"一种方法标记所有":符合 GMP 标准的 PSMA-11 68Ga 放射性标记全自动单一方案,可转用 PSMA-I&T 和 PSMA-617。

IF 1.5 4区 医学 Q3 PHARMACOLOGY & PHARMACY
Juliette Fouillet, Charlotte Donzé, Emmanuel Deshayes, Lore Santoro, Léa Rubira, Cyril Fersing
{"title":"\"一种方法标记所有\":符合 GMP 标准的 PSMA-11 68Ga 放射性标记全自动单一方案,可转用 PSMA-I&T 和 PSMA-617。","authors":"Juliette Fouillet, Charlotte Donzé, Emmanuel Deshayes, Lore Santoro, Léa Rubira, Cyril Fersing","doi":"10.2174/0118744710293461240219111852","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prostate-specific membrane antigen (PSMA) is an ideal target for molecular imaging and targeted radionuclide therapy in prostate cancer. Consequently, various PSMA ligands were developed. Some of these molecules are functionalized with a chelator that can host radiometals, such as <sup>68</sup>Ga for PET imaging. The <sup>68</sup>Ga radiolabeling step benefits from process automation, making it more robust and reducing radiation exposure.</p><p><strong>Objective: </strong>To design a single automated radiolabeling protocol for the GMP-compliant preparation of [<sup>68</sup>Ga]Ga-PSMA-11, transposable to the production of [<sup>68</sup>Ga]Ga-PSMA-617 and [<sup>68</sup>Ga]Ga-PSMA-I&T.</p><p><strong>Methods: </strong>A GAIA<sup>®</sup> synthesis module and a GALLIAD<sup>®</sup> generator were used. Radio-TLC and radio-HPLC methods were validated for radiochemical purity (RCP) determination. Three [<sup>68</sup>Ga]Ga-PSMA-11 validation batches were produced and thoroughly tested for appearance and pH, radionuclide identity and purity, RCP, stability, residual solvent and sterility. Minimal modifications were made to the reagents and disposables for optimal application to other PSMA ligands.</p><p><strong>Results: </strong>[<sup>68</sup>Ga]Ga-PSMA-11 for clinical application was produced in 27 min. The 3 validation batches met the quality criteria expected by the European Pharmacopoeia to allow routine production. For optimal transposition to PSMA-617, the solid phase extraction cartridge was changed to improve purification of the radiolabeled product. For application to PSMA-I&T, the buffer solution initially used was replaced by HEPES 2.7 M to achieve good radiochemical yields. Residual HEPES content was checked in the final product and was below the Ph. Eur. threshold.</p><p><strong>Conclusion: </strong>A single automated radiolabeling method on the GAIA<sup>®</sup> module was developed and implemented for <sup>68</sup>Ga radiolabeling of 3 PSMA ligands, with slight adjustments for each molecule.</p>","PeriodicalId":10991,"journal":{"name":"Current radiopharmaceuticals","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11348474/pdf/","citationCount":"0","resultStr":"{\"title\":\"\\\"One Method to Label Them All\\\": A Single Fully Automated Protocol for GMP-Compliant <sup>68</sup>Ga Radiolabeling of PSMA-11, Transposable to PSMA-I&T and PSMA-617.\",\"authors\":\"Juliette Fouillet, Charlotte Donzé, Emmanuel Deshayes, Lore Santoro, Léa Rubira, Cyril Fersing\",\"doi\":\"10.2174/0118744710293461240219111852\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Prostate-specific membrane antigen (PSMA) is an ideal target for molecular imaging and targeted radionuclide therapy in prostate cancer. Consequently, various PSMA ligands were developed. Some of these molecules are functionalized with a chelator that can host radiometals, such as <sup>68</sup>Ga for PET imaging. The <sup>68</sup>Ga radiolabeling step benefits from process automation, making it more robust and reducing radiation exposure.</p><p><strong>Objective: </strong>To design a single automated radiolabeling protocol for the GMP-compliant preparation of [<sup>68</sup>Ga]Ga-PSMA-11, transposable to the production of [<sup>68</sup>Ga]Ga-PSMA-617 and [<sup>68</sup>Ga]Ga-PSMA-I&T.</p><p><strong>Methods: </strong>A GAIA<sup>®</sup> synthesis module and a GALLIAD<sup>®</sup> generator were used. Radio-TLC and radio-HPLC methods were validated for radiochemical purity (RCP) determination. Three [<sup>68</sup>Ga]Ga-PSMA-11 validation batches were produced and thoroughly tested for appearance and pH, radionuclide identity and purity, RCP, stability, residual solvent and sterility. Minimal modifications were made to the reagents and disposables for optimal application to other PSMA ligands.</p><p><strong>Results: </strong>[<sup>68</sup>Ga]Ga-PSMA-11 for clinical application was produced in 27 min. The 3 validation batches met the quality criteria expected by the European Pharmacopoeia to allow routine production. For optimal transposition to PSMA-617, the solid phase extraction cartridge was changed to improve purification of the radiolabeled product. For application to PSMA-I&T, the buffer solution initially used was replaced by HEPES 2.7 M to achieve good radiochemical yields. Residual HEPES content was checked in the final product and was below the Ph. Eur. threshold.</p><p><strong>Conclusion: </strong>A single automated radiolabeling method on the GAIA<sup>®</sup> module was developed and implemented for <sup>68</sup>Ga radiolabeling of 3 PSMA ligands, with slight adjustments for each molecule.</p>\",\"PeriodicalId\":10991,\"journal\":{\"name\":\"Current radiopharmaceuticals\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11348474/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current radiopharmaceuticals\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2174/0118744710293461240219111852\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current radiopharmaceuticals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/0118744710293461240219111852","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

背景:前列腺特异性膜抗原(PSMA前列腺特异性膜抗原(PSMA)是前列腺癌分子成像和放射性核素靶向治疗的理想靶点。因此,各种 PSMA 配体应运而生。其中一些分子被螯合剂功能化,可以承载放射性金属,如用于 PET 成像的 68Ga。68Ga 放射性标记步骤得益于流程自动化,使其更加稳健并减少辐射暴露:目的:为符合 GMP 标准的[68Ga]Ga-PSMA-11 的制备设计一个单一的自动化放射性标记方案,该方案可用于生产[68Ga]Ga-PSMA-617 和 [68Ga]Ga-PSMA-I&T:方法:使用 GAIA® 合成模块和 GALLIAD® 发生器。方法:使用 GAIA® 合成模块和 GALLIAD® 发生器,对放射化学纯度 (RCP) 的测定进行了放射性-TLC 和放射性-HPLC 方法验证。生产了三个[68Ga]Ga-PSMA-11 验证批次,并对其外观和 pH 值、放射性核素特性和纯度、RCP、稳定性、残留溶剂和无菌性进行了全面测试。为了更好地应用于其他 PSMA 配体,对试剂和一次性用品进行了最小限度的修改:结果:用于临床应用的[68Ga]Ga-PSMA-11 在 27 分钟内完成生产。3 个验证批次符合欧洲药典的预期质量标准,可以进行常规生产。为优化转用于 PSMA-617,改变了固相萃取盒以提高放射性标记产品的纯度。为了应用于 PSMA-I&T,最初使用的缓冲溶液换成了 2.7 M 的 HEPES,以获得良好的放射化学收率。对最终产品中残留的 HEPES 含量进行了检测,结果低于欧洲药典的阈值:结论:在 GAIA® 模块上开发并实施了一种单一的自动放射性标记方法,用于对 3 种 PSMA 配体进行 68Ga 放射性标记,并对每种分子稍作调整。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
"One Method to Label Them All": A Single Fully Automated Protocol for GMP-Compliant 68Ga Radiolabeling of PSMA-11, Transposable to PSMA-I&T and PSMA-617.

Background: Prostate-specific membrane antigen (PSMA) is an ideal target for molecular imaging and targeted radionuclide therapy in prostate cancer. Consequently, various PSMA ligands were developed. Some of these molecules are functionalized with a chelator that can host radiometals, such as 68Ga for PET imaging. The 68Ga radiolabeling step benefits from process automation, making it more robust and reducing radiation exposure.

Objective: To design a single automated radiolabeling protocol for the GMP-compliant preparation of [68Ga]Ga-PSMA-11, transposable to the production of [68Ga]Ga-PSMA-617 and [68Ga]Ga-PSMA-I&T.

Methods: A GAIA® synthesis module and a GALLIAD® generator were used. Radio-TLC and radio-HPLC methods were validated for radiochemical purity (RCP) determination. Three [68Ga]Ga-PSMA-11 validation batches were produced and thoroughly tested for appearance and pH, radionuclide identity and purity, RCP, stability, residual solvent and sterility. Minimal modifications were made to the reagents and disposables for optimal application to other PSMA ligands.

Results: [68Ga]Ga-PSMA-11 for clinical application was produced in 27 min. The 3 validation batches met the quality criteria expected by the European Pharmacopoeia to allow routine production. For optimal transposition to PSMA-617, the solid phase extraction cartridge was changed to improve purification of the radiolabeled product. For application to PSMA-I&T, the buffer solution initially used was replaced by HEPES 2.7 M to achieve good radiochemical yields. Residual HEPES content was checked in the final product and was below the Ph. Eur. threshold.

Conclusion: A single automated radiolabeling method on the GAIA® module was developed and implemented for 68Ga radiolabeling of 3 PSMA ligands, with slight adjustments for each molecule.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current radiopharmaceuticals
Current radiopharmaceuticals PHARMACOLOGY & PHARMACY-
CiteScore
3.20
自引率
4.30%
发文量
43
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信