{"title":"调查便携式骨测量仪的可靠性和有效性","authors":"Eric Anderson, Sierra W. Malis, Anna J. Osterholtz, Molly K. Zuckerman","doi":"10.1017/aap.2023.33","DOIUrl":null,"url":null,"abstract":"\n Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.","PeriodicalId":7231,"journal":{"name":"Advances in Archaeological Practice","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigating the Reliability and Validity of the Portable Osteometric Device\",\"authors\":\"Eric Anderson, Sierra W. Malis, Anna J. Osterholtz, Molly K. Zuckerman\",\"doi\":\"10.1017/aap.2023.33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.\",\"PeriodicalId\":7231,\"journal\":{\"name\":\"Advances in Archaeological Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Archaeological Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/aap.2023.33\",\"RegionNum\":2,\"RegionCategory\":\"历史学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"N/A\",\"JCRName\":\"ARCHAEOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Archaeological Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/aap.2023.33","RegionNum":2,"RegionCategory":"历史学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"N/A","JCRName":"ARCHAEOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

对骨骼材料进行度量分析是分析和鉴定人类遗骸不可或缺的一部分,但一种常用的测量设备--测骨板--近年来却发展滞后。传统的测量板非常笨重,而且需要手动测量记录,可能会造成观察者内部和观察者之间的误差。为了解决这些局限性,我们测试了一种新型设备--便携式测骨仪第一版(PODv1)的可靠性、有效性和误差率。45 名志愿者使用 PODv1 和 PaleoTech 测骨板分三轮测量了四种骨骼元素。通过比较两种设备对胫骨、肱骨和股骨的测量结果,发现两者并无显著差异,但尺骨的最大长度确实存在差异,这可能是由于观察者对 PODv1 有关该元素的用户说明存在混淆。我们的结果表明,与传统的测骨板相比,PODv1 是一种可靠、有效的测量设备。虽然这两种设备都会产生校准、转录和观察者误差,但 PODv1 内置的飞行时间技术和无需手动记录的特点可能会限制这些误差。这些进步及其对骨测量数据收集准确性的潜在积极影响可能会对骨学、生物考古学、古病理学和法医人类学数据收集产生深远的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigating the Reliability and Validity of the Portable Osteometric Device
Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.70
自引率
21.40%
发文量
39
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信