D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik
{"title":"用于分析水中重金属阳离子含量的电容式传感器的聚甲基丙烯酸甲酯传感层","authors":"D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik","doi":"10.29235/1561-8331-2024-60-1-81-88","DOIUrl":null,"url":null,"abstract":"The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.","PeriodicalId":20798,"journal":{"name":"Proceedings of the National Academy of Sciences of Belarus, Chemical Series","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensory layers of poly(methyl metacrylate) for capacitive sensors for analysis of the content of heavy metal cations in water\",\"authors\":\"D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik\",\"doi\":\"10.29235/1561-8331-2024-60-1-81-88\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.\",\"PeriodicalId\":20798,\"journal\":{\"name\":\"Proceedings of the National Academy of Sciences of Belarus, Chemical Series\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the National Academy of Sciences of Belarus, Chemical Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29235/1561-8331-2024-60-1-81-88\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the National Academy of Sciences of Belarus, Chemical Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29235/1561-8331-2024-60-1-81-88","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
Sensory layers of poly(methyl metacrylate) for capacitive sensors for analysis of the content of heavy metal cations in water
The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.