{"title":"埃塞俄比亚电力西北地区系统风险识别","authors":"Mebratu Sintie Geremew, Yalew Gebru Workie, Lidia Bitew Techane","doi":"10.1007/s40998-024-00698-x","DOIUrl":null,"url":null,"abstract":"<p>Power system contingency is an operational state that can happen as a result of a system discontinuity and results in overall system voltage instability. The system has seen intermittent power outages in previous years, according to Ethiopia Electric Power. Parts of the grid system were disrupted during the event, and as a result, there was a partial blackout of the system. Therefore, research proposes identifying the system's exposure to lessen the likelihood of such accidents happening. The proposed method demonstrated on 15 bus system Northwest region of Ethiopia Electrical Power Network using DigSILENT software. System’s exposure was evaluated by using the voltage performance index and the overload performance index. The indices enable the evaluation of two distinct system stress signs, including voltage instability and overloads. Performance index data show that the BDII230 bus to the GoII bus line has highest performance index value (<b>4.9488</b>) from other for N-1 line outage circumstances. This indicates that BDII230 bus to the GoII is most dangerous line for interruption of Northwest region of Ethiopian Electric Power network. But the most sensitive bus for voltage limit violations on this condition are Gondar load bus and Metema load bus. Their voltage profile is 0.908 and 0.923 per unit, respectively. Also, for 50% load demand increasing conditions, Gondar load bus has highest performance index value (<b>20.2352</b>) compared to the other load buses and its voltage profile is 0.8879 per unit. So, applying performance index for Northwest region of Ethiopia Electric Power network is used to know the system performance such as voltage instability and overloading, for forecasting future operation and expansion planning of this area.</p>","PeriodicalId":49064,"journal":{"name":"Iranian Journal of Science and Technology-Transactions of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Identification of System Exposure for the Northwest Region of Ethiopian Electric Power\",\"authors\":\"Mebratu Sintie Geremew, Yalew Gebru Workie, Lidia Bitew Techane\",\"doi\":\"10.1007/s40998-024-00698-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Power system contingency is an operational state that can happen as a result of a system discontinuity and results in overall system voltage instability. The system has seen intermittent power outages in previous years, according to Ethiopia Electric Power. Parts of the grid system were disrupted during the event, and as a result, there was a partial blackout of the system. Therefore, research proposes identifying the system's exposure to lessen the likelihood of such accidents happening. The proposed method demonstrated on 15 bus system Northwest region of Ethiopia Electrical Power Network using DigSILENT software. System’s exposure was evaluated by using the voltage performance index and the overload performance index. The indices enable the evaluation of two distinct system stress signs, including voltage instability and overloads. Performance index data show that the BDII230 bus to the GoII bus line has highest performance index value (<b>4.9488</b>) from other for N-1 line outage circumstances. This indicates that BDII230 bus to the GoII is most dangerous line for interruption of Northwest region of Ethiopian Electric Power network. But the most sensitive bus for voltage limit violations on this condition are Gondar load bus and Metema load bus. Their voltage profile is 0.908 and 0.923 per unit, respectively. Also, for 50% load demand increasing conditions, Gondar load bus has highest performance index value (<b>20.2352</b>) compared to the other load buses and its voltage profile is 0.8879 per unit. So, applying performance index for Northwest region of Ethiopia Electric Power network is used to know the system performance such as voltage instability and overloading, for forecasting future operation and expansion planning of this area.</p>\",\"PeriodicalId\":49064,\"journal\":{\"name\":\"Iranian Journal of Science and Technology-Transactions of Electrical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Science and Technology-Transactions of Electrical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s40998-024-00698-x\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Science and Technology-Transactions of Electrical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40998-024-00698-x","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Identification of System Exposure for the Northwest Region of Ethiopian Electric Power
Power system contingency is an operational state that can happen as a result of a system discontinuity and results in overall system voltage instability. The system has seen intermittent power outages in previous years, according to Ethiopia Electric Power. Parts of the grid system were disrupted during the event, and as a result, there was a partial blackout of the system. Therefore, research proposes identifying the system's exposure to lessen the likelihood of such accidents happening. The proposed method demonstrated on 15 bus system Northwest region of Ethiopia Electrical Power Network using DigSILENT software. System’s exposure was evaluated by using the voltage performance index and the overload performance index. The indices enable the evaluation of two distinct system stress signs, including voltage instability and overloads. Performance index data show that the BDII230 bus to the GoII bus line has highest performance index value (4.9488) from other for N-1 line outage circumstances. This indicates that BDII230 bus to the GoII is most dangerous line for interruption of Northwest region of Ethiopian Electric Power network. But the most sensitive bus for voltage limit violations on this condition are Gondar load bus and Metema load bus. Their voltage profile is 0.908 and 0.923 per unit, respectively. Also, for 50% load demand increasing conditions, Gondar load bus has highest performance index value (20.2352) compared to the other load buses and its voltage profile is 0.8879 per unit. So, applying performance index for Northwest region of Ethiopia Electric Power network is used to know the system performance such as voltage instability and overloading, for forecasting future operation and expansion planning of this area.
期刊介绍:
Transactions of Electrical Engineering is to foster the growth of scientific research in all branches of electrical engineering and its related grounds and to provide a medium by means of which the fruits of these researches may be brought to the attentionof the world’s scientific communities.
The journal has the focus on the frontier topics in the theoretical, mathematical, numerical, experimental and scientific developments in electrical engineering as well
as applications of established techniques to new domains in various electical engineering disciplines such as:
Bio electric, Bio mechanics, Bio instrument, Microwaves, Wave Propagation, Communication Theory, Channel Estimation, radar & sonar system, Signal Processing, image processing, Artificial Neural Networks, Data Mining and Machine Learning, Fuzzy Logic and Systems, Fuzzy Control, Optimal & Robust ControlNavigation & Estimation Theory, Power Electronics & Drives, Power Generation & Management The editors will welcome papers from all professors and researchers from universities, research centers,
organizations, companies and industries from all over the world in the hope that this will advance the scientific standards of the journal and provide a channel of communication between Iranian Scholars and their colleague in other parts of the world.