电动汽车对基于可再生能源的微电网的影响和整合:用优化的 FO-Fuzzy PSS 方法改善频率曲线

Prakash Chandra Sahu
{"title":"电动汽车对基于可再生能源的微电网的影响和整合:用优化的 FO-Fuzzy PSS 方法改善频率曲线","authors":"Prakash Chandra Sahu","doi":"10.1016/j.geits.2024.100191","DOIUrl":null,"url":null,"abstract":"<div><div>The modelling of an electric vehicle along with its integration and impact over a renewable energy based microgrid topology is well addressed in this manuscript. The frequent charging and discharging of the electric vehicle makes an oscillation over grid frequency. The performance especially frequency of an islanded AC microgrid is also affected seriously under the actions of different uncertainties like load dynamics, wind fluctuation in wind plant, solar intensity variation of PV plant etc. In order to maintain standard frequency, this research work aims to regulate the net power generation of the system in response to total demand. To monitor net generation, this work has intended a Fractional order fuzzy power system stabilizer (FO-Fuzzy PSS) control scheme in several dynamic situations. The proposed FO-Fuzzy PSS control scheme acts as most potential candidate to pertain stability in system frequency in above discussed disturbances. The controller gains are tuned optimally with suggesting an advanced-Sine Cosine Algorithm (a-SCA) under different conditions. The performance of the optimal FO-Fuzzy PSS controller is compared over standard fuzzy controller and PID controller in regard to frequency regulation of microgrid system. It is observed that proposed FO-Fuzzy PSS control scheme has the credential to reduce settling time of Δ<em>F</em><sub>1</sub> (area1 microgrid frequency) by 98.60% and 250.82% over fuzzy controller &amp; PID controller correspondingly. Further, the dynamic optimal performance of the proposed a-SCA is compared over original SCA and PSO techniques to justify its superiority.</div></div>","PeriodicalId":100596,"journal":{"name":"Green Energy and Intelligent Transportation","volume":"4 2","pages":"Article 100191"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact and integration of electric vehicles on renewable energy based microgrid: Frequency profile improvement by a-SCA optimized FO-Fuzzy PSS approach\",\"authors\":\"Prakash Chandra Sahu\",\"doi\":\"10.1016/j.geits.2024.100191\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The modelling of an electric vehicle along with its integration and impact over a renewable energy based microgrid topology is well addressed in this manuscript. The frequent charging and discharging of the electric vehicle makes an oscillation over grid frequency. The performance especially frequency of an islanded AC microgrid is also affected seriously under the actions of different uncertainties like load dynamics, wind fluctuation in wind plant, solar intensity variation of PV plant etc. In order to maintain standard frequency, this research work aims to regulate the net power generation of the system in response to total demand. To monitor net generation, this work has intended a Fractional order fuzzy power system stabilizer (FO-Fuzzy PSS) control scheme in several dynamic situations. The proposed FO-Fuzzy PSS control scheme acts as most potential candidate to pertain stability in system frequency in above discussed disturbances. The controller gains are tuned optimally with suggesting an advanced-Sine Cosine Algorithm (a-SCA) under different conditions. The performance of the optimal FO-Fuzzy PSS controller is compared over standard fuzzy controller and PID controller in regard to frequency regulation of microgrid system. It is observed that proposed FO-Fuzzy PSS control scheme has the credential to reduce settling time of Δ<em>F</em><sub>1</sub> (area1 microgrid frequency) by 98.60% and 250.82% over fuzzy controller &amp; PID controller correspondingly. Further, the dynamic optimal performance of the proposed a-SCA is compared over original SCA and PSO techniques to justify its superiority.</div></div>\",\"PeriodicalId\":100596,\"journal\":{\"name\":\"Green Energy and Intelligent Transportation\",\"volume\":\"4 2\",\"pages\":\"Article 100191\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Green Energy and Intelligent Transportation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2773153724000434\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Green Energy and Intelligent Transportation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773153724000434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。

Impact and integration of electric vehicles on renewable energy based microgrid: Frequency profile improvement by a-SCA optimized FO-Fuzzy PSS approach

Impact and integration of electric vehicles on renewable energy based microgrid: Frequency profile improvement by a-SCA optimized FO-Fuzzy PSS approach
The modelling of an electric vehicle along with its integration and impact over a renewable energy based microgrid topology is well addressed in this manuscript. The frequent charging and discharging of the electric vehicle makes an oscillation over grid frequency. The performance especially frequency of an islanded AC microgrid is also affected seriously under the actions of different uncertainties like load dynamics, wind fluctuation in wind plant, solar intensity variation of PV plant etc. In order to maintain standard frequency, this research work aims to regulate the net power generation of the system in response to total demand. To monitor net generation, this work has intended a Fractional order fuzzy power system stabilizer (FO-Fuzzy PSS) control scheme in several dynamic situations. The proposed FO-Fuzzy PSS control scheme acts as most potential candidate to pertain stability in system frequency in above discussed disturbances. The controller gains are tuned optimally with suggesting an advanced-Sine Cosine Algorithm (a-SCA) under different conditions. The performance of the optimal FO-Fuzzy PSS controller is compared over standard fuzzy controller and PID controller in regard to frequency regulation of microgrid system. It is observed that proposed FO-Fuzzy PSS control scheme has the credential to reduce settling time of ΔF1 (area1 microgrid frequency) by 98.60% and 250.82% over fuzzy controller & PID controller correspondingly. Further, the dynamic optimal performance of the proposed a-SCA is compared over original SCA and PSO techniques to justify its superiority.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信