核磁共振成像室病人转运装置的创新设计与实验研究

Q4 Engineering
Lingfeng Sang, Shichuang Liu, Hongbo Wang, Zhengcai Wang, Yu Tian, L. Vlădăreanu
{"title":"核磁共振成像室病人转运装置的创新设计与实验研究","authors":"Lingfeng Sang, Shichuang Liu, Hongbo Wang, Zhengcai Wang, Yu Tian, L. Vlădăreanu","doi":"10.2174/0122127976303062240222115541","DOIUrl":null,"url":null,"abstract":"\n\nPatient Transfer Apparatus (PTA), which has been reported by various\nrelevant papers and patents, is widely used in the hospital. However, there are few corresponding\ntransfer apparatuses for research and development in the nuclear magnetic resonance imaging\n(MRI) room because of the influence of a high magnetic field environment. It is desired to require\nthe apparatus for the patient and the medical staff to have weak magnetism, high matching, and\neasy operation, etc\n\n\n\nThe purpose of this study is to find out the working principle of PTA, to conduct parameter optimization and design and develop more effective PTA for the application of the MRI room.\n\n\n\nFirstly, based on the patient transfer process, a novel transfer model with the coordinated\nmovement of the transfer belt and the moving panel is proposed, the corresponding clutch mechanism is conceived and the working principle of the whole mechanism movement is designed and\nanalyzed in detail. Secondly, the force analysis of the clutch mechanism, lifting mechanism and patient transfer mechanism are performed, the mechanical structures are optimized, and the optimal\nsizes are obtained. Thirdly, the mechanical structure of the system is designed in detail, and the\nprototype is manufactured.\n\n\n\nFinally, the performance evaluation of the system is conducted by means of the fuzzy\nevaluation method and clinical study. The results showed that the motion function of the apparatus\nis reasonable and it can work normally in the MRI room, the comfort of the PTA is also excellent.\nThe research results also prove the accuracy of the working principle and the rationality of the\nstructural design\n\n\n\nThe non-magnetic PTA is suitable for quickly transferring patients who are unable to\nmove in the MRI room of a hospital by the manual method\n","PeriodicalId":39169,"journal":{"name":"Recent Patents on Mechanical Engineering","volume":"21 8","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Innovative Design and Experimental Research of the Patient Transfer\\nApparatus for MRI Room\",\"authors\":\"Lingfeng Sang, Shichuang Liu, Hongbo Wang, Zhengcai Wang, Yu Tian, L. Vlădăreanu\",\"doi\":\"10.2174/0122127976303062240222115541\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n\\nPatient Transfer Apparatus (PTA), which has been reported by various\\nrelevant papers and patents, is widely used in the hospital. However, there are few corresponding\\ntransfer apparatuses for research and development in the nuclear magnetic resonance imaging\\n(MRI) room because of the influence of a high magnetic field environment. It is desired to require\\nthe apparatus for the patient and the medical staff to have weak magnetism, high matching, and\\neasy operation, etc\\n\\n\\n\\nThe purpose of this study is to find out the working principle of PTA, to conduct parameter optimization and design and develop more effective PTA for the application of the MRI room.\\n\\n\\n\\nFirstly, based on the patient transfer process, a novel transfer model with the coordinated\\nmovement of the transfer belt and the moving panel is proposed, the corresponding clutch mechanism is conceived and the working principle of the whole mechanism movement is designed and\\nanalyzed in detail. Secondly, the force analysis of the clutch mechanism, lifting mechanism and patient transfer mechanism are performed, the mechanical structures are optimized, and the optimal\\nsizes are obtained. Thirdly, the mechanical structure of the system is designed in detail, and the\\nprototype is manufactured.\\n\\n\\n\\nFinally, the performance evaluation of the system is conducted by means of the fuzzy\\nevaluation method and clinical study. The results showed that the motion function of the apparatus\\nis reasonable and it can work normally in the MRI room, the comfort of the PTA is also excellent.\\nThe research results also prove the accuracy of the working principle and the rationality of the\\nstructural design\\n\\n\\n\\nThe non-magnetic PTA is suitable for quickly transferring patients who are unable to\\nmove in the MRI room of a hospital by the manual method\\n\",\"PeriodicalId\":39169,\"journal\":{\"name\":\"Recent Patents on Mechanical Engineering\",\"volume\":\"21 8\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Recent Patents on Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/0122127976303062240222115541\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Patents on Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0122127976303062240222115541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

病人转运装置(PTA)已被各种相关论文和专利所报道,在医院中得到广泛应用。然而,在核磁共振成像(MRI)室中,由于受到高磁场环境的影响,很少有相应的转移装置可供研发。本研究的目的是找出 PTA 的工作原理,进行参数优化和设计,开发出更有效的 PTA,以应用于核磁共振成像室。首先,根据病人的转移过程,提出了转移带和移动面板协调运动的新型转移模型,构思了相应的离合器机构,并详细设计和分析了整个机构运动的工作原理。其次,对离合器机构、升降机构和病人转运机构进行受力分析,优化机械结构,获得最优化尺寸。最后,通过模糊评价法和临床研究对系统进行了性能评价。研究结果还证明了工作原理的准确性和结构设计的合理性。无磁 PTA 适用于在医院核磁共振室中用人工方法快速转移无法移动的病人。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Innovative Design and Experimental Research of the Patient Transfer Apparatus for MRI Room
Patient Transfer Apparatus (PTA), which has been reported by various relevant papers and patents, is widely used in the hospital. However, there are few corresponding transfer apparatuses for research and development in the nuclear magnetic resonance imaging (MRI) room because of the influence of a high magnetic field environment. It is desired to require the apparatus for the patient and the medical staff to have weak magnetism, high matching, and easy operation, etc The purpose of this study is to find out the working principle of PTA, to conduct parameter optimization and design and develop more effective PTA for the application of the MRI room. Firstly, based on the patient transfer process, a novel transfer model with the coordinated movement of the transfer belt and the moving panel is proposed, the corresponding clutch mechanism is conceived and the working principle of the whole mechanism movement is designed and analyzed in detail. Secondly, the force analysis of the clutch mechanism, lifting mechanism and patient transfer mechanism are performed, the mechanical structures are optimized, and the optimal sizes are obtained. Thirdly, the mechanical structure of the system is designed in detail, and the prototype is manufactured. Finally, the performance evaluation of the system is conducted by means of the fuzzy evaluation method and clinical study. The results showed that the motion function of the apparatus is reasonable and it can work normally in the MRI room, the comfort of the PTA is also excellent. The research results also prove the accuracy of the working principle and the rationality of the structural design The non-magnetic PTA is suitable for quickly transferring patients who are unable to move in the MRI room of a hospital by the manual method
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Recent Patents on Mechanical Engineering
Recent Patents on Mechanical Engineering Engineering-Mechanical Engineering
CiteScore
0.80
自引率
0.00%
发文量
48
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信