Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce
{"title":"比较纤维扫描、剪切波弹性成像和剪切波频散测量在评估肝活检患者纤维化和坏死性炎症中的应用","authors":"Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce","doi":"10.1097/RUQ.0000000000000677","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).</p><p><strong>Materials and methods: </strong>In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.</p><p><strong>Results: </strong>Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).</p><p><strong>Conclusions: </strong>Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.\",\"authors\":\"Sinan Seyrek, Hakan Ayyildiz, Mesut Bulakci, Artur Salmaslioglu, Fatmatuzzehra Seyrek, Burak Gultekin, Bilger Cavus, Neslihan Berker, Melek Buyuk, Servet Yuce\",\"doi\":\"10.1097/RUQ.0000000000000677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).</p><p><strong>Materials and methods: </strong>In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.</p><p><strong>Results: </strong>Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).</p><p><strong>Conclusions: </strong>Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.</p>\",\"PeriodicalId\":49116,\"journal\":{\"name\":\"Ultrasound Quarterly\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Quarterly\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RUQ.0000000000000677\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000677","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.
Objective: Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).
Materials and methods: In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.
Results: Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).
Conclusions: Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.
期刊介绍:
Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography.