Leah M Savitsky, Caitlin Hamilton, Mary Sterrett, Kelsey Olerich, Kimberly Ma, Catherine M Albright
{"title":"针对妊娠糖尿病的通用胎儿超声心动图检查:成本效益分析","authors":"Leah M Savitsky, Caitlin Hamilton, Mary Sterrett, Kelsey Olerich, Kimberly Ma, Catherine M Albright","doi":"10.1097/AOG.0000000000005538","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the cost effectiveness of universal fetal echocardiogram for patients with pregestational diabetes mellitus by first-trimester hemoglobin A 1c (Hb A 1c ) level.</p><p><strong>Methods: </strong>We developed a cost-effectiveness model comparing two strategies of screening for critical fetal congenital heart disease among patients with diabetes: universal fetal echocardiogram and fetal echocardiogram only after abnormal findings on detailed anatomy ultrasonogram. We excluded ventricular septal defect, atrial septal defects, and bicuspid aortic valve from the definition of critical fetal congenital heart disease. Probabilities and costs were derived from the literature. We used individual models to evaluate different scenarios: first-trimester Hb A 1c lower than 6.5%, Hb A 1c 6.5-9.0%, and Hb A 1c higher than 9.0%. Primary outcomes included fetal death, neonatal death, and false-positive and false-negative results. A cost-effectiveness threshold was set at $100,000 per quality-adjusted life-year. Univariable sensitivity analyses were performed to investigate the drivers of the model.</p><p><strong>Results: </strong>Universal fetal echocardiogram is not cost effective except for when first-trimester Hb A 1c level is higher than 9.0% (incremental cost-effectiveness ratio $638,100, $223,693, and $67,697 for Hb A 1c lower than 6.5%, 6.5-9.0%, and higher than 9.0%, respectively). The models are sensitive to changes in the probability of congenital heart disease at a given Hb A 1c level, as well as the cost of neonatal transfer to a higher level of care. Universal fetal echocardiogram became both cost saving and more effective when the probability of congenital heart disease reached 14.48% (15.4 times the baseline risk). In the Monte Carlo simulation, universal fetal echocardiogram is cost effective in 22.7%, 48.6%, and 62.3% of scenarios for each of the three models, respectively.</p><p><strong>Conclusion: </strong>For pregnant patients with first-trimester Hb A 1c levels lower than 6.5%, universal fetal echocardiogram was not cost effective, whereas, for those with first-trimester Hb A 1c levels higher than 9.0%, universal fetal echocardiogram was cost effective. For those with intermediate Hb A 1c levels, universal fetal echocardiogram was cost effective in about 50% of cases; therefore, clinical judgment based on individual patient values, willingness to pay to detect congenital heart disease, and resource availability needs to be considered.</p>","PeriodicalId":5,"journal":{"name":"ACS Applied Materials & Interfaces","volume":null,"pages":null},"PeriodicalIF":8.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Universal Fetal Echocardiography for Pregestational Diabetes Mellitus: A Cost-Effectiveness Analysis.\",\"authors\":\"Leah M Savitsky, Caitlin Hamilton, Mary Sterrett, Kelsey Olerich, Kimberly Ma, Catherine M Albright\",\"doi\":\"10.1097/AOG.0000000000005538\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the cost effectiveness of universal fetal echocardiogram for patients with pregestational diabetes mellitus by first-trimester hemoglobin A 1c (Hb A 1c ) level.</p><p><strong>Methods: </strong>We developed a cost-effectiveness model comparing two strategies of screening for critical fetal congenital heart disease among patients with diabetes: universal fetal echocardiogram and fetal echocardiogram only after abnormal findings on detailed anatomy ultrasonogram. We excluded ventricular septal defect, atrial septal defects, and bicuspid aortic valve from the definition of critical fetal congenital heart disease. Probabilities and costs were derived from the literature. We used individual models to evaluate different scenarios: first-trimester Hb A 1c lower than 6.5%, Hb A 1c 6.5-9.0%, and Hb A 1c higher than 9.0%. Primary outcomes included fetal death, neonatal death, and false-positive and false-negative results. A cost-effectiveness threshold was set at $100,000 per quality-adjusted life-year. Univariable sensitivity analyses were performed to investigate the drivers of the model.</p><p><strong>Results: </strong>Universal fetal echocardiogram is not cost effective except for when first-trimester Hb A 1c level is higher than 9.0% (incremental cost-effectiveness ratio $638,100, $223,693, and $67,697 for Hb A 1c lower than 6.5%, 6.5-9.0%, and higher than 9.0%, respectively). The models are sensitive to changes in the probability of congenital heart disease at a given Hb A 1c level, as well as the cost of neonatal transfer to a higher level of care. Universal fetal echocardiogram became both cost saving and more effective when the probability of congenital heart disease reached 14.48% (15.4 times the baseline risk). In the Monte Carlo simulation, universal fetal echocardiogram is cost effective in 22.7%, 48.6%, and 62.3% of scenarios for each of the three models, respectively.</p><p><strong>Conclusion: </strong>For pregnant patients with first-trimester Hb A 1c levels lower than 6.5%, universal fetal echocardiogram was not cost effective, whereas, for those with first-trimester Hb A 1c levels higher than 9.0%, universal fetal echocardiogram was cost effective. For those with intermediate Hb A 1c levels, universal fetal echocardiogram was cost effective in about 50% of cases; therefore, clinical judgment based on individual patient values, willingness to pay to detect congenital heart disease, and resource availability needs to be considered.</p>\",\"PeriodicalId\":5,\"journal\":{\"name\":\"ACS Applied Materials & Interfaces\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.3000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Materials & Interfaces\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/AOG.0000000000005538\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Materials & Interfaces","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AOG.0000000000005538","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
Universal Fetal Echocardiography for Pregestational Diabetes Mellitus: A Cost-Effectiveness Analysis.
Objective: To evaluate the cost effectiveness of universal fetal echocardiogram for patients with pregestational diabetes mellitus by first-trimester hemoglobin A 1c (Hb A 1c ) level.
Methods: We developed a cost-effectiveness model comparing two strategies of screening for critical fetal congenital heart disease among patients with diabetes: universal fetal echocardiogram and fetal echocardiogram only after abnormal findings on detailed anatomy ultrasonogram. We excluded ventricular septal defect, atrial septal defects, and bicuspid aortic valve from the definition of critical fetal congenital heart disease. Probabilities and costs were derived from the literature. We used individual models to evaluate different scenarios: first-trimester Hb A 1c lower than 6.5%, Hb A 1c 6.5-9.0%, and Hb A 1c higher than 9.0%. Primary outcomes included fetal death, neonatal death, and false-positive and false-negative results. A cost-effectiveness threshold was set at $100,000 per quality-adjusted life-year. Univariable sensitivity analyses were performed to investigate the drivers of the model.
Results: Universal fetal echocardiogram is not cost effective except for when first-trimester Hb A 1c level is higher than 9.0% (incremental cost-effectiveness ratio $638,100, $223,693, and $67,697 for Hb A 1c lower than 6.5%, 6.5-9.0%, and higher than 9.0%, respectively). The models are sensitive to changes in the probability of congenital heart disease at a given Hb A 1c level, as well as the cost of neonatal transfer to a higher level of care. Universal fetal echocardiogram became both cost saving and more effective when the probability of congenital heart disease reached 14.48% (15.4 times the baseline risk). In the Monte Carlo simulation, universal fetal echocardiogram is cost effective in 22.7%, 48.6%, and 62.3% of scenarios for each of the three models, respectively.
Conclusion: For pregnant patients with first-trimester Hb A 1c levels lower than 6.5%, universal fetal echocardiogram was not cost effective, whereas, for those with first-trimester Hb A 1c levels higher than 9.0%, universal fetal echocardiogram was cost effective. For those with intermediate Hb A 1c levels, universal fetal echocardiogram was cost effective in about 50% of cases; therefore, clinical judgment based on individual patient values, willingness to pay to detect congenital heart disease, and resource availability needs to be considered.
期刊介绍:
ACS Applied Materials & Interfaces is a leading interdisciplinary journal that brings together chemists, engineers, physicists, and biologists to explore the development and utilization of newly-discovered materials and interfacial processes for specific applications. Our journal has experienced remarkable growth since its establishment in 2009, both in terms of the number of articles published and the impact of the research showcased. We are proud to foster a truly global community, with the majority of published articles originating from outside the United States, reflecting the rapid growth of applied research worldwide.