{"title":"脉冲 FDA 雷达中的信号设计和杂波存在时的多目标探测","authors":"Marziye Golabi, Abbas Sheikhi, Mehrzad Biguesh","doi":"10.1007/s40998-023-00693-8","DOIUrl":null,"url":null,"abstract":"<p>The small frequency offset across the array elements in frequency diverse array (FDA) radars leads to the range-angle-time dependent beampattern of FDA radars which is different from the angle-only dependent beampattern of the traditional phased arrays. In this paper, a simple signal model for the received signal in pulsed FDA radars is derived and it is shown that the transmitted signal is amplitude modulated by a digital sinc function which depends on the angle of the scatterer. Then, a signal design framework is presented based on the derived model in which it is represented that how the angular coverage zone and range resolution depend on pulsed FDA radar parameters. After that an iterative low complexity constant false alarm rate (CFAR) Generalized Likelihood Ratio Test (GLRT)-based detector for general FDA radars is derived to detect multiple targets in the presence of clutter and noise. The performance of the proposed detection algorithm is verified by simulation results.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Signal Design and Multiple Target Detection in Presence of Clutter in Pulsed FDA Radar\",\"authors\":\"Marziye Golabi, Abbas Sheikhi, Mehrzad Biguesh\",\"doi\":\"10.1007/s40998-023-00693-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The small frequency offset across the array elements in frequency diverse array (FDA) radars leads to the range-angle-time dependent beampattern of FDA radars which is different from the angle-only dependent beampattern of the traditional phased arrays. In this paper, a simple signal model for the received signal in pulsed FDA radars is derived and it is shown that the transmitted signal is amplitude modulated by a digital sinc function which depends on the angle of the scatterer. Then, a signal design framework is presented based on the derived model in which it is represented that how the angular coverage zone and range resolution depend on pulsed FDA radar parameters. After that an iterative low complexity constant false alarm rate (CFAR) Generalized Likelihood Ratio Test (GLRT)-based detector for general FDA radars is derived to detect multiple targets in the presence of clutter and noise. The performance of the proposed detection algorithm is verified by simulation results.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s40998-023-00693-8\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40998-023-00693-8","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
频率多样化阵列(FDA)雷达中各阵元之间的频率偏移较小,这导致 FDA 雷达具有与射程-角度-时间相关的蜂鸣模式,与传统相控阵中仅与角度相关的蜂鸣模式不同。本文推导了脉冲 FDA 雷达接收信号的简单信号模型,并证明发射信号的振幅由数字 sinc 函数调制,该函数取决于散射体的角度。然后,根据推导出的模型提出了一个信号设计框架,其中说明了角度覆盖区和测距分辨率如何取决于脉冲 FDA 雷达参数。然后,为一般 FDA 雷达推导出一种基于广义似然比检验(GLRT)的迭代式低复杂度恒定误报率(CFAR)检测器,用于在杂波和噪声存在的情况下检测多个目标。仿真结果验证了所提检测算法的性能。
Signal Design and Multiple Target Detection in Presence of Clutter in Pulsed FDA Radar
The small frequency offset across the array elements in frequency diverse array (FDA) radars leads to the range-angle-time dependent beampattern of FDA radars which is different from the angle-only dependent beampattern of the traditional phased arrays. In this paper, a simple signal model for the received signal in pulsed FDA radars is derived and it is shown that the transmitted signal is amplitude modulated by a digital sinc function which depends on the angle of the scatterer. Then, a signal design framework is presented based on the derived model in which it is represented that how the angular coverage zone and range resolution depend on pulsed FDA radar parameters. After that an iterative low complexity constant false alarm rate (CFAR) Generalized Likelihood Ratio Test (GLRT)-based detector for general FDA radars is derived to detect multiple targets in the presence of clutter and noise. The performance of the proposed detection algorithm is verified by simulation results.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.