Michael E. Mitchell MD , Ronald K. Woods MD, PhD , Tracy R. Geoffrion MD, MPH , Mami Sow MD
{"title":"肺自体移植晚期扩张:我们能让好手术变得更好吗?得到支持的罗斯","authors":"Michael E. Mitchell MD , Ronald K. Woods MD, PhD , Tracy R. Geoffrion MD, MPH , Mami Sow MD","doi":"10.1053/j.pcsu.2024.01.007","DOIUrl":null,"url":null,"abstract":"<div><p>The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (<em>P</em> = 0.002), aortic sinus diameter (<em>P</em> = 0.001) change in left ventricular function (<em>P</em> = 0.039) and change in aortic insufficiency (<em>P</em> = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.</p></div>","PeriodicalId":38774,"journal":{"name":"Pediatric Cardiac Surgery Annual","volume":"27 ","pages":"Pages 47-51"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Late Pulmonary Autograft Dilation: Can We Make a Good Operation Great? The Supported Ross\",\"authors\":\"Michael E. Mitchell MD , Ronald K. Woods MD, PhD , Tracy R. Geoffrion MD, MPH , Mami Sow MD\",\"doi\":\"10.1053/j.pcsu.2024.01.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (<em>P</em> = 0.002), aortic sinus diameter (<em>P</em> = 0.001) change in left ventricular function (<em>P</em> = 0.039) and change in aortic insufficiency (<em>P</em> = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.</p></div>\",\"PeriodicalId\":38774,\"journal\":{\"name\":\"Pediatric Cardiac Surgery Annual\",\"volume\":\"27 \",\"pages\":\"Pages 47-51\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Cardiac Surgery Annual\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1092912624000048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Cardiac Surgery Annual","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1092912624000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Late Pulmonary Autograft Dilation: Can We Make a Good Operation Great? The Supported Ross
The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (P = 0.002), aortic sinus diameter (P = 0.001) change in left ventricular function (P = 0.039) and change in aortic insufficiency (P = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.
期刊介绍:
The Pediatric Cardiac Surgery Annual is a companion to Seminars in Thoracic and Cardiovascular Surgery . Together with the Seminars, the Annual provides complete coverage of the specialty by focusing on important developments in pediatric cardiac surgery. Each annual volume has an expert guest editor who invites prominent surgeons to review the areas of greatest change in pediatric cardiac surgery during the year. Topics include 1) Complete Atrioventricular Canal; 2) New Concepts of Cardiac Anatomy and Function -- The Helical Heart; 3) Valve Reconstruction (Replacement) in Congenital Heart Disease; 4) Evolving Developments in Congenital Heart Surgery.