用于分析水中重金属阳离子含量的电容式传感器的聚甲基丙烯酸甲酯传感层

Q4 Chemistry
D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik
{"title":"用于分析水中重金属阳离子含量的电容式传感器的聚甲基丙烯酸甲酯传感层","authors":"D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik","doi":"10.29235/1561-8331-2024-60-1-81-88","DOIUrl":null,"url":null,"abstract":"The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.","PeriodicalId":20798,"journal":{"name":"Proceedings of the National Academy of Sciences of Belarus, Chemical Series","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensory layers of poly(methyl metacrylate) for capacitive sensors for analysis of the content of heavy metal cations in water\",\"authors\":\"D. V. Sapsaliou, G. Melnikova, A. V. Aksiuchyts, T. Tolstaya, D. A. Kotov, S. Chizhik\",\"doi\":\"10.29235/1561-8331-2024-60-1-81-88\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.\",\"PeriodicalId\":20798,\"journal\":{\"name\":\"Proceedings of the National Academy of Sciences of Belarus, Chemical Series\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the National Academy of Sciences of Belarus, Chemical Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29235/1561-8331-2024-60-1-81-88\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the National Academy of Sciences of Belarus, Chemical Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29235/1561-8331-2024-60-1-81-88","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了使用聚(甲基丙烯酸甲酯)涂层开发用于分析水中重金属含量(以 Ni2+ 离子为例)的电容式传感器的成果。原子力显微镜研究了形成的导电镍层和纳米结构聚(甲基丙烯酸甲酯)薄膜的结构和形态特征。根据对原始传感器的电容特性在不同浓度的 Ni2+ 离子下对频率的依赖性分析,确定了传感器的以下工作特性:响应时间 - 5 分钟;Ni2+ 离子浓度的工作范围:1 ‧ 10-3-50 mM;检测下限 ≈ 0.06 mg/l。实验表明,通过旋涂法在导电镍层上形成聚(甲基丙烯酸甲酯)涂层,可将传感器的使用寿命延长至八个周期,同时保持传感器的灵敏度水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensory layers of poly(methyl metacrylate) for capacitive sensors for analysis of the content of heavy metal cations in water
The results of using poly(methyl methacrylate) coatings for the development of the capacitive sensors for analyzing the content of heavy metals in water (using Ni2+ ions as example) are presented. Structural and morphological characteristics of the formed conductive nickel layer and nanostructured poly(methyl methacrylate) films were studied by atomic force microscopy. Based on the analysis of the dependence of the capacitive characteristics of the original sensor on the frequency at different concentrations of Ni2+ ions, the following operating characteristics of the sensor were established: response time – 5 min; operating range of Ni2+ ion concentrations: 1 ‧ 10–3–50 mM; lower detection limit ≈ 0,06 mg/l. It is shown that the formation of a poly(methyl methacrylate) coating on a conductive nickel layer by the spin coating method increases the service life of the sensor to eight cycles while maintaining the level of sensor sensitivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信