{"title":"日本部分校舍外附式下部结构的抗震加固效果和振动测试","authors":"Liang Li, Hitoshi Marusaka, Yihui Zhang","doi":"10.21595/jve.2023.23543","DOIUrl":null,"url":null,"abstract":"In the long-term seismic work in Japan, an effective seismic reinforcement design system and reasonable seismic reinforcement technology have been developed, which is worth learning from. In this paper, the seismic reinforcement of a school building in Japan is taken as an example. Firstly, an overall reinforcement scheme of external prestressed precast concrete (PC) frame and steel brace is proposed. Then, based on the calculation results of seismic reinforcement and the ambient measurement before and after seismic reinforcement, the effectiveness and rationality of the seismic reinforcement method are analyzed. The results show that the seismic reinforcement method of attached substructures changes the original structural system, and solves the problems of excessive deformation and insufficient seismic performance. The reinforcement method improves the story stiffness of the structure, and the vibration period of simple harmonic motion after the implementation of seismic reinforcement is reduced by 0.845 times at most. The research results can provide reference for seismic reinforcement design and performance evaluation of existing school buildings.","PeriodicalId":49956,"journal":{"name":"Journal of Vibroengineering","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Seismic reinforcement effect and vibration test of externally attached substructures in a selected Japan school building\",\"authors\":\"Liang Li, Hitoshi Marusaka, Yihui Zhang\",\"doi\":\"10.21595/jve.2023.23543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the long-term seismic work in Japan, an effective seismic reinforcement design system and reasonable seismic reinforcement technology have been developed, which is worth learning from. In this paper, the seismic reinforcement of a school building in Japan is taken as an example. Firstly, an overall reinforcement scheme of external prestressed precast concrete (PC) frame and steel brace is proposed. Then, based on the calculation results of seismic reinforcement and the ambient measurement before and after seismic reinforcement, the effectiveness and rationality of the seismic reinforcement method are analyzed. The results show that the seismic reinforcement method of attached substructures changes the original structural system, and solves the problems of excessive deformation and insufficient seismic performance. The reinforcement method improves the story stiffness of the structure, and the vibration period of simple harmonic motion after the implementation of seismic reinforcement is reduced by 0.845 times at most. The research results can provide reference for seismic reinforcement design and performance evaluation of existing school buildings.\",\"PeriodicalId\":49956,\"journal\":{\"name\":\"Journal of Vibroengineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vibroengineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21595/jve.2023.23543\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vibroengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21595/jve.2023.23543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Seismic reinforcement effect and vibration test of externally attached substructures in a selected Japan school building
In the long-term seismic work in Japan, an effective seismic reinforcement design system and reasonable seismic reinforcement technology have been developed, which is worth learning from. In this paper, the seismic reinforcement of a school building in Japan is taken as an example. Firstly, an overall reinforcement scheme of external prestressed precast concrete (PC) frame and steel brace is proposed. Then, based on the calculation results of seismic reinforcement and the ambient measurement before and after seismic reinforcement, the effectiveness and rationality of the seismic reinforcement method are analyzed. The results show that the seismic reinforcement method of attached substructures changes the original structural system, and solves the problems of excessive deformation and insufficient seismic performance. The reinforcement method improves the story stiffness of the structure, and the vibration period of simple harmonic motion after the implementation of seismic reinforcement is reduced by 0.845 times at most. The research results can provide reference for seismic reinforcement design and performance evaluation of existing school buildings.
期刊介绍:
Journal of VIBROENGINEERING (JVE) ISSN 1392-8716 is a prestigious peer reviewed International Journal specializing in theoretical and practical aspects of Vibration Engineering. It is indexed in ESCI and other major databases. Published every 1.5 months (8 times yearly), the journal attracts attention from the International Engineering Community.