为住院病人设计和开发通风气床

IF 1.1 Q3 Engineering
Darshan Karanje, Shivroop Patil, Shivraj Gursal, P. Hatte
{"title":"为住院病人设计和开发通风气床","authors":"Darshan Karanje, Shivroop Patil, Shivraj Gursal, P. Hatte","doi":"10.18186/thermal.1401660","DOIUrl":null,"url":null,"abstract":"Proper ventilation is a critical consideration for the comfort of hospitalized patients. Dry skin, skin rashes, weariness, poor sleep, and other concerns caused by insufficient ventilation can all be avoided with proper ventilation. Air-Ventilated Air Beds are used to supply air to the major parts of the patient’s body. This air bed is constructed in such a way that air is circulated con-tinually throughout the body of the hospitalized patient. It is especially beneficial for people who are bedridden and need to spend a significant amount of time in bed due to illness. Exces-sive heat generated between the bed and the patient is perhaps the common cause of bedsores. Sweating is the leading cause of bedsores. Air ventilation is included in the system to prevent sweating and reduce the incidences of bedsores. Dual compressors, rubber tubes, flow control valves, and anti-decubitus mattresses are among the components used. The rubber tubes are used to ventilate the space between the body of the patient and the upper surface of the air bed. Above the mattress, the rubber tube mesh is positioned. The air is first compressed in two compressors before passing through the distribution manifold and through the meshing. The tubes are altered by drilling holes at certain intervals. The air from the compressor is circulated through the pipes before passing through the openings in the pipes. The unrestricted passage of compressed air via a capillary tube lowers the temperature of the air. The air exhausted through the capillary tubes maintains the patient’s body temperature stable for a while before lowering it. The air is ventilated throughout the bed in this manner. Bedsore can be avoided by reduction of sweat by using the air in close contact with the patient.","PeriodicalId":45841,"journal":{"name":"Journal of Thermal Engineering","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and development of air ventilated air bed for hospitalized patients\",\"authors\":\"Darshan Karanje, Shivroop Patil, Shivraj Gursal, P. Hatte\",\"doi\":\"10.18186/thermal.1401660\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Proper ventilation is a critical consideration for the comfort of hospitalized patients. Dry skin, skin rashes, weariness, poor sleep, and other concerns caused by insufficient ventilation can all be avoided with proper ventilation. Air-Ventilated Air Beds are used to supply air to the major parts of the patient’s body. This air bed is constructed in such a way that air is circulated con-tinually throughout the body of the hospitalized patient. It is especially beneficial for people who are bedridden and need to spend a significant amount of time in bed due to illness. Exces-sive heat generated between the bed and the patient is perhaps the common cause of bedsores. Sweating is the leading cause of bedsores. Air ventilation is included in the system to prevent sweating and reduce the incidences of bedsores. Dual compressors, rubber tubes, flow control valves, and anti-decubitus mattresses are among the components used. The rubber tubes are used to ventilate the space between the body of the patient and the upper surface of the air bed. Above the mattress, the rubber tube mesh is positioned. The air is first compressed in two compressors before passing through the distribution manifold and through the meshing. The tubes are altered by drilling holes at certain intervals. The air from the compressor is circulated through the pipes before passing through the openings in the pipes. The unrestricted passage of compressed air via a capillary tube lowers the temperature of the air. The air exhausted through the capillary tubes maintains the patient’s body temperature stable for a while before lowering it. The air is ventilated throughout the bed in this manner. Bedsore can be avoided by reduction of sweat by using the air in close contact with the patient.\",\"PeriodicalId\":45841,\"journal\":{\"name\":\"Journal of Thermal Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-08-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18186/thermal.1401660\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18186/thermal.1401660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

适当的通风是保证住院病人舒适的关键因素。适当的通风可以避免皮肤干燥、皮疹、倦怠、睡眠不佳以及其他因通风不足引起的问题。通风气床用于向病人身体的主要部位供气。这种空气床的构造可以使空气在住院病人的全身持续循环。它对因病卧床不起、需要长时间躺在床上的人特别有益。床与病人之间产生的过多热量可能是导致褥疮的常见原因。出汗是导致褥疮的主要原因。系统中的空气流通装置可防止出汗,减少褥疮的发生。所使用的组件包括双压缩机、橡胶管、流量控制阀和防褥疮床垫。橡胶管用于对病人身体和气垫床上表面之间的空间进行通风。橡胶管网位于床垫上方。空气首先在两个压缩机中压缩,然后通过分配歧管和网罩。通过在一定间隔上钻孔来改变管子。来自压缩机的空气先在管道中循环,然后再通过管道上的开口。压缩空气不受限制地通过毛细管可降低空气温度。通过毛细管排出的空气可使病人的体温在降低前保持一段时间的稳定。通过这种方式,整个病床的空气都得到了流通。通过使用与病人密切接触的空气,可以减少出汗,从而避免褥疮。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and development of air ventilated air bed for hospitalized patients
Proper ventilation is a critical consideration for the comfort of hospitalized patients. Dry skin, skin rashes, weariness, poor sleep, and other concerns caused by insufficient ventilation can all be avoided with proper ventilation. Air-Ventilated Air Beds are used to supply air to the major parts of the patient’s body. This air bed is constructed in such a way that air is circulated con-tinually throughout the body of the hospitalized patient. It is especially beneficial for people who are bedridden and need to spend a significant amount of time in bed due to illness. Exces-sive heat generated between the bed and the patient is perhaps the common cause of bedsores. Sweating is the leading cause of bedsores. Air ventilation is included in the system to prevent sweating and reduce the incidences of bedsores. Dual compressors, rubber tubes, flow control valves, and anti-decubitus mattresses are among the components used. The rubber tubes are used to ventilate the space between the body of the patient and the upper surface of the air bed. Above the mattress, the rubber tube mesh is positioned. The air is first compressed in two compressors before passing through the distribution manifold and through the meshing. The tubes are altered by drilling holes at certain intervals. The air from the compressor is circulated through the pipes before passing through the openings in the pipes. The unrestricted passage of compressed air via a capillary tube lowers the temperature of the air. The air exhausted through the capillary tubes maintains the patient’s body temperature stable for a while before lowering it. The air is ventilated throughout the bed in this manner. Bedsore can be avoided by reduction of sweat by using the air in close contact with the patient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.40
自引率
18.20%
发文量
61
审稿时长
4 weeks
期刊介绍: Journal of Thermal Enginering is aimed at giving a recognized platform to students, researchers, research scholars, teachers, authors and other professionals in the field of research in Thermal Engineering subjects, to publish their original and current research work to a wide, international audience. In order to achieve this goal, we will have applied for SCI-Expanded Index in 2021 after having an Impact Factor in 2020. The aim of the journal, published on behalf of Yildiz Technical University in Istanbul-Turkey, is to not only include actual, original and applied studies prepared on the sciences of heat transfer and thermodynamics, and contribute to the literature of engineering sciences on the national and international areas but also help the development of Mechanical Engineering. Engineers and academicians from disciplines of Power Plant Engineering, Energy Engineering, Building Services Engineering, HVAC Engineering, Solar Engineering, Wind Engineering, Nanoengineering, surface engineering, thin film technologies, and Computer Aided Engineering will be expected to benefit from this journal’s outputs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信