冠状动脉旁路移植手术后的连续血糖监测系统:可行性研究

IF 0.7 Q3 Medicine
ASIAN CARDIOVASCULAR & THORACIC ANNALS Pub Date : 2024-05-01 Epub Date: 2024-03-20 DOI:10.1177/02184923241240035
Tiziano Torre, Hervé Schlotterbeck, Francesco Ferraro, Catherine Klersy, Giuseppina Surace, Francesca Toto, Alberto Pozzoli, Enrico Ferrari, Stefanos Demertzis
{"title":"冠状动脉旁路移植手术后的连续血糖监测系统:可行性研究","authors":"Tiziano Torre, Hervé Schlotterbeck, Francesco Ferraro, Catherine Klersy, Giuseppina Surace, Francesca Toto, Alberto Pozzoli, Enrico Ferrari, Stefanos Demertzis","doi":"10.1177/02184923241240035","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Blood glucose level variability has been associated with increased risk of complication in the postoperative setting of cardiovascular surgery. Although interesting for optimization of blood glucose management in this context, continuous blood glucose (CBG) devices can have a limited reliability in this context, in particular because of the use of paracetamol. The aim of this study was to evaluate the reliability of Dexcom G6®, a recently developed continuous glucose monitoring device.</p><p><strong>Methods: </strong>We performed a prospective, observational, non-randomized, single-centre study comparing Dexcom G6® CBG level monitoring with the standard methods routinely used in this context. The standard blood glucose values were paired to the time corresponding values measured with Dexcom G6®. Agreement between the two methods and potential correlation in case of paracetamol use were calculated.</p><p><strong>Results: </strong>From May 2020 to August 2021, 36 out of 206 patients operated for isolated coronary artery bypass grafting were enrolled; 673 paired blood glucose level were analyzed. Global agreement (ρc) was 0.85 (95% C.I.: 0.84-0.86), intensive care unit agreement was 0.78 (95%C.I.: 0.74-0.82) and ward agreement was 0.91 (95%C.I.: 0.89-0.93). In the diabetic population, it was 0.87 (95%C.I.: 0.85-0.90). When paracetamol was used, the difference was 0.02 mmol/l (95%C.I.: 0.29-0.33).</p><p><strong>Conclusions: </strong>Dexcom G6<sup>®</sup> provides good blood glucose level accuracy in the postoperative context of cardiac surgery compared to the standard methods of measurements. The results are particularly reliable in the ward where the need for repeated capillary glucose measurements implies patient discomfort and time-consuming manipulations for the nursing staff.</p>","PeriodicalId":35950,"journal":{"name":"ASIAN CARDIOVASCULAR & THORACIC ANNALS","volume":" ","pages":"179-185"},"PeriodicalIF":0.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study.\",\"authors\":\"Tiziano Torre, Hervé Schlotterbeck, Francesco Ferraro, Catherine Klersy, Giuseppina Surace, Francesca Toto, Alberto Pozzoli, Enrico Ferrari, Stefanos Demertzis\",\"doi\":\"10.1177/02184923241240035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Blood glucose level variability has been associated with increased risk of complication in the postoperative setting of cardiovascular surgery. Although interesting for optimization of blood glucose management in this context, continuous blood glucose (CBG) devices can have a limited reliability in this context, in particular because of the use of paracetamol. The aim of this study was to evaluate the reliability of Dexcom G6®, a recently developed continuous glucose monitoring device.</p><p><strong>Methods: </strong>We performed a prospective, observational, non-randomized, single-centre study comparing Dexcom G6® CBG level monitoring with the standard methods routinely used in this context. The standard blood glucose values were paired to the time corresponding values measured with Dexcom G6®. Agreement between the two methods and potential correlation in case of paracetamol use were calculated.</p><p><strong>Results: </strong>From May 2020 to August 2021, 36 out of 206 patients operated for isolated coronary artery bypass grafting were enrolled; 673 paired blood glucose level were analyzed. Global agreement (ρc) was 0.85 (95% C.I.: 0.84-0.86), intensive care unit agreement was 0.78 (95%C.I.: 0.74-0.82) and ward agreement was 0.91 (95%C.I.: 0.89-0.93). In the diabetic population, it was 0.87 (95%C.I.: 0.85-0.90). When paracetamol was used, the difference was 0.02 mmol/l (95%C.I.: 0.29-0.33).</p><p><strong>Conclusions: </strong>Dexcom G6<sup>®</sup> provides good blood glucose level accuracy in the postoperative context of cardiac surgery compared to the standard methods of measurements. The results are particularly reliable in the ward where the need for repeated capillary glucose measurements implies patient discomfort and time-consuming manipulations for the nursing staff.</p>\",\"PeriodicalId\":35950,\"journal\":{\"name\":\"ASIAN CARDIOVASCULAR & THORACIC ANNALS\",\"volume\":\" \",\"pages\":\"179-185\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASIAN CARDIOVASCULAR & THORACIC ANNALS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/02184923241240035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASIAN CARDIOVASCULAR & THORACIC ANNALS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/02184923241240035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:血糖水平的变化与心血管手术术后并发症风险的增加有关。虽然在这种情况下优化血糖管理很有意义,但在这种情况下连续血糖监测设备的可靠性有限,特别是在使用扑热息痛的情况下。本研究旨在评估最近开发的连续血糖监测设备 Dexcom G6® 的可靠性:我们进行了一项前瞻性、观察性、非随机、单中心研究,将 Dexcom G6® CBG 水平监测与在这种情况下常规使用的标准方法进行比较。标准血糖值与 Dexcom G6® 测量的时间对应值配对。计算了两种方法之间的一致性以及在使用扑热息痛的情况下可能存在的相关性:从 2020 年 5 月到 2021 年 8 月,在 206 名接受孤立冠状动脉旁路移植手术的患者中,有 36 人接受了治疗;对 673 个配对血糖值进行了分析。全球一致性(ρc)为 0.85(95% C.I.:0.84-0.86),重症监护室一致性为 0.78(95% C.I.:0.74-0.82),病房一致性为 0.91(95% C.I.:0.89-0.93)。在糖尿病患者群体中,一致性为 0.87 (95%C.I.: 0.85-0.90)。使用扑热息痛时,差异为 0.02 mmol/l(95%C.I.:0.29-0.33):结论:与标准测量方法相比,Dexcom G6® 可为心脏手术术后血糖水平提供良好的准确性。其结果在病房中尤为可靠,因为在病房中需要反复测量毛细血管血糖,这意味着病人会感到不适,护理人员的操作也很耗时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study.

Background: Blood glucose level variability has been associated with increased risk of complication in the postoperative setting of cardiovascular surgery. Although interesting for optimization of blood glucose management in this context, continuous blood glucose (CBG) devices can have a limited reliability in this context, in particular because of the use of paracetamol. The aim of this study was to evaluate the reliability of Dexcom G6®, a recently developed continuous glucose monitoring device.

Methods: We performed a prospective, observational, non-randomized, single-centre study comparing Dexcom G6® CBG level monitoring with the standard methods routinely used in this context. The standard blood glucose values were paired to the time corresponding values measured with Dexcom G6®. Agreement between the two methods and potential correlation in case of paracetamol use were calculated.

Results: From May 2020 to August 2021, 36 out of 206 patients operated for isolated coronary artery bypass grafting were enrolled; 673 paired blood glucose level were analyzed. Global agreement (ρc) was 0.85 (95% C.I.: 0.84-0.86), intensive care unit agreement was 0.78 (95%C.I.: 0.74-0.82) and ward agreement was 0.91 (95%C.I.: 0.89-0.93). In the diabetic population, it was 0.87 (95%C.I.: 0.85-0.90). When paracetamol was used, the difference was 0.02 mmol/l (95%C.I.: 0.29-0.33).

Conclusions: Dexcom G6® provides good blood glucose level accuracy in the postoperative context of cardiac surgery compared to the standard methods of measurements. The results are particularly reliable in the ward where the need for repeated capillary glucose measurements implies patient discomfort and time-consuming manipulations for the nursing staff.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
78
期刊介绍: The Asian Cardiovascular and Thoracic Annals is an international peer-reviewed journal pertaining to cardiovascular and thoracic medicine. Besides original clinical manuscripts, we welcome research reports, product reviews, reports of new techniques, and findings of special significance to Asia and the Pacific Rim. Case studies that have significant novel original observations, are instructive, include adequate methodological details and provide conclusions. Workshop proceedings, meetings and book reviews, letters to the editor, and meeting announcements are encouraged along with relevant articles from authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信