Wenlong Yao, Chunbo Pei, R. Chi, Wei Shao, Boyang Li
{"title":"基于 VSG 算法和 MFAC 的商船逆变器船舶微电网预同步控制","authors":"Wenlong Yao, Chunbo Pei, R. Chi, Wei Shao, Boyang Li","doi":"10.1177/01423312231198922","DOIUrl":null,"url":null,"abstract":"The paper studies a presynchronization control of grid connection for large merchant marine microgrid inverters. We present a virtual synchronous generator (VSG) algorithm with model-free adaptive control (MFAC) to optimize the stable grid connection of ship microgrid and shore-to-ship power. To solve poor precision of presynchronization control under nonideal ship microgrid condition, an MFAC controller and its presynchronization method are developed for grid connection of ship-distributed generation inverters. The proposed presynchronization control method effectively avoids a high transient overcurrent and achieves a seamless grid connection to different types of shore power. The simulation results verify the effectiveness of the proposed control method.","PeriodicalId":49426,"journal":{"name":"Transactions of the Institute of Measurement and Control","volume":"9 12","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Presynchronization control for ship microgrid of merchant marine inverters based on VSG algorithm with MFAC\",\"authors\":\"Wenlong Yao, Chunbo Pei, R. Chi, Wei Shao, Boyang Li\",\"doi\":\"10.1177/01423312231198922\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper studies a presynchronization control of grid connection for large merchant marine microgrid inverters. We present a virtual synchronous generator (VSG) algorithm with model-free adaptive control (MFAC) to optimize the stable grid connection of ship microgrid and shore-to-ship power. To solve poor precision of presynchronization control under nonideal ship microgrid condition, an MFAC controller and its presynchronization method are developed for grid connection of ship-distributed generation inverters. The proposed presynchronization control method effectively avoids a high transient overcurrent and achieves a seamless grid connection to different types of shore power. The simulation results verify the effectiveness of the proposed control method.\",\"PeriodicalId\":49426,\"journal\":{\"name\":\"Transactions of the Institute of Measurement and Control\",\"volume\":\"9 12\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions of the Institute of Measurement and Control\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1177/01423312231198922\",\"RegionNum\":4,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the Institute of Measurement and Control","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1177/01423312231198922","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
Presynchronization control for ship microgrid of merchant marine inverters based on VSG algorithm with MFAC
The paper studies a presynchronization control of grid connection for large merchant marine microgrid inverters. We present a virtual synchronous generator (VSG) algorithm with model-free adaptive control (MFAC) to optimize the stable grid connection of ship microgrid and shore-to-ship power. To solve poor precision of presynchronization control under nonideal ship microgrid condition, an MFAC controller and its presynchronization method are developed for grid connection of ship-distributed generation inverters. The proposed presynchronization control method effectively avoids a high transient overcurrent and achieves a seamless grid connection to different types of shore power. The simulation results verify the effectiveness of the proposed control method.
期刊介绍:
Transactions of the Institute of Measurement and Control is a fully peer-reviewed international journal. The journal covers all areas of applications in instrumentation and control. Its scope encompasses cutting-edge research and development, education and industrial applications.