Ana Luiza E Carneiro, Isabella N R Reis, Fernando Valentim Bitencourt, Daniela M R A Salgado, Claudio Costa, Rubens Spin-Neto
{"title":"基于低剂量锥形束 CT 方案的种植规划线性测量的准确性:系统综述和荟萃分析低剂量 CBCT 的准确性:系统综述和荟萃分析。","authors":"Ana Luiza E Carneiro, Isabella N R Reis, Fernando Valentim Bitencourt, Daniela M R A Salgado, Claudio Costa, Rubens Spin-Neto","doi":"10.1093/dmfr/twae007","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols.</p><p><strong>Methods: </strong>The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data.</p><p><strong>Results: </strong>The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible.</p><p><strong>Conclusion: </strong>Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":"207-221"},"PeriodicalIF":2.9000,"publicationDate":"2024-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11056743/pdf/","citationCount":"0","resultStr":"{\"title\":\"Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis.\",\"authors\":\"Ana Luiza E Carneiro, Isabella N R Reis, Fernando Valentim Bitencourt, Daniela M R A Salgado, Claudio Costa, Rubens Spin-Neto\",\"doi\":\"10.1093/dmfr/twae007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols.</p><p><strong>Methods: </strong>The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data.</p><p><strong>Results: </strong>The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible.</p><p><strong>Conclusion: </strong>Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.</p>\",\"PeriodicalId\":11261,\"journal\":{\"name\":\"Dento maxillo facial radiology\",\"volume\":\" \",\"pages\":\"207-221\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11056743/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dento maxillo facial radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/dmfr/twae007\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twae007","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis.
Objectives: The aim of this systematic review was to verify the accuracy of linear measurements performed on low-dose CBCT protocols for implant planning, in comparison with those performed on standard and high-resolution CBCT protocols.
Methods: The literature search included four databases (Pubmed, Web of Science, Embase, and Scopus). Two reviewers independently screened titles/abstracts and full texts according to eligibility criteria, extracted the data, and examined the methodological quality. Risk of bias assessment was performed using the Quality Assessment Tool For In Vitro Studies. Random-effects meta-analysis was used for pooling measurement error data.
Results: The initial search yielded 4684 titles. In total, 13 studies were included in the systematic review, representing a total of 81 samples, while 9 studies were included in the meta-analysis. The risk of bias ranged from medium to low. The main results across the studies indicate a strong consistency in linear measurements performed on low-dose images in relation to the reference methods. The overall pooled planning measurement error from low-dose CBCT protocols was -0.24 mm (95% CI, -0.52 to 0.04) with a high level of heterogeneity, showing a tendency for underestimation of real values. Various studies found no significant differences in measurements across different protocols (eg, voxel sizes, mA settings, or dose levels), regions (incisor, premolar, molar) and types (height vs. width). Some studies, however, noted exceptions in measurements performed on the posterior mandible.
Conclusion: Low-dose CBCT protocols offer adequate precision and accuracy of linear measurements for implant planning. Nevertheless, diagnostic image quality needs must be taken into consideration when choosing a low-dose CBCT protocol.
期刊介绍:
Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging.
Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology.
The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal.
Quick Facts:
- 2015 Impact Factor - 1.919
- Receipt to first decision - average of 3 weeks
- Acceptance to online publication - average of 3 weeks
- Open access option
- ISSN: 0250-832X
- eISSN: 1476-542X