二氧化碳聚光太阳能发电厂冷却风机性能预测调查

IF 1.2 4区 工程技术 Q3 ENGINEERING, MECHANICAL
Francois D Boshoff, Sybrand J van der Spuy, Johannes P Pretorius, Christiaan J Meyer
{"title":"二氧化碳聚光太阳能发电厂冷却风机性能预测调查","authors":"Francois D Boshoff, Sybrand J van der Spuy, Johannes P Pretorius, Christiaan J Meyer","doi":"10.1177/09576509241237840","DOIUrl":null,"url":null,"abstract":"An axial flow fan is designed for dry cooling of a sCO<jats:sub>2</jats:sub> Brayton cycle for a CSP plant, and a scaled model of the fan is manufactured and tested experimentally in an ISO 5801:2017 Type A fan test facility. While the design procedure’s estimate of the total-to-static efficiency at the design flow rate is relatively high, at 74.4%, the experimental fan efficiency was found to be only 50.6%. This paper details an investigation into the causes of fan performance degradation, using both experimental and numerical methods. The investigation finds that the hub configuration, tip clearance size, and scale of the test fan is responsible for the reduced performance. Two alternative hub and casing configurations are identified which improve the fan’s performance significantly.","PeriodicalId":20705,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation into the predicted performance of a cooling fan for an sCO2 concentrated solar power plant\",\"authors\":\"Francois D Boshoff, Sybrand J van der Spuy, Johannes P Pretorius, Christiaan J Meyer\",\"doi\":\"10.1177/09576509241237840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An axial flow fan is designed for dry cooling of a sCO<jats:sub>2</jats:sub> Brayton cycle for a CSP plant, and a scaled model of the fan is manufactured and tested experimentally in an ISO 5801:2017 Type A fan test facility. While the design procedure’s estimate of the total-to-static efficiency at the design flow rate is relatively high, at 74.4%, the experimental fan efficiency was found to be only 50.6%. This paper details an investigation into the causes of fan performance degradation, using both experimental and numerical methods. The investigation finds that the hub configuration, tip clearance size, and scale of the test fan is responsible for the reduced performance. Two alternative hub and casing configurations are identified which improve the fan’s performance significantly.\",\"PeriodicalId\":20705,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09576509241237840\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09576509241237840","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

设计了一种轴流式风机,用于 CSP 电站 sCO2 布莱顿循环的干式冷却,并在 ISO 5801:2017 A 型风机测试设备中制造和实验测试了该风机的比例模型。虽然设计程序对设计流速下总静态效率的估算相对较高,达到 74.4%,但实验发现风机效率仅为 50.6%。本文采用实验和数值方法详细调查了风扇性能下降的原因。调查发现,测试风扇的轮毂配置、叶尖间隙大小和规模是性能下降的原因。本文确定了两种可供选择的轮毂和外壳配置,可显著提高风扇的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation into the predicted performance of a cooling fan for an sCO2 concentrated solar power plant
An axial flow fan is designed for dry cooling of a sCO2 Brayton cycle for a CSP plant, and a scaled model of the fan is manufactured and tested experimentally in an ISO 5801:2017 Type A fan test facility. While the design procedure’s estimate of the total-to-static efficiency at the design flow rate is relatively high, at 74.4%, the experimental fan efficiency was found to be only 50.6%. This paper details an investigation into the causes of fan performance degradation, using both experimental and numerical methods. The investigation finds that the hub configuration, tip clearance size, and scale of the test fan is responsible for the reduced performance. Two alternative hub and casing configurations are identified which improve the fan’s performance significantly.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.30
自引率
5.90%
发文量
114
审稿时长
5.4 months
期刊介绍: The Journal of Power and Energy, Part A of the Proceedings of the Institution of Mechanical Engineers, is dedicated to publishing peer-reviewed papers of high scientific quality on all aspects of the technology of energy conversion systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信