利用分光光度法同时测定水溶液中的铁和铜

Abbas. H. Al-Shukry, Zain E. Mansor, Nada. A. Abd Al -Hussein Al -Hussein
{"title":"利用分光光度法同时测定水溶液中的铁和铜","authors":"Abbas. H. Al-Shukry, Zain E. Mansor, Nada. A. Abd Al -Hussein Al -Hussein","doi":"10.36371/port.2024.1.3","DOIUrl":null,"url":null,"abstract":"Iron and copper mixtures were quantitatively determined in aqueous solutions for the first time using the analytical method in this approach with the aid of T60U Spectrophotometer. The method is so simple, fast, economic, and can be carried out easily on a bench. The absorbencies for iron, copper and iron-copper mixtures in aqueous solution were measured using T60U adopted with UVWin6 software UV -VIS Spectrometer (pg instruments United Kingdom) by filling two 5 ml quartz cells of dimensions 1*1*5 cm, the first is filled with the blank solution which is a solution containing all the constituents of the sample except iron and copper and the other quartz cell is filled with the stock solution iron and/or copper under investigation. Absorbency of iron was determined by setting T60U spectrometer wavelength at 504 nm, meanwhile for copper absorbency measurements the apparatus is set at 304 nm. Iron, copper, and iron-copper mixture calibration curves were of very high accuracy with the least linear regression value of ≤ 1, i, e the measured data were of relative standard deviation value (RSD) of ≤ 1.5%.","PeriodicalId":502904,"journal":{"name":"Journal Port Science Research","volume":"112 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Determination of Iron and Copper in Aqueous Solution Using Spectrophotometry\",\"authors\":\"Abbas. H. Al-Shukry, Zain E. Mansor, Nada. A. Abd Al -Hussein Al -Hussein\",\"doi\":\"10.36371/port.2024.1.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Iron and copper mixtures were quantitatively determined in aqueous solutions for the first time using the analytical method in this approach with the aid of T60U Spectrophotometer. The method is so simple, fast, economic, and can be carried out easily on a bench. The absorbencies for iron, copper and iron-copper mixtures in aqueous solution were measured using T60U adopted with UVWin6 software UV -VIS Spectrometer (pg instruments United Kingdom) by filling two 5 ml quartz cells of dimensions 1*1*5 cm, the first is filled with the blank solution which is a solution containing all the constituents of the sample except iron and copper and the other quartz cell is filled with the stock solution iron and/or copper under investigation. Absorbency of iron was determined by setting T60U spectrometer wavelength at 504 nm, meanwhile for copper absorbency measurements the apparatus is set at 304 nm. Iron, copper, and iron-copper mixture calibration curves were of very high accuracy with the least linear regression value of ≤ 1, i, e the measured data were of relative standard deviation value (RSD) of ≤ 1.5%.\",\"PeriodicalId\":502904,\"journal\":{\"name\":\"Journal Port Science Research\",\"volume\":\"112 22\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal Port Science Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36371/port.2024.1.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal Port Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36371/port.2024.1.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在 T60U 分光光度计的帮助下,首次使用本方法中的分析方法对水溶液中的铁和铜混合物进行了定量测定。该方法简单、快速、经济,可在工作台上轻松完成。使用配有 UVWin6 软件的 T60U 紫外可见分光光度计(英国 pg 仪器公司)测量了水溶液中铁、铜和铁铜混合物的吸光度,方法是在两个尺寸为 1*1*5 厘米的 5 毫升石英池中分别注入空白溶液,即含有除铁和铜以外的所有样品成分的溶液,在另一个石英池中注入所研究的铁和/或铜的储备溶液。铁的吸收率是通过将 T60U 光谱仪的波长设置在 504 纳米来测定的,而铜的吸收率测量仪器设置在 304 纳米。铁、铜和铁铜混合物的校准曲线精度非常高,最小线性回归值≤1,即测量数据的相对标准偏差值(RSD)≤1.5%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simultaneous Determination of Iron and Copper in Aqueous Solution Using Spectrophotometry
Iron and copper mixtures were quantitatively determined in aqueous solutions for the first time using the analytical method in this approach with the aid of T60U Spectrophotometer. The method is so simple, fast, economic, and can be carried out easily on a bench. The absorbencies for iron, copper and iron-copper mixtures in aqueous solution were measured using T60U adopted with UVWin6 software UV -VIS Spectrometer (pg instruments United Kingdom) by filling two 5 ml quartz cells of dimensions 1*1*5 cm, the first is filled with the blank solution which is a solution containing all the constituents of the sample except iron and copper and the other quartz cell is filled with the stock solution iron and/or copper under investigation. Absorbency of iron was determined by setting T60U spectrometer wavelength at 504 nm, meanwhile for copper absorbency measurements the apparatus is set at 304 nm. Iron, copper, and iron-copper mixture calibration curves were of very high accuracy with the least linear regression value of ≤ 1, i, e the measured data were of relative standard deviation value (RSD) of ≤ 1.5%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信