaches, all of which were revised at time of surgery. By quartile, pedicle breaches statistically declined from first quartile to fourth quartile (1.8% vs. 0.56%, p < 0.05). No breach was associated with neuromonitoring changes or neurological sequelae. No spinal cord or vascular injuries occurred. Seventeen postoperative complications occurred in eleven (3.3%) of patients. There were five (1.5%) patients with unplanned return to the operating room.</p><p><strong>Conclusion: </strong>Robotically assisted pedicle screw placement was safely and reliably performed on pediatric spinal deformity by three surgeons across two centers, demonstrating an acceptable safety profile and low incidence of unplanned return to the operating room.</p>","PeriodicalId":21796,"journal":{"name":"Spine deformity","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of 5,070 consecutive pedicle screws placed utilizing robotically assisted surgical navigation in 334 patients by experienced pediatric spine deformity surgeons: surgical safety and early perioperative complications in pediatric posterior spinal fusion.\",\"authors\":\"Roger F Widmann, Jenna L Wisch, Olivia C Tracey, Colson P Zucker, Tyler Feddema, Florian Miller, Gabriel S Linden, Mark Erickson, Jessica H Heyer\",\"doi\":\"10.1007/s43390-024-00854-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study evaluates the intraoperative and short-term complications associated with robotically assisted pedicle screw placement in pediatric posterior spinal fusion (PSF) from three surgeons at two different institutions.</p><p><strong>Methods: </strong>We retrospectively reviewed 334 pediatric patients who underwent PSF with robotic-assisted navigation at 2 institutions over 3 years (2020-2022). Five thousand seventy robotically placed screws were evaluated. Data collection focused on intraoperative and early postoperative complications with minimum 30-day follow-up. Patients undergoing revision procedures were excluded.</p><p><strong>Results: </strong>Intraoperative complications included 1 durotomy, 6 patients with neuromonitoring alerts not related to screw placement, and 62 screws (1.2%) with documented pedicle breaches, all of which were revised at time of surgery. By quartile, pedicle breaches statistically declined from first quartile to fourth quartile (1.8% vs. 0.56%, p < 0.05). No breach was associated with neuromonitoring changes or neurological sequelae. No spinal cord or vascular injuries occurred. Seventeen postoperative complications occurred in eleven (3.3%) of patients. There were five (1.5%) patients with unplanned return to the operating room.</p><p><strong>Conclusion: </strong>Robotically assisted pedicle screw placement was safely and reliably performed on pediatric spinal deformity by three surgeons across two centers, demonstrating an acceptable safety profile and low incidence of unplanned return to the operating room.</p>\",\"PeriodicalId\":21796,\"journal\":{\"name\":\"Spine deformity\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spine deformity\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s43390-024-00854-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine deformity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s43390-024-00854-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究评估了两家不同机构的三位外科医生在小儿脊柱后路融合术(PSF)中使用机器人辅助椎弓根螺钉置入术的术中和短期并发症:我们回顾性研究了334例小儿患者,这些患者在3年(2020-2022年)内接受了两家机构的机器人辅助导航脊柱后路融合术。共评估了 570 例机器人置入螺钉的患者。数据收集的重点是术中和术后早期并发症,至少随访30天。接受翻修手术的患者不包括在内:术中并发症包括1例硬膜外切开术、6例神经监测警报与螺钉置入无关的患者,以及62例螺钉(1.2%)有记录的椎弓根破损,所有这些患者在手术时都进行了翻修。从四分位数来看,椎弓根破损率从第一四分位数到第四四分位数呈统计学下降趋势(1.8% vs. 0.56%,p 结论:机器人辅助椎弓根螺钉置入术是一种有效的治疗方法:机器人辅助椎弓根螺钉置入术是由两个中心的三位外科医生对小儿脊柱畸形进行的安全可靠的手术,具有可接受的安全性和较低的意外返回手术室发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of 5,070 consecutive pedicle screws placed utilizing robotically assisted surgical navigation in 334 patients by experienced pediatric spine deformity surgeons: surgical safety and early perioperative complications in pediatric posterior spinal fusion.

Purpose: This study evaluates the intraoperative and short-term complications associated with robotically assisted pedicle screw placement in pediatric posterior spinal fusion (PSF) from three surgeons at two different institutions.

Methods: We retrospectively reviewed 334 pediatric patients who underwent PSF with robotic-assisted navigation at 2 institutions over 3 years (2020-2022). Five thousand seventy robotically placed screws were evaluated. Data collection focused on intraoperative and early postoperative complications with minimum 30-day follow-up. Patients undergoing revision procedures were excluded.

Results: Intraoperative complications included 1 durotomy, 6 patients with neuromonitoring alerts not related to screw placement, and 62 screws (1.2%) with documented pedicle breaches, all of which were revised at time of surgery. By quartile, pedicle breaches statistically declined from first quartile to fourth quartile (1.8% vs. 0.56%, p < 0.05). No breach was associated with neuromonitoring changes or neurological sequelae. No spinal cord or vascular injuries occurred. Seventeen postoperative complications occurred in eleven (3.3%) of patients. There were five (1.5%) patients with unplanned return to the operating room.

Conclusion: Robotically assisted pedicle screw placement was safely and reliably performed on pediatric spinal deformity by three surgeons across two centers, demonstrating an acceptable safety profile and low incidence of unplanned return to the operating room.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.20
自引率
18.80%
发文量
167
期刊介绍: Spine Deformity the official journal of the?Scoliosis Research Society is a peer-refereed publication to disseminate knowledge on basic science and clinical research into the?etiology?biomechanics?treatment?methods and outcomes of all types of?spinal deformities. The international members of the Editorial Board provide a worldwide perspective for the journal's area of interest.The?journal?will enhance the mission of the Society which is to foster the optimal care of all patients with?spine?deformities worldwide. Articles published in?Spine Deformity?are Medline indexed in PubMed.? The journal publishes original articles in the form of clinical and basic research. Spine Deformity will only publish studies that have institutional review board (IRB) or similar ethics committee approval for human and animal studies and have strictly observed these guidelines. The minimum follow-up period for follow-up clinical studies is 24 months.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信