{"title":"混凝土折叠板的抗震分析","authors":"Aqeel M. Hammood, David A. M. Jawad","doi":"10.33971/bjes.24.1.15","DOIUrl":null,"url":null,"abstract":"Concrete roof-folded plates have been shown to be inherently resilient to earthquakes, despite limited research on the reasons for their apparent seismic resistance. It is possible to make very thin, folded concrete plates because of their high structural efficiency. It is implicitly resistant to earthquake forces because thin, folded plat structures are relatively lightweight. Typically, folded plate structures are designed to perform under ideal gravity loads that are transported primarily as a result of membrane activity across the surface. It is possible for concrete-folded plate structures to be damaged by bending stresses when earthquakes induce unexpected horizontal forces. Through a parametric analysis of an 8-cm-thick concrete roof folded plate structure, it has been shown that thin concrete roof folded plates with a span < 30 m can be intrinsically earthquake-resistant. Despite having a low mass and high geometric stiffness, these buildings have fundamental frequencies that are substantially higher than those connected to seismic events that actually occur. This characteristic causes the folded plate to behave elastically under earthquake excitation without exceeding the maximum concrete strength. The vertical components of earthquake vibrations exert greater stress on a shallow, folded plate than the horizontal components. The values of the stresses imposed by the changing span were relatively small. They ranged from (3.5-4.4) MPa for the Landers earthquake, while for the El Centro earthquake, they ranged from (2.7-8.6) MPa. In addition, by raising the folded big plates and inclining them to a greater angle, it will become more common and lessen the harm caused by earthquake shaking in the vertical direction. In general, this paper aims to present an examination of earthquakes and their consequences for folded concrete plates.","PeriodicalId":150774,"journal":{"name":"Basrah journal for engineering science","volume":"18 23","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Seismic Analysis of Concrete Folded Plates\",\"authors\":\"Aqeel M. Hammood, David A. M. Jawad\",\"doi\":\"10.33971/bjes.24.1.15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Concrete roof-folded plates have been shown to be inherently resilient to earthquakes, despite limited research on the reasons for their apparent seismic resistance. It is possible to make very thin, folded concrete plates because of their high structural efficiency. It is implicitly resistant to earthquake forces because thin, folded plat structures are relatively lightweight. Typically, folded plate structures are designed to perform under ideal gravity loads that are transported primarily as a result of membrane activity across the surface. It is possible for concrete-folded plate structures to be damaged by bending stresses when earthquakes induce unexpected horizontal forces. Through a parametric analysis of an 8-cm-thick concrete roof folded plate structure, it has been shown that thin concrete roof folded plates with a span < 30 m can be intrinsically earthquake-resistant. Despite having a low mass and high geometric stiffness, these buildings have fundamental frequencies that are substantially higher than those connected to seismic events that actually occur. This characteristic causes the folded plate to behave elastically under earthquake excitation without exceeding the maximum concrete strength. The vertical components of earthquake vibrations exert greater stress on a shallow, folded plate than the horizontal components. The values of the stresses imposed by the changing span were relatively small. They ranged from (3.5-4.4) MPa for the Landers earthquake, while for the El Centro earthquake, they ranged from (2.7-8.6) MPa. In addition, by raising the folded big plates and inclining them to a greater angle, it will become more common and lessen the harm caused by earthquake shaking in the vertical direction. In general, this paper aims to present an examination of earthquakes and their consequences for folded concrete plates.\",\"PeriodicalId\":150774,\"journal\":{\"name\":\"Basrah journal for engineering science\",\"volume\":\"18 23\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Basrah journal for engineering science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33971/bjes.24.1.15\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Basrah journal for engineering science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33971/bjes.24.1.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
混凝土屋顶折叠板已被证明具有内在的抗震能力,尽管对其明显抗震的原因研究有限。由于混凝土折叠板具有很高的结构效率,因此可以制作非常薄的混凝土折叠板。由于薄折叠板结构相对较轻,因此它具有隐含的抗震性。通常情况下,折叠板结构设计用于承受理想的重力荷载,这些荷载主要是由于地表上的膜活动而产生的。当地震引起意外水平力时,混凝土折叠板结构有可能因弯曲应力而受损。通过对 8 厘米厚的混凝土屋顶折叠板结构进行参数分析,结果表明跨度小于 30 米的薄混凝土屋顶折叠板具有内在抗震性。尽管这些建筑物质量小、几何刚度大,但其基频却大大高于实际发生的地震事件的基频。这一特性使折叠板在地震激励下具有弹性行为,而不会超过混凝土的最大强度。地震振动的垂直分量对浅层折叠板施加的应力大于水平分量。跨度变化施加的应力值相对较小。Landers 地震的应力值为 (3.5-4.4) 兆帕,而 El Centro 地震的应力值为 (2.7-8.6) 兆帕。此外,通过提高折叠大板块并使其倾斜更大的角度,将使其变得更加普遍,并减轻地震在垂直方向上的摇晃所造成的危害。总之,本文旨在研究地震及其对折叠混凝土板的影响。
Concrete roof-folded plates have been shown to be inherently resilient to earthquakes, despite limited research on the reasons for their apparent seismic resistance. It is possible to make very thin, folded concrete plates because of their high structural efficiency. It is implicitly resistant to earthquake forces because thin, folded plat structures are relatively lightweight. Typically, folded plate structures are designed to perform under ideal gravity loads that are transported primarily as a result of membrane activity across the surface. It is possible for concrete-folded plate structures to be damaged by bending stresses when earthquakes induce unexpected horizontal forces. Through a parametric analysis of an 8-cm-thick concrete roof folded plate structure, it has been shown that thin concrete roof folded plates with a span < 30 m can be intrinsically earthquake-resistant. Despite having a low mass and high geometric stiffness, these buildings have fundamental frequencies that are substantially higher than those connected to seismic events that actually occur. This characteristic causes the folded plate to behave elastically under earthquake excitation without exceeding the maximum concrete strength. The vertical components of earthquake vibrations exert greater stress on a shallow, folded plate than the horizontal components. The values of the stresses imposed by the changing span were relatively small. They ranged from (3.5-4.4) MPa for the Landers earthquake, while for the El Centro earthquake, they ranged from (2.7-8.6) MPa. In addition, by raising the folded big plates and inclining them to a greater angle, it will become more common and lessen the harm caused by earthquake shaking in the vertical direction. In general, this paper aims to present an examination of earthquakes and their consequences for folded concrete plates.