Alexander Wurzer, Francesco De Rose, Sebastian Fischer, Markus Schwaiger, Wolfgang Weber, Stephan Nekolla, Hans-Jürgen Wester, Matthias Eiber, Calogero D’Alessandria
{"title":"用于前列腺癌放射治疗的[177Lu]Lu-rhPSMA-10.1和[177Lu]Lu-rhPSMA-10.2的临床前比较:生物分布和剂量学研究","authors":"Alexander Wurzer, Francesco De Rose, Sebastian Fischer, Markus Schwaiger, Wolfgang Weber, Stephan Nekolla, Hans-Jürgen Wester, Matthias Eiber, Calogero D’Alessandria","doi":"10.1186/s41181-024-00246-2","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Radiohybrid PSMA-targeted ligands (rhPSMA) have been introduced as a novel platform for theranostic applications. Among a variety of rhPSMA-ligands developed for radioligand therapy, two stereoisomers [<sup>177</sup>Lu]Lu-rhPSMA-10.1 and -10.2 have been synthesized and initially characterized in preclinical experiments with the aim to provide an optimized binding profile to human serum albumin, a reduction of charge, and thus accelerated kidney excretion, and unaffected or even improved tumor uptake. As both isomers showed similar in vitro characteristics and tumor uptake at 24 h post injection in tumor bearing mice and in order to identify the isomer with the most favorable pharmacokinetics for radioligand therapy, we carried out in-depth biodistribution and dosimetry studies in tumor-bearing and healthy mice.</p><h3>Results</h3><p>rhPSMA-10.1 and -10.2 were radiolabeled with lutetium-177 according to the established procedures of other DOTA-based PSMA ligands and displayed a high and comparable stability in all buffers and human serum (> 97%, 24 h). Biodistribution studies revealed fast clearance from the blood pool (0.3–0.6%ID/g at 1 h) and other background tissues within 48 h. Distinctive differences were found in the kidneys, where [<sup>177</sup>Lu]Lu-rhPSMA-10.1 displayed lower initial uptake and faster excretion kinetics compared to [<sup>177</sup>Lu]Lu-rhPSMA-10.2 expressed by a 1.5-fold and ninefold lower uptake value at 1 h and 24 h in healthy animals, respectively. Tumor uptake was comparable and in the range of 8.6–11.6%ID/g for both isomers over 24 h and was maintained up to 168 h at a level of 2.2 ± 0.8 and 4.1 ± 1.4%ID/g for [<sup>177</sup>Lu]Lu-rhPSMA-10.1 and [<sup>177</sup>Lu]Lu-rhPSMA-10.2, respectively.</p><h3>Conclusion</h3><p>Our preclinical data on biodistribution and dosimetry indicate a more favorable profile of [<sup>177</sup>Lu]Lu-rhPSMA-10.1 compared to [<sup>177</sup>Lu]Lu-rhPSMA-10.2 for PSMA-targeted radioligand therapy. [<sup>177</sup>Lu]Lu-rhPSMA-10.1 shows fast kidney clearance kinetics resulting in excellent tumor-to-organ ratios over a therapy relevant time course. Meanwhile, [<sup>177</sup>Lu]Lu-rhPSMA-10.1 is currently being investigated in clinical phase I/II studies in patients with mCRPC (NCT05413850), in patients with high-risk localized PC (NCT06066437, Nautilus Trial) and after external beam radiotherapy (NCT06105918).</p></div>","PeriodicalId":534,"journal":{"name":"EJNMMI Radiopharmacy and Chemistry","volume":"9 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2024-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-024-00246-2","citationCount":"0","resultStr":"{\"title\":\"Preclinical comparison of [177Lu]Lu-rhPSMA-10.1 and [177Lu]Lu-rhPSMA-10.2 for endoradiotherapy of prostate cancer: biodistribution and dosimetry studies\",\"authors\":\"Alexander Wurzer, Francesco De Rose, Sebastian Fischer, Markus Schwaiger, Wolfgang Weber, Stephan Nekolla, Hans-Jürgen Wester, Matthias Eiber, Calogero D’Alessandria\",\"doi\":\"10.1186/s41181-024-00246-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Radiohybrid PSMA-targeted ligands (rhPSMA) have been introduced as a novel platform for theranostic applications. Among a variety of rhPSMA-ligands developed for radioligand therapy, two stereoisomers [<sup>177</sup>Lu]Lu-rhPSMA-10.1 and -10.2 have been synthesized and initially characterized in preclinical experiments with the aim to provide an optimized binding profile to human serum albumin, a reduction of charge, and thus accelerated kidney excretion, and unaffected or even improved tumor uptake. As both isomers showed similar in vitro characteristics and tumor uptake at 24 h post injection in tumor bearing mice and in order to identify the isomer with the most favorable pharmacokinetics for radioligand therapy, we carried out in-depth biodistribution and dosimetry studies in tumor-bearing and healthy mice.</p><h3>Results</h3><p>rhPSMA-10.1 and -10.2 were radiolabeled with lutetium-177 according to the established procedures of other DOTA-based PSMA ligands and displayed a high and comparable stability in all buffers and human serum (> 97%, 24 h). Biodistribution studies revealed fast clearance from the blood pool (0.3–0.6%ID/g at 1 h) and other background tissues within 48 h. Distinctive differences were found in the kidneys, where [<sup>177</sup>Lu]Lu-rhPSMA-10.1 displayed lower initial uptake and faster excretion kinetics compared to [<sup>177</sup>Lu]Lu-rhPSMA-10.2 expressed by a 1.5-fold and ninefold lower uptake value at 1 h and 24 h in healthy animals, respectively. Tumor uptake was comparable and in the range of 8.6–11.6%ID/g for both isomers over 24 h and was maintained up to 168 h at a level of 2.2 ± 0.8 and 4.1 ± 1.4%ID/g for [<sup>177</sup>Lu]Lu-rhPSMA-10.1 and [<sup>177</sup>Lu]Lu-rhPSMA-10.2, respectively.</p><h3>Conclusion</h3><p>Our preclinical data on biodistribution and dosimetry indicate a more favorable profile of [<sup>177</sup>Lu]Lu-rhPSMA-10.1 compared to [<sup>177</sup>Lu]Lu-rhPSMA-10.2 for PSMA-targeted radioligand therapy. [<sup>177</sup>Lu]Lu-rhPSMA-10.1 shows fast kidney clearance kinetics resulting in excellent tumor-to-organ ratios over a therapy relevant time course. Meanwhile, [<sup>177</sup>Lu]Lu-rhPSMA-10.1 is currently being investigated in clinical phase I/II studies in patients with mCRPC (NCT05413850), in patients with high-risk localized PC (NCT06066437, Nautilus Trial) and after external beam radiotherapy (NCT06105918).</p></div>\",\"PeriodicalId\":534,\"journal\":{\"name\":\"EJNMMI Radiopharmacy and Chemistry\",\"volume\":\"9 1\",\"pages\":\"\"},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-02-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ejnmmipharmchem.springeropen.com/counter/pdf/10.1186/s41181-024-00246-2\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Radiopharmacy and Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s41181-024-00246-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Radiopharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s41181-024-00246-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
Preclinical comparison of [177Lu]Lu-rhPSMA-10.1 and [177Lu]Lu-rhPSMA-10.2 for endoradiotherapy of prostate cancer: biodistribution and dosimetry studies
Background
Radiohybrid PSMA-targeted ligands (rhPSMA) have been introduced as a novel platform for theranostic applications. Among a variety of rhPSMA-ligands developed for radioligand therapy, two stereoisomers [177Lu]Lu-rhPSMA-10.1 and -10.2 have been synthesized and initially characterized in preclinical experiments with the aim to provide an optimized binding profile to human serum albumin, a reduction of charge, and thus accelerated kidney excretion, and unaffected or even improved tumor uptake. As both isomers showed similar in vitro characteristics and tumor uptake at 24 h post injection in tumor bearing mice and in order to identify the isomer with the most favorable pharmacokinetics for radioligand therapy, we carried out in-depth biodistribution and dosimetry studies in tumor-bearing and healthy mice.
Results
rhPSMA-10.1 and -10.2 were radiolabeled with lutetium-177 according to the established procedures of other DOTA-based PSMA ligands and displayed a high and comparable stability in all buffers and human serum (> 97%, 24 h). Biodistribution studies revealed fast clearance from the blood pool (0.3–0.6%ID/g at 1 h) and other background tissues within 48 h. Distinctive differences were found in the kidneys, where [177Lu]Lu-rhPSMA-10.1 displayed lower initial uptake and faster excretion kinetics compared to [177Lu]Lu-rhPSMA-10.2 expressed by a 1.5-fold and ninefold lower uptake value at 1 h and 24 h in healthy animals, respectively. Tumor uptake was comparable and in the range of 8.6–11.6%ID/g for both isomers over 24 h and was maintained up to 168 h at a level of 2.2 ± 0.8 and 4.1 ± 1.4%ID/g for [177Lu]Lu-rhPSMA-10.1 and [177Lu]Lu-rhPSMA-10.2, respectively.
Conclusion
Our preclinical data on biodistribution and dosimetry indicate a more favorable profile of [177Lu]Lu-rhPSMA-10.1 compared to [177Lu]Lu-rhPSMA-10.2 for PSMA-targeted radioligand therapy. [177Lu]Lu-rhPSMA-10.1 shows fast kidney clearance kinetics resulting in excellent tumor-to-organ ratios over a therapy relevant time course. Meanwhile, [177Lu]Lu-rhPSMA-10.1 is currently being investigated in clinical phase I/II studies in patients with mCRPC (NCT05413850), in patients with high-risk localized PC (NCT06066437, Nautilus Trial) and after external beam radiotherapy (NCT06105918).