[儿童 EPInfant 量表的验证:估算和制作范例,使用 VO2 作为参考标准]。

IF 0.5 Q4 PEDIATRICS
Andrea González, Camila Aguayo, Claudio Báez, Iván Rodríguez-Núñez
{"title":"[儿童 EPInfant 量表的验证:估算和制作范例,使用 VO2 作为参考标准]。","authors":"Andrea González, Camila Aguayo, Claudio Báez, Iván Rodríguez-Núñez","doi":"10.32641/andespediatr.v94i6.4571","DOIUrl":null,"url":null,"abstract":"<p><p>The EPInfant scale was developed to quantify perceived exertion (PE) during exercise in children and adolescents.</p><p><strong>Objective: </strong>to determine the criterion validity of the EPInfant scale in children in the estimation and production paradigm considering oxygen consumption (VO2) as the reference standard.</p><p><strong>Subjects and method: </strong>Twenty healthy boys, aged 9.8 ± 1.5 years, were selected. They all performed an incremental shuttle walking test (ISWT) followed by a perceptual regulated-exercise test (PRET). VO2 and heart rate (HR) were recorded during both exercise tests. Average VO2 and HR values were considered as a perceptual reproduction test (PRT). EPInfant's validity in estimating the exercise intensity was evaluated by regression analysis between VO2, HR, and PE during ISWT and PRET.</p><p><strong>Results: </strong>All regression analysis models showed a robust positive relationship between PE and benchmarks (r2 > 0.90). The intraclass correlation coefficient for VO2 and HR was 0.89 (0.70 to 0.96) and 0.64 (0.08 to 0.86), respectively. Low mean discordance for VO2 and HR was observed in the Bland-Altman analysis.</p><p><strong>Conclusion: </strong>The EPInfant scale presented adequate criterion validity for estimating and regulating running exercise intensity in boys between 8 and 12 years.</p>","PeriodicalId":72196,"journal":{"name":"Andes pediatrica : revista Chilena de pediatria","volume":"94 6","pages":"713-720"},"PeriodicalIF":0.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Validiation of EPInfant scale in children: Estimation and production paradigms, using VO2 as reference criteria].\",\"authors\":\"Andrea González, Camila Aguayo, Claudio Báez, Iván Rodríguez-Núñez\",\"doi\":\"10.32641/andespediatr.v94i6.4571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The EPInfant scale was developed to quantify perceived exertion (PE) during exercise in children and adolescents.</p><p><strong>Objective: </strong>to determine the criterion validity of the EPInfant scale in children in the estimation and production paradigm considering oxygen consumption (VO2) as the reference standard.</p><p><strong>Subjects and method: </strong>Twenty healthy boys, aged 9.8 ± 1.5 years, were selected. They all performed an incremental shuttle walking test (ISWT) followed by a perceptual regulated-exercise test (PRET). VO2 and heart rate (HR) were recorded during both exercise tests. Average VO2 and HR values were considered as a perceptual reproduction test (PRT). EPInfant's validity in estimating the exercise intensity was evaluated by regression analysis between VO2, HR, and PE during ISWT and PRET.</p><p><strong>Results: </strong>All regression analysis models showed a robust positive relationship between PE and benchmarks (r2 > 0.90). The intraclass correlation coefficient for VO2 and HR was 0.89 (0.70 to 0.96) and 0.64 (0.08 to 0.86), respectively. Low mean discordance for VO2 and HR was observed in the Bland-Altman analysis.</p><p><strong>Conclusion: </strong>The EPInfant scale presented adequate criterion validity for estimating and regulating running exercise intensity in boys between 8 and 12 years.</p>\",\"PeriodicalId\":72196,\"journal\":{\"name\":\"Andes pediatrica : revista Chilena de pediatria\",\"volume\":\"94 6\",\"pages\":\"713-720\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Andes pediatrica : revista Chilena de pediatria\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32641/andespediatr.v94i6.4571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Andes pediatrica : revista Chilena de pediatria","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32641/andespediatr.v94i6.4571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:以耗氧量(VO2)为参考标准,确定 EPInfant 量表在儿童估计和生产范式中的标准有效性:选取 20 名健康男孩,年龄为 9.8 ± 1.5 岁。他们都进行了增量穿梭步行测试(ISWT),然后进行了感知调节运动测试(PRET)。在这两项运动测试中都记录了 VO2 和心率(HR)。VO2和心率的平均值被视为感知再现测试(PRT)。通过对 ISWT 和 PRET 期间的 VO2、HR 和 PE 进行回归分析,评估 EPInfant 在估计运动强度方面的有效性:所有回归分析模型均显示 PE 与基准之间存在稳健的正相关关系(r2 > 0.90)。VO2 和 HR 的类内相关系数分别为 0.89(0.70-0.96)和 0.64(0.08-0.86)。在Bland-Altman分析中观察到,VO2和HR的平均不一致性较低:EPInfant量表在估计和调节8至12岁男孩的跑步运动强度方面具有充分的标准有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Validiation of EPInfant scale in children: Estimation and production paradigms, using VO2 as reference criteria].

The EPInfant scale was developed to quantify perceived exertion (PE) during exercise in children and adolescents.

Objective: to determine the criterion validity of the EPInfant scale in children in the estimation and production paradigm considering oxygen consumption (VO2) as the reference standard.

Subjects and method: Twenty healthy boys, aged 9.8 ± 1.5 years, were selected. They all performed an incremental shuttle walking test (ISWT) followed by a perceptual regulated-exercise test (PRET). VO2 and heart rate (HR) were recorded during both exercise tests. Average VO2 and HR values were considered as a perceptual reproduction test (PRT). EPInfant's validity in estimating the exercise intensity was evaluated by regression analysis between VO2, HR, and PE during ISWT and PRET.

Results: All regression analysis models showed a robust positive relationship between PE and benchmarks (r2 > 0.90). The intraclass correlation coefficient for VO2 and HR was 0.89 (0.70 to 0.96) and 0.64 (0.08 to 0.86), respectively. Low mean discordance for VO2 and HR was observed in the Bland-Altman analysis.

Conclusion: The EPInfant scale presented adequate criterion validity for estimating and regulating running exercise intensity in boys between 8 and 12 years.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信