{"title":"伊利扎罗夫外固定架。技术和解剖方面的考虑。","authors":"S A Green","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The Ilizarov external fixator can be safely applied if the surgeon is alert to the \"danger areas\" where the transfixion wires might penetrate a neurovascular structure. The basic principle of frame assembly and application require that the wires are never bent to reach the support rings; instead, the Ilizarov hardware is used to build up to the wires from the rings. The wires are then tensioned axially.</p>","PeriodicalId":77501,"journal":{"name":"Bulletin of the Hospital for Joint Diseases Orthopaedic Institute","volume":"48 1","pages":"28-35"},"PeriodicalIF":0.0000,"publicationDate":"1988-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ilizarov external fixation. Technical and anatomic considerations.\",\"authors\":\"S A Green\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Ilizarov external fixator can be safely applied if the surgeon is alert to the \\\"danger areas\\\" where the transfixion wires might penetrate a neurovascular structure. The basic principle of frame assembly and application require that the wires are never bent to reach the support rings; instead, the Ilizarov hardware is used to build up to the wires from the rings. The wires are then tensioned axially.</p>\",\"PeriodicalId\":77501,\"journal\":{\"name\":\"Bulletin of the Hospital for Joint Diseases Orthopaedic Institute\",\"volume\":\"48 1\",\"pages\":\"28-35\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Hospital for Joint Diseases Orthopaedic Institute\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Hospital for Joint Diseases Orthopaedic Institute","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Ilizarov external fixation. Technical and anatomic considerations.
The Ilizarov external fixator can be safely applied if the surgeon is alert to the "danger areas" where the transfixion wires might penetrate a neurovascular structure. The basic principle of frame assembly and application require that the wires are never bent to reach the support rings; instead, the Ilizarov hardware is used to build up to the wires from the rings. The wires are then tensioned axially.