{"title":"使用线圈栓塞治疗导管消融过程中的椎动脉先天性损伤。","authors":"Tsukasa Oshima, Kenichiro Yamagata, Yu Shimizu, Satoshi Koizumi, Katsuhito Fujiu, Issei Komuro","doi":"10.1111/pace.14970","DOIUrl":null,"url":null,"abstract":"<p><p>The internal jugular vein (IJV) is occasionally used for blood access during catheter ablation. Additionally, accidental injury of the vertebral artery during an IJV puncture is a rare complication that can result in catastrophic events, such as death. However, vascular access complications cannot be completely prevented despite the introduction of ultrasound-guided punctures. Here, we present a case of a patient with symptomatic paroxysmal atrial fibrillation that required catheter ablation.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Iatrogenic vertebral artery injury during catheter ablation treated using coil embolization.\",\"authors\":\"Tsukasa Oshima, Kenichiro Yamagata, Yu Shimizu, Satoshi Koizumi, Katsuhito Fujiu, Issei Komuro\",\"doi\":\"10.1111/pace.14970\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The internal jugular vein (IJV) is occasionally used for blood access during catheter ablation. Additionally, accidental injury of the vertebral artery during an IJV puncture is a rare complication that can result in catastrophic events, such as death. However, vascular access complications cannot be completely prevented despite the introduction of ultrasound-guided punctures. Here, we present a case of a patient with symptomatic paroxysmal atrial fibrillation that required catheter ablation.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.14970\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.14970","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Iatrogenic vertebral artery injury during catheter ablation treated using coil embolization.
The internal jugular vein (IJV) is occasionally used for blood access during catheter ablation. Additionally, accidental injury of the vertebral artery during an IJV puncture is a rare complication that can result in catastrophic events, such as death. However, vascular access complications cannot be completely prevented despite the introduction of ultrasound-guided punctures. Here, we present a case of a patient with symptomatic paroxysmal atrial fibrillation that required catheter ablation.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.