Riccardo Bertolo , Juan Garisto , Marco Carilli , Michele Di Dio , Matteo Vittori
{"title":"应用 Veriset™ 补丁的机器人辅助无缝合技术肾部分切除术","authors":"Riccardo Bertolo , Juan Garisto , Marco Carilli , Michele Di Dio , Matteo Vittori","doi":"10.1016/j.urolvj.2024.100275","DOIUrl":null,"url":null,"abstract":"<div><p>This was the case of a 60-year-old woman diagnosed with a 6-cm cT1b renal mass (RENAL score 8). The patient was counseled for transperitoneal RPN. Anatomical tumor resection was conducted off-clamp. After the renal mass was excised, some venous bleeding foci were evident from the resection bed. By monopolar coagulation, these were managed, reducing active bleeding. Given the wide and flat surface area of the resection bed, a Veriset™ (Medtronic, Minneapolis, MN, USA) patch was introduced. We secured it to the resection bed using irrigation. Within less than a minute, hemostasis was achieved. We opted to avoid renorrhaphy.</p></div>","PeriodicalId":92972,"journal":{"name":"Urology video journal","volume":"21 ","pages":"Article 100275"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S259008972400015X/pdfft?md5=4304ff110f6753e0b31f808c5c7736a5&pid=1-s2.0-S259008972400015X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Robot-assisted partial nephrectomy with Sutureless technique by application of the Veriset™ patch\",\"authors\":\"Riccardo Bertolo , Juan Garisto , Marco Carilli , Michele Di Dio , Matteo Vittori\",\"doi\":\"10.1016/j.urolvj.2024.100275\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This was the case of a 60-year-old woman diagnosed with a 6-cm cT1b renal mass (RENAL score 8). The patient was counseled for transperitoneal RPN. Anatomical tumor resection was conducted off-clamp. After the renal mass was excised, some venous bleeding foci were evident from the resection bed. By monopolar coagulation, these were managed, reducing active bleeding. Given the wide and flat surface area of the resection bed, a Veriset™ (Medtronic, Minneapolis, MN, USA) patch was introduced. We secured it to the resection bed using irrigation. Within less than a minute, hemostasis was achieved. We opted to avoid renorrhaphy.</p></div>\",\"PeriodicalId\":92972,\"journal\":{\"name\":\"Urology video journal\",\"volume\":\"21 \",\"pages\":\"Article 100275\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S259008972400015X/pdfft?md5=4304ff110f6753e0b31f808c5c7736a5&pid=1-s2.0-S259008972400015X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urology video journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S259008972400015X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology video journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S259008972400015X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Robot-assisted partial nephrectomy with Sutureless technique by application of the Veriset™ patch
This was the case of a 60-year-old woman diagnosed with a 6-cm cT1b renal mass (RENAL score 8). The patient was counseled for transperitoneal RPN. Anatomical tumor resection was conducted off-clamp. After the renal mass was excised, some venous bleeding foci were evident from the resection bed. By monopolar coagulation, these were managed, reducing active bleeding. Given the wide and flat surface area of the resection bed, a Veriset™ (Medtronic, Minneapolis, MN, USA) patch was introduced. We secured it to the resection bed using irrigation. Within less than a minute, hemostasis was achieved. We opted to avoid renorrhaphy.