{"title":"接受冠状动脉造影术的患者血浆中高含量的内糖蛋白与心血管事件。","authors":"Yoshimi Kishimoto, Emi Saita, Reiko Ohmori, Kazuo Kondo, Yukihiko Momiyama","doi":"10.1007/s00380-023-02353-7","DOIUrl":null,"url":null,"abstract":"<p><p>Endosialin, also known as tumor endothelial marker-1, is a transmembrane glycoprotein that plays a role in inflammation and tumor progression. Endosialin is upregulated in atherosclerotic lesions. To elucidate the association between blood endosialin levels and cardiovascular events, we measured plasma endosialin levels in 389 patients undergoing coronary angiography who were followed up for a mean follow-up of 6.4 ± 4.2 years for cardiovascular events (cardiovascular death, myocardial infarction, unstable angina, heart failure, stroke, or need for coronary revascularization). Of the 389 patients, 223 had coronary artery disease (CAD). No significant difference was found in plasma endosialin levels between patients with and without CAD (median 0.92 vs. 0.92 ng/mL). During the follow-up, cardiovascular events occurred in 62 patients. Compared with patients without events, those with events had higher endosialin levels (1.12 vs. 0.89 ng/mL), and more often had endosialin level of > 1.1 ng/mL (53% vs. 31%) (P < 0.01). A Kaplan-Meier analysis showed lower event-free survival in patients with endosialin > 1.1 ng/mL than those with ≤ 1.1 ng/mL (P < 0.01). In a multivariate Cox regression analysis, endosialin > 1.1 ng/mL was an independent predictor of cardiovascular events (hazard ratio = 2.00; 95%CI = 1.21-3.32; P < 0.01). Thus, high plasma endosialin levels were associated with an increased risk of cardiovascular events in patients undergoing coronary angiography.</p>","PeriodicalId":12940,"journal":{"name":"Heart and Vessels","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High plasma levels of endosialin and cardiovascular events in patients undergoing coronary angiography.\",\"authors\":\"Yoshimi Kishimoto, Emi Saita, Reiko Ohmori, Kazuo Kondo, Yukihiko Momiyama\",\"doi\":\"10.1007/s00380-023-02353-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Endosialin, also known as tumor endothelial marker-1, is a transmembrane glycoprotein that plays a role in inflammation and tumor progression. Endosialin is upregulated in atherosclerotic lesions. To elucidate the association between blood endosialin levels and cardiovascular events, we measured plasma endosialin levels in 389 patients undergoing coronary angiography who were followed up for a mean follow-up of 6.4 ± 4.2 years for cardiovascular events (cardiovascular death, myocardial infarction, unstable angina, heart failure, stroke, or need for coronary revascularization). Of the 389 patients, 223 had coronary artery disease (CAD). No significant difference was found in plasma endosialin levels between patients with and without CAD (median 0.92 vs. 0.92 ng/mL). During the follow-up, cardiovascular events occurred in 62 patients. Compared with patients without events, those with events had higher endosialin levels (1.12 vs. 0.89 ng/mL), and more often had endosialin level of > 1.1 ng/mL (53% vs. 31%) (P < 0.01). A Kaplan-Meier analysis showed lower event-free survival in patients with endosialin > 1.1 ng/mL than those with ≤ 1.1 ng/mL (P < 0.01). In a multivariate Cox regression analysis, endosialin > 1.1 ng/mL was an independent predictor of cardiovascular events (hazard ratio = 2.00; 95%CI = 1.21-3.32; P < 0.01). Thus, high plasma endosialin levels were associated with an increased risk of cardiovascular events in patients undergoing coronary angiography.</p>\",\"PeriodicalId\":12940,\"journal\":{\"name\":\"Heart and Vessels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart and Vessels\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00380-023-02353-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart and Vessels","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00380-023-02353-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
High plasma levels of endosialin and cardiovascular events in patients undergoing coronary angiography.
Endosialin, also known as tumor endothelial marker-1, is a transmembrane glycoprotein that plays a role in inflammation and tumor progression. Endosialin is upregulated in atherosclerotic lesions. To elucidate the association between blood endosialin levels and cardiovascular events, we measured plasma endosialin levels in 389 patients undergoing coronary angiography who were followed up for a mean follow-up of 6.4 ± 4.2 years for cardiovascular events (cardiovascular death, myocardial infarction, unstable angina, heart failure, stroke, or need for coronary revascularization). Of the 389 patients, 223 had coronary artery disease (CAD). No significant difference was found in plasma endosialin levels between patients with and without CAD (median 0.92 vs. 0.92 ng/mL). During the follow-up, cardiovascular events occurred in 62 patients. Compared with patients without events, those with events had higher endosialin levels (1.12 vs. 0.89 ng/mL), and more often had endosialin level of > 1.1 ng/mL (53% vs. 31%) (P < 0.01). A Kaplan-Meier analysis showed lower event-free survival in patients with endosialin > 1.1 ng/mL than those with ≤ 1.1 ng/mL (P < 0.01). In a multivariate Cox regression analysis, endosialin > 1.1 ng/mL was an independent predictor of cardiovascular events (hazard ratio = 2.00; 95%CI = 1.21-3.32; P < 0.01). Thus, high plasma endosialin levels were associated with an increased risk of cardiovascular events in patients undergoing coronary angiography.
期刊介绍:
Heart and Vessels is an English-language journal that provides a forum of original ideas, excellent methods, and fascinating techniques on cardiovascular disease fields. All papers submitted for publication are evaluated only with regard to scientific quality and relevance to the heart and vessels. Contributions from those engaged in practical medicine, as well as from those involved in basic research, are welcomed.