{"title":"伊拉克 2 型糖尿病患者血清中的铬、铜和锰水平与血糖水平的相关性","authors":"Ahmed Zaid, Hedef Dhafer Al-Yassin","doi":"10.32007/jfacmedbagdad.2126","DOIUrl":null,"url":null,"abstract":"Correlation of Serum levels of Chromium, Copper, and Manganese with the Glucose levels in Type 2 Diabetes Mellitus in Ira\nBackground: The metabolism of many trace elements such as chromium, copper, and manganese were reported to be altered in type 2 diabetes militates. This element may have specific roles in the pathogenesis and progress of this disease.\nObjectives: To evaluate the serum levels of copper, chromium, and manganese in type 2 diabetic patients in Iraq. \nPatients and Methods: This case-control study included 100 type 2 diabetic patients, 35-60 years old, with high BMI as cases, and 100 non-diabetic subjects as controls who were healthy volunteers not suffering from type 2 diabetes (staff and student). The data was collected from October 2022 until January 2023. The cases were seen in the Diabetes Consultation Unit / Baghdad Teaching Hospital / Medical City. Serum chromium, copper, and manganese were measured using atomic absorption. ELISA was used to test for insulin. spectrophotometry to measure glucose and HPLC was used to measure whole-blood HbA1c. Insulin resistance was calculated using the semi-empirical formula: HOMA-IR = glucose * insulin / 405 (glucose in mg/dl). To test for the difference between means of numerical data across several parameters, ANOVA tests were utilized. Pearson’s. correlation was used to test the correlation between variables.\nResults: Diabetics had higher HbA1c, serum copper (P value<0.01), and blood glucose than healthy controls. Compared to controls, diabetics had lower serum chromium (P value<0.01) and manganese (P value < 0.01). In diabetics, chromium and manganese are highly negatively correlated with insulin resistance. Copper levels increase with increasing insulin resistance. Insulin levels were greater in type 2 diabetics (18.6 ± 4.1mlU/L) than in the control (6.2 ± 1.3) (p <0.01).\nConclusions: Serum copper was high while serum chromium and manganese were low in type 2 diabetics. that indicates that these elements may have a role in the occurrence and development of type 2 diabetes.\nReceived: May, 2023\nAccepted: Oct., 2023\nPublished: Jan., 2024\n ","PeriodicalId":516152,"journal":{"name":"Journal of the Faculty of Medicine Baghdad","volume":"125 13","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation of Serum levels of Chromium, Copper, and Manganese with the Glucose levels in Type 2 Diabetes Mellitus in Iraq\",\"authors\":\"Ahmed Zaid, Hedef Dhafer Al-Yassin\",\"doi\":\"10.32007/jfacmedbagdad.2126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Correlation of Serum levels of Chromium, Copper, and Manganese with the Glucose levels in Type 2 Diabetes Mellitus in Ira\\nBackground: The metabolism of many trace elements such as chromium, copper, and manganese were reported to be altered in type 2 diabetes militates. This element may have specific roles in the pathogenesis and progress of this disease.\\nObjectives: To evaluate the serum levels of copper, chromium, and manganese in type 2 diabetic patients in Iraq. \\nPatients and Methods: This case-control study included 100 type 2 diabetic patients, 35-60 years old, with high BMI as cases, and 100 non-diabetic subjects as controls who were healthy volunteers not suffering from type 2 diabetes (staff and student). The data was collected from October 2022 until January 2023. The cases were seen in the Diabetes Consultation Unit / Baghdad Teaching Hospital / Medical City. Serum chromium, copper, and manganese were measured using atomic absorption. ELISA was used to test for insulin. spectrophotometry to measure glucose and HPLC was used to measure whole-blood HbA1c. Insulin resistance was calculated using the semi-empirical formula: HOMA-IR = glucose * insulin / 405 (glucose in mg/dl). To test for the difference between means of numerical data across several parameters, ANOVA tests were utilized. Pearson’s. correlation was used to test the correlation between variables.\\nResults: Diabetics had higher HbA1c, serum copper (P value<0.01), and blood glucose than healthy controls. Compared to controls, diabetics had lower serum chromium (P value<0.01) and manganese (P value < 0.01). In diabetics, chromium and manganese are highly negatively correlated with insulin resistance. Copper levels increase with increasing insulin resistance. Insulin levels were greater in type 2 diabetics (18.6 ± 4.1mlU/L) than in the control (6.2 ± 1.3) (p <0.01).\\nConclusions: Serum copper was high while serum chromium and manganese were low in type 2 diabetics. that indicates that these elements may have a role in the occurrence and development of type 2 diabetes.\\nReceived: May, 2023\\nAccepted: Oct., 2023\\nPublished: Jan., 2024\\n \",\"PeriodicalId\":516152,\"journal\":{\"name\":\"Journal of the Faculty of Medicine Baghdad\",\"volume\":\"125 13\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Faculty of Medicine Baghdad\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32007/jfacmedbagdad.2126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Faculty of Medicine Baghdad","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32007/jfacmedbagdad.2126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Correlation of Serum levels of Chromium, Copper, and Manganese with the Glucose levels in Type 2 Diabetes Mellitus in Iraq
Correlation of Serum levels of Chromium, Copper, and Manganese with the Glucose levels in Type 2 Diabetes Mellitus in Ira
Background: The metabolism of many trace elements such as chromium, copper, and manganese were reported to be altered in type 2 diabetes militates. This element may have specific roles in the pathogenesis and progress of this disease.
Objectives: To evaluate the serum levels of copper, chromium, and manganese in type 2 diabetic patients in Iraq.
Patients and Methods: This case-control study included 100 type 2 diabetic patients, 35-60 years old, with high BMI as cases, and 100 non-diabetic subjects as controls who were healthy volunteers not suffering from type 2 diabetes (staff and student). The data was collected from October 2022 until January 2023. The cases were seen in the Diabetes Consultation Unit / Baghdad Teaching Hospital / Medical City. Serum chromium, copper, and manganese were measured using atomic absorption. ELISA was used to test for insulin. spectrophotometry to measure glucose and HPLC was used to measure whole-blood HbA1c. Insulin resistance was calculated using the semi-empirical formula: HOMA-IR = glucose * insulin / 405 (glucose in mg/dl). To test for the difference between means of numerical data across several parameters, ANOVA tests were utilized. Pearson’s. correlation was used to test the correlation between variables.
Results: Diabetics had higher HbA1c, serum copper (P value<0.01), and blood glucose than healthy controls. Compared to controls, diabetics had lower serum chromium (P value<0.01) and manganese (P value < 0.01). In diabetics, chromium and manganese are highly negatively correlated with insulin resistance. Copper levels increase with increasing insulin resistance. Insulin levels were greater in type 2 diabetics (18.6 ± 4.1mlU/L) than in the control (6.2 ± 1.3) (p <0.01).
Conclusions: Serum copper was high while serum chromium and manganese were low in type 2 diabetics. that indicates that these elements may have a role in the occurrence and development of type 2 diabetes.
Received: May, 2023
Accepted: Oct., 2023
Published: Jan., 2024