通过开/关开关改造电机控制中心断路器以防止电机故障

Ahmad Rosyiddin, Imam Maulana Arief, Novarino Herdyan Minanta
{"title":"通过开/关开关改造电机控制中心断路器以防止电机故障","authors":"Ahmad Rosyiddin, Imam Maulana Arief, Novarino Herdyan Minanta","doi":"10.22146/jmdt.85643","DOIUrl":null,"url":null,"abstract":"Motor Control Center (MCC) GT module, is a power breaker device that connects the voltage source to the load. MCC breaker rack-in and rack-out activities can be classified as unsafe action and unsade condition.  Because there is a possibility of explosion. As it had happened several times in several places in the world. In 2021 there were 3 force derating and force outages which are caused by MCC motor breaker failures. That accident resulted 500,516.67 KWh loss or Rp 682,262,223,- ($ 44,766). Therefore, modifications need to be made to 0.4kV MCC breaker by adding a selector for the order off blocker to minimize socket damage due to frequent rack-in-rack-out breakers activity. After installing the modification to all breakers in Priok POMU, there was no failures occurred. The frequency of rack-in-rack-out activities were reduced significantly and that is a good result for operation safety. This modification can also prevent Priok POMU from a potential loss and potentially increase net profit up to Rp 221,549,398,- ($ 14,537).","PeriodicalId":201653,"journal":{"name":"Journal of Mechanical Design and Testing","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Motor Control Center Breaker Modification Through On/Off Switch to Prevent Motor Failure\",\"authors\":\"Ahmad Rosyiddin, Imam Maulana Arief, Novarino Herdyan Minanta\",\"doi\":\"10.22146/jmdt.85643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Motor Control Center (MCC) GT module, is a power breaker device that connects the voltage source to the load. MCC breaker rack-in and rack-out activities can be classified as unsafe action and unsade condition.  Because there is a possibility of explosion. As it had happened several times in several places in the world. In 2021 there were 3 force derating and force outages which are caused by MCC motor breaker failures. That accident resulted 500,516.67 KWh loss or Rp 682,262,223,- ($ 44,766). Therefore, modifications need to be made to 0.4kV MCC breaker by adding a selector for the order off blocker to minimize socket damage due to frequent rack-in-rack-out breakers activity. After installing the modification to all breakers in Priok POMU, there was no failures occurred. The frequency of rack-in-rack-out activities were reduced significantly and that is a good result for operation safety. This modification can also prevent Priok POMU from a potential loss and potentially increase net profit up to Rp 221,549,398,- ($ 14,537).\",\"PeriodicalId\":201653,\"journal\":{\"name\":\"Journal of Mechanical Design and Testing\",\"volume\":\"20 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mechanical Design and Testing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22146/jmdt.85643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechanical Design and Testing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/jmdt.85643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电机控制中心(MCC)GT 模块是连接电压源和负载的断路器装置。MCC 断路器的架入和架出活动可分为不安全操作和不安全状态。 因为存在爆炸的可能性。世界上多个地方曾多次发生过此类事故。2021 年,有 3 起因 MCC 电机断路器故障造成的强制降额和强制停电事故。该事故造成 500,516.67 千瓦时的损失或 682,262,223 印尼盾(44,766 美元)。因此,需要对 0.4 千伏多相交流电容器断路器进行改造,增加一个选择器,用于断电闭锁,以尽量减少因断路器频繁跳闸而造成的插座损坏。在普里奥克 POMU 的所有断路器上都安装了选择器后,没有发生任何故障。架空活动的频率明显降低,这对运行安全来说是一个很好的结果。这一改造还可以防止 Priok POMU 遭受潜在损失,并有可能增加净利润,最高可达 221 549 398 印尼盾(14 537 美元)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Motor Control Center Breaker Modification Through On/Off Switch to Prevent Motor Failure
Motor Control Center (MCC) GT module, is a power breaker device that connects the voltage source to the load. MCC breaker rack-in and rack-out activities can be classified as unsafe action and unsade condition.  Because there is a possibility of explosion. As it had happened several times in several places in the world. In 2021 there were 3 force derating and force outages which are caused by MCC motor breaker failures. That accident resulted 500,516.67 KWh loss or Rp 682,262,223,- ($ 44,766). Therefore, modifications need to be made to 0.4kV MCC breaker by adding a selector for the order off blocker to minimize socket damage due to frequent rack-in-rack-out breakers activity. After installing the modification to all breakers in Priok POMU, there was no failures occurred. The frequency of rack-in-rack-out activities were reduced significantly and that is a good result for operation safety. This modification can also prevent Priok POMU from a potential loss and potentially increase net profit up to Rp 221,549,398,- ($ 14,537).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信