{"title":"用于恙虫病血清学诊断的免疫层析试验。","authors":"Shuhao Yan ,&nbsp;Qingyu Lu ,&nbsp;Qingyuan Tao ,&nbsp;Yawei Lu ,&nbsp;Bao Gao ,&nbsp;Sibo Wang ,&nbsp;Xusheng Cai ,&nbsp;Lele Ai ,&nbsp;Xiaohui Xiong ,&nbsp;Min Cao ,&nbsp;Weilong Tan","doi":"10.1016/j.jim.2024.113653","DOIUrl":null,"url":null,"abstract":"<div><p>A fluorescent immunochromatographic test (FM-ICT) was developed for rapid detection of anti-<em>Orientia tsutsugamushi</em> antibodies in serum samples. The FM-ICT was constructed based on the dual-antigen sandwich method. Truncated 56 kDa outer membrane protein of <em>O. tsutsugamushi</em> strain SJ, was expressed in <em>E. coli</em> and mixed with those of Ptan and Gillam strains. A thin line of the protein mixture was precisely sprayed across a nitrocellulose membrane making this the “Test” line. Polyclonal antibodies (pAbs) to <em>O.tsutsugamushi</em> were sprayed in another line across the membrane making this the “Control” line. Fluorescent microspheres conjugated 56 kDa proteins reacting with sample serum will be captured on the “Test” line if the sample contains antibodies to <em>O.tsutsugamushi</em>. Several experimental parameters were optimized. After optimizing the reaction procedure, the results are visible, within 6 min, with the naked eye under ultraviolet light. The limit of detection (LOD) was determined to be 7.63 ng/mL with prepared polyclonal antibodies. No cross-reaction was observed with sera samples from other febrile diseases. In clinical evaluations, the strips showed 94.92% sensitivity (106/112) and 93.75% specificity (56/60). The FM-ICT we developed will provide a new tool for on-site diagnosis of scrub typhus<em>.</em></p></div>","PeriodicalId":16000,"journal":{"name":"Journal of immunological methods","volume":"528 ","pages":"Article 113653"},"PeriodicalIF":1.6000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An immunochromatographic test for serological diagnosis of scrub typhus\",\"authors\":\"Shuhao Yan ,&nbsp;Qingyu Lu ,&nbsp;Qingyuan Tao ,&nbsp;Yawei Lu ,&nbsp;Bao Gao ,&nbsp;Sibo Wang ,&nbsp;Xusheng Cai ,&nbsp;Lele Ai ,&nbsp;Xiaohui Xiong ,&nbsp;Min Cao ,&nbsp;Weilong Tan\",\"doi\":\"10.1016/j.jim.2024.113653\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A fluorescent immunochromatographic test (FM-ICT) was developed for rapid detection of anti-<em>Orientia tsutsugamushi</em> antibodies in serum samples. The FM-ICT was constructed based on the dual-antigen sandwich method. Truncated 56 kDa outer membrane protein of <em>O. tsutsugamushi</em> strain SJ, was expressed in <em>E. coli</em> and mixed with those of Ptan and Gillam strains. A thin line of the protein mixture was precisely sprayed across a nitrocellulose membrane making this the “Test” line. Polyclonal antibodies (pAbs) to <em>O.tsutsugamushi</em> were sprayed in another line across the membrane making this the “Control” line. Fluorescent microspheres conjugated 56 kDa proteins reacting with sample serum will be captured on the “Test” line if the sample contains antibodies to <em>O.tsutsugamushi</em>. Several experimental parameters were optimized. After optimizing the reaction procedure, the results are visible, within 6 min, with the naked eye under ultraviolet light. The limit of detection (LOD) was determined to be 7.63 ng/mL with prepared polyclonal antibodies. No cross-reaction was observed with sera samples from other febrile diseases. In clinical evaluations, the strips showed 94.92% sensitivity (106/112) and 93.75% specificity (56/60). The FM-ICT we developed will provide a new tool for on-site diagnosis of scrub typhus<em>.</em></p></div>\",\"PeriodicalId\":16000,\"journal\":{\"name\":\"Journal of immunological methods\",\"volume\":\"528 \",\"pages\":\"Article 113653\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of immunological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022175924000383\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022175924000383","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

开发了一种荧光免疫层析检测法(FM-ICT),用于快速检测血清样本中的抗恙虫病抗体。FM-ICT 是基于双抗原夹心法构建的。在大肠杆菌中表达恙虫病 SJ 株的截短的 56 kDa 外膜蛋白,并将其与 Ptan 株和 Gillam 株的外膜蛋白混合。在硝酸纤维素膜上精确地喷洒一细线的蛋白质混合物,使其成为 "测试 "线。恙虫多克隆抗体(pAbs)被喷洒在膜上的另一条线上,这就是 "对照 "线。如果样品中含有恙虫卵抗体,与样品血清反应的 56 kDa 蛋白质连接的荧光微球将被捕获到 "测试 "线上。对几个实验参数进行了优化。优化反应程序后,6 分钟内肉眼在紫外光下即可看到结果。使用制备的多克隆抗体,检测限(LOD)被确定为 7.63 纳克/毫升。与其他发热疾病的血清样本未发现交叉反应。在临床评估中,试纸条的灵敏度为 94.92%(106/112),特异度为 93.75%(56/60)。我们开发的 FM-ICT 将为现场诊断恙虫病提供一种新工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An immunochromatographic test for serological diagnosis of scrub typhus

A fluorescent immunochromatographic test (FM-ICT) was developed for rapid detection of anti-Orientia tsutsugamushi antibodies in serum samples. The FM-ICT was constructed based on the dual-antigen sandwich method. Truncated 56 kDa outer membrane protein of O. tsutsugamushi strain SJ, was expressed in E. coli and mixed with those of Ptan and Gillam strains. A thin line of the protein mixture was precisely sprayed across a nitrocellulose membrane making this the “Test” line. Polyclonal antibodies (pAbs) to O.tsutsugamushi were sprayed in another line across the membrane making this the “Control” line. Fluorescent microspheres conjugated 56 kDa proteins reacting with sample serum will be captured on the “Test” line if the sample contains antibodies to O.tsutsugamushi. Several experimental parameters were optimized. After optimizing the reaction procedure, the results are visible, within 6 min, with the naked eye under ultraviolet light. The limit of detection (LOD) was determined to be 7.63 ng/mL with prepared polyclonal antibodies. No cross-reaction was observed with sera samples from other febrile diseases. In clinical evaluations, the strips showed 94.92% sensitivity (106/112) and 93.75% specificity (56/60). The FM-ICT we developed will provide a new tool for on-site diagnosis of scrub typhus.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
120
审稿时长
3 months
期刊介绍: The Journal of Immunological Methods is devoted to covering techniques for: (1) Quantitating and detecting antibodies and/or antigens. (2) Purifying immunoglobulins, lymphokines and other molecules of the immune system. (3) Isolating antigens and other substances important in immunological processes. (4) Labelling antigens and antibodies. (5) Localizing antigens and/or antibodies in tissues and cells. (6) Detecting, and fractionating immunocompetent cells. (7) Assaying for cellular immunity. (8) Documenting cell-cell interactions. (9) Initiating immunity and unresponsiveness. (10) Transplanting tissues. (11) Studying items closely related to immunity such as complement, reticuloendothelial system and others. (12) Molecular techniques for studying immune cells and their receptors. (13) Imaging of the immune system. (14) Methods for production or their fragments in eukaryotic and prokaryotic cells. In addition the journal will publish articles on novel methods for analysing the organization, structure and expression of genes for immunologically important molecules such as immunoglobulins, T cell receptors and accessory molecules involved in antigen recognition, processing and presentation. Submitted full length manuscripts should describe new methods of broad applicability to immunology and not simply the application of an established method to a particular substance - although papers describing such applications may be considered for publication as a short Technical Note. Review articles will also be published by the Journal of Immunological Methods. In general these manuscripts are by solicitation however anyone interested in submitting a review can contact the Reviews Editor and provide an outline of the proposed review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信