Vivek C. Mehta, Sanjay A. Chandrasekhar, Donald L Quimby, Ajay Bhandari, Victoria Mazo, Alexander D. Glaser, David Z. Rose, Bibhu D Mohanty
{"title":"经导管主动脉瓣置换术中的脑保护:随机试验数据的回顾与当代评估","authors":"Vivek C. Mehta, Sanjay A. Chandrasekhar, Donald L Quimby, Ajay Bhandari, Victoria Mazo, Alexander D. Glaser, David Z. Rose, Bibhu D Mohanty","doi":"10.1177/19418744231225680","DOIUrl":null,"url":null,"abstract":"As the population has aged and as aortic valve therapies have evolved, the use of trans-catheter aortic valve replacement (TAVR) has grown dramatically over the past decade. A well-known complication of percutaneous cardiac intervention is embolic phenomena, and TAVR is among the highest risk procedures for clinical and subclinical stroke. As indications for TAVR expand to lower-risk and ultimately younger patients, the long-term consequences of stroke are amplified. Cerebral embolic protection (CEP) devices have taken a on unique preventative role following the Food and Drug Administration approval of the SentinelTM Cerebral Protection System (CPS). More recently, the PROTECTED TAVR study has spurred extensive debate in the neuro-cardiac community. In this review we describe the contemporary literature regarding stroke risk associated with TAVR, the history and role of CEP devices, a PROTECTED TAVR sub-group analysis, and implications for next steps in the field. Lastly, we explore the unique need for CEP in a younger TAVR population, as well as directions for future research.","PeriodicalId":509682,"journal":{"name":"The Neurohospitalist","volume":"95 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cerebral Protection in Trans-Catheter Aortic Valve Replacement: Review and Contemporary Assessment of Randomized Trial Data\",\"authors\":\"Vivek C. Mehta, Sanjay A. Chandrasekhar, Donald L Quimby, Ajay Bhandari, Victoria Mazo, Alexander D. Glaser, David Z. Rose, Bibhu D Mohanty\",\"doi\":\"10.1177/19418744231225680\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As the population has aged and as aortic valve therapies have evolved, the use of trans-catheter aortic valve replacement (TAVR) has grown dramatically over the past decade. A well-known complication of percutaneous cardiac intervention is embolic phenomena, and TAVR is among the highest risk procedures for clinical and subclinical stroke. As indications for TAVR expand to lower-risk and ultimately younger patients, the long-term consequences of stroke are amplified. Cerebral embolic protection (CEP) devices have taken a on unique preventative role following the Food and Drug Administration approval of the SentinelTM Cerebral Protection System (CPS). More recently, the PROTECTED TAVR study has spurred extensive debate in the neuro-cardiac community. In this review we describe the contemporary literature regarding stroke risk associated with TAVR, the history and role of CEP devices, a PROTECTED TAVR sub-group analysis, and implications for next steps in the field. Lastly, we explore the unique need for CEP in a younger TAVR population, as well as directions for future research.\",\"PeriodicalId\":509682,\"journal\":{\"name\":\"The Neurohospitalist\",\"volume\":\"95 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Neurohospitalist\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/19418744231225680\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Neurohospitalist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19418744231225680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cerebral Protection in Trans-Catheter Aortic Valve Replacement: Review and Contemporary Assessment of Randomized Trial Data
As the population has aged and as aortic valve therapies have evolved, the use of trans-catheter aortic valve replacement (TAVR) has grown dramatically over the past decade. A well-known complication of percutaneous cardiac intervention is embolic phenomena, and TAVR is among the highest risk procedures for clinical and subclinical stroke. As indications for TAVR expand to lower-risk and ultimately younger patients, the long-term consequences of stroke are amplified. Cerebral embolic protection (CEP) devices have taken a on unique preventative role following the Food and Drug Administration approval of the SentinelTM Cerebral Protection System (CPS). More recently, the PROTECTED TAVR study has spurred extensive debate in the neuro-cardiac community. In this review we describe the contemporary literature regarding stroke risk associated with TAVR, the history and role of CEP devices, a PROTECTED TAVR sub-group analysis, and implications for next steps in the field. Lastly, we explore the unique need for CEP in a younger TAVR population, as well as directions for future research.