密闭空间内二氧化碳含量的数学建模。

IF 1.8 Q2 ENGINEERING, MULTIDISCIPLINARY
Lincan Yan, Dave S Yantek, Cory R DeGennaro, Rohan D Fernando
{"title":"密闭空间内二氧化碳含量的数学建模。","authors":"Lincan Yan, Dave S Yantek, Cory R DeGennaro, Rohan D Fernando","doi":"10.1115/1.4055389","DOIUrl":null,"url":null,"abstract":"<p><p>Federal regulations require refuge alternatives (RAs) in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. A breathable air supply is among those requirements. For built-in-place (BIP) RAs, a borehole air supply (BAS) is commonly used to supply fresh air from the surface. Federal regulations require that such a BAS must supply fresh air at 12.5 cfm or more per person to maintain the oxygen concentration between 18.5% and 23% and carbon dioxide level below the 1% limit specified. However, it is unclear whether 12.5 cfm is indeed needed to maintain this carbon dioxide level. The minimal fresh air flow (FAF) rate needed to maintain the 1% CO<sub>2</sub> level will depend on multiple factors, including the number of people and the volume of the BIP RA. In the past, to predict the interior CO<sub>2</sub> concentration in an occupied RA, 96-h tests were performed using a physical human breathing simulator. However, given the infinite possibility of the combinations (number of people, size of the BIP RA), it would be impractical to fully investigate the range of parameters that can affect the CO<sub>2</sub> concentration using physical tests. In this paper, researchers at the National Institute for Occupational Safety and Health (NIOSH) developed a model that can predict how the %CO<sub>2</sub> in an occupied confined space changes with time given the number of occupants and the FAF rate. The model was then compared to and validated with test data. The benchmarked model can be used to predict the %CO<sub>2</sub> for any number of people and FAF rate without conducting a 96-h test. The methodology used in this model can also be used to estimate other gas levels within a confined space.</p>","PeriodicalId":44694,"journal":{"name":"ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part B-Mechanical Engineering","volume":"9 2","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10772919/pdf/","citationCount":"0","resultStr":"{\"title\":\"Mathematical Modeling for Carbon Dioxide Level Within Confined Spaces.\",\"authors\":\"Lincan Yan, Dave S Yantek, Cory R DeGennaro, Rohan D Fernando\",\"doi\":\"10.1115/1.4055389\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Federal regulations require refuge alternatives (RAs) in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. A breathable air supply is among those requirements. For built-in-place (BIP) RAs, a borehole air supply (BAS) is commonly used to supply fresh air from the surface. Federal regulations require that such a BAS must supply fresh air at 12.5 cfm or more per person to maintain the oxygen concentration between 18.5% and 23% and carbon dioxide level below the 1% limit specified. However, it is unclear whether 12.5 cfm is indeed needed to maintain this carbon dioxide level. The minimal fresh air flow (FAF) rate needed to maintain the 1% CO<sub>2</sub> level will depend on multiple factors, including the number of people and the volume of the BIP RA. In the past, to predict the interior CO<sub>2</sub> concentration in an occupied RA, 96-h tests were performed using a physical human breathing simulator. However, given the infinite possibility of the combinations (number of people, size of the BIP RA), it would be impractical to fully investigate the range of parameters that can affect the CO<sub>2</sub> concentration using physical tests. In this paper, researchers at the National Institute for Occupational Safety and Health (NIOSH) developed a model that can predict how the %CO<sub>2</sub> in an occupied confined space changes with time given the number of occupants and the FAF rate. The model was then compared to and validated with test data. The benchmarked model can be used to predict the %CO<sub>2</sub> for any number of people and FAF rate without conducting a 96-h test. The methodology used in this model can also be used to estimate other gas levels within a confined space.</p>\",\"PeriodicalId\":44694,\"journal\":{\"name\":\"ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part B-Mechanical Engineering\",\"volume\":\"9 2\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10772919/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part B-Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4055389\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems Part B-Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4055389","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

联邦法规要求煤矿地下避难所(RA)在无法逃生的情况下为被困矿工提供维持生命的环境。可呼吸的空气供应是其中一项要求。对于内置式(BIP)避难硐室,通常使用钻孔供气装置(BAS)从地面提供新鲜空气。联邦法规规定,这种钻孔供气系统必须为每人提供 12.5 立方英尺/分或更多的新鲜空气,以保持氧气浓度在 18.5% 至 23% 之间,二氧化碳水平低于规定的 1% 限值。然而,是否真的需要 12.5 立方英尺/分钟来维持这一二氧化碳水平,目前尚不清楚。维持 1% 二氧化碳浓度所需的最小新鲜空气流量(FAF)取决于多种因素,包括人数和 BIP RA 的容积。过去,为了预测有人居住的室内空气中的二氧化碳浓度,曾使用物理人体呼吸模拟器进行过 96 小时的测试。然而,考虑到组合的无限可能性(人数、BIP RA 的大小),使用物理测试来全面研究可能影响二氧化碳浓度的参数范围是不切实际的。在本文中,美国国家职业安全与健康研究所 (NIOSH) 的研究人员建立了一个模型,该模型可以在考虑到人员数量和 FAF 率的情况下,预测被占用密闭空间中 CO2 的百分比是如何随时间变化的。该模型随后与测试数据进行了比较和验证。基准模型可用于预测任何人数和 FAF 率下的二氧化碳浓度,而无需进行 96 小时的测试。该模型中使用的方法也可用于估算密闭空间内的其他气体含量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mathematical Modeling for Carbon Dioxide Level Within Confined Spaces.

Federal regulations require refuge alternatives (RAs) in underground coal mines to provide a life-sustaining environment for miners trapped underground when escape is impossible. A breathable air supply is among those requirements. For built-in-place (BIP) RAs, a borehole air supply (BAS) is commonly used to supply fresh air from the surface. Federal regulations require that such a BAS must supply fresh air at 12.5 cfm or more per person to maintain the oxygen concentration between 18.5% and 23% and carbon dioxide level below the 1% limit specified. However, it is unclear whether 12.5 cfm is indeed needed to maintain this carbon dioxide level. The minimal fresh air flow (FAF) rate needed to maintain the 1% CO2 level will depend on multiple factors, including the number of people and the volume of the BIP RA. In the past, to predict the interior CO2 concentration in an occupied RA, 96-h tests were performed using a physical human breathing simulator. However, given the infinite possibility of the combinations (number of people, size of the BIP RA), it would be impractical to fully investigate the range of parameters that can affect the CO2 concentration using physical tests. In this paper, researchers at the National Institute for Occupational Safety and Health (NIOSH) developed a model that can predict how the %CO2 in an occupied confined space changes with time given the number of occupants and the FAF rate. The model was then compared to and validated with test data. The benchmarked model can be used to predict the %CO2 for any number of people and FAF rate without conducting a 96-h test. The methodology used in this model can also be used to estimate other gas levels within a confined space.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
13.60%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信