利用酶联免疫吸附试验(ELISA)测量血清中抗酚类糖脂-1的IgM和IgG水平及其准确性,用于早期检测麻风分枝杆菌:一个实验室的现实

Salsabilla Putri, Kinanti Abdullah, D. Adriaty, Puput Ade Wahyuningtyas, L. Yamani, M. Alinda, Ratna Wahyuni, Cita Rosita, Sigit Prakoeswa
{"title":"利用酶联免疫吸附试验(ELISA)测量血清中抗酚类糖脂-1的IgM和IgG水平及其准确性,用于早期检测麻风分枝杆菌:一个实验室的现实","authors":"Salsabilla Putri, Kinanti Abdullah, D. Adriaty, Puput Ade Wahyuningtyas, L. Yamani, M. Alinda, Ratna Wahyuni, Cita Rosita, Sigit Prakoeswa","doi":"10.20473/ijtid.v11i2.43481","DOIUrl":null,"url":null,"abstract":"Indonesia was the third most recent case of leprosy globally in 2020 with 11,173 people, after India and Brazil. Most of the leprosy manifestations are asymptomatic. This is possibly as subclinical leprosy which individuals without leprosy symptoms but have leprosy specific antibodies high levels, so it has the potential to become a transmission and disability. Therefore, an ELISA test need for early detection in preventing leprosy transmission. This study aims to measure IgM and IgG antibody levels in leprosy patients and assess the accuracy of the measurement results. This research is a cross-sectional study. Five patients' blood samples have analyzed for IgM and IgG anti-PGL-1 antibody levels by ELISA. Accuracy interpretation of this measurement based on the %CV. Antibody levels were classified based on the cut-off <605 u/ml as IgM seronegative or <630 u/ml as IgG seronegative, 605–1000 u/ml as low seropositive IgM or 630-1000 u/ml as low seropositive IgG, and >1000 u/ml as high seropositive IgM and IgG. Among five patients examined, 40% had high seropositive leprosy with anti-PGL-1 IgM and IgG antibody titers>1000 u/ml, and 60% of patients had seronegative leprosy. Accuracy in this ELISA test shows high accuracy with %CV <10% in the conversion of OD to antibody titer levels.  IgM and IgG Anti PGL-1 antibody titers by ELISA as one of the parameters in identifying patients at higher risk of leprosy. A significant portion of patients with high seropositive leprosy with high accuracy.","PeriodicalId":13538,"journal":{"name":"Indonesian Journal of Tropical and Infectious Disease","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurements and Accuracy of IgM and IgG Anti Phenolic Glycolipid-1 Levels in Blood Serum for Early Detection Mycobacterium leprae by using Enzyme-Linked Immunosorbent Assay (ELISA): A Reality of a Laboratory\",\"authors\":\"Salsabilla Putri, Kinanti Abdullah, D. Adriaty, Puput Ade Wahyuningtyas, L. Yamani, M. Alinda, Ratna Wahyuni, Cita Rosita, Sigit Prakoeswa\",\"doi\":\"10.20473/ijtid.v11i2.43481\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Indonesia was the third most recent case of leprosy globally in 2020 with 11,173 people, after India and Brazil. Most of the leprosy manifestations are asymptomatic. This is possibly as subclinical leprosy which individuals without leprosy symptoms but have leprosy specific antibodies high levels, so it has the potential to become a transmission and disability. Therefore, an ELISA test need for early detection in preventing leprosy transmission. This study aims to measure IgM and IgG antibody levels in leprosy patients and assess the accuracy of the measurement results. This research is a cross-sectional study. Five patients' blood samples have analyzed for IgM and IgG anti-PGL-1 antibody levels by ELISA. Accuracy interpretation of this measurement based on the %CV. Antibody levels were classified based on the cut-off <605 u/ml as IgM seronegative or <630 u/ml as IgG seronegative, 605–1000 u/ml as low seropositive IgM or 630-1000 u/ml as low seropositive IgG, and >1000 u/ml as high seropositive IgM and IgG. Among five patients examined, 40% had high seropositive leprosy with anti-PGL-1 IgM and IgG antibody titers>1000 u/ml, and 60% of patients had seronegative leprosy. Accuracy in this ELISA test shows high accuracy with %CV <10% in the conversion of OD to antibody titer levels.  IgM and IgG Anti PGL-1 antibody titers by ELISA as one of the parameters in identifying patients at higher risk of leprosy. A significant portion of patients with high seropositive leprosy with high accuracy.\",\"PeriodicalId\":13538,\"journal\":{\"name\":\"Indonesian Journal of Tropical and Infectious Disease\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Tropical and Infectious Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20473/ijtid.v11i2.43481\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Tropical and Infectious Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/ijtid.v11i2.43481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

2020 年,印度尼西亚的麻风病例为 11 173 例,位居全球第三,仅次于印度和巴西。大多数麻风病表现为无症状。这可能是亚临床麻风病,即没有麻风病症状但麻风病特异性抗体水平较高的人,因此有可能传播麻风病并致残。因此,需要用 ELISA 检测法进行早期检测,以预防麻风病的传播。本研究旨在测量麻风病人的 IgM 和 IgG 抗体水平,并评估测量结果的准确性。本研究为横断面研究。五名患者的血液样本通过 ELISA 方法分析了 IgM 和 IgG 抗PGL-1 抗体水平。测量结果的准确性以 %CV 为基础。抗体水平以 1000 u/ml 为临界值,分为高血清阳性 IgM 和 IgG。在接受检查的五名患者中,40%为抗-PGL-1 IgM和IgG抗体滴度>1000 u/ml的高血清阳性麻风病人,60%为血清阴性麻风病人。该酶联免疫吸附试验的准确性很高,将OD值转换为抗体滴度水平的%CV小于10%。 用 ELISA 检测 IgM 和 IgG 抗 PGL-1 抗体滴度是识别麻风病高危患者的参数之一。相当一部分高血清阳性麻风病人的准确率很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurements and Accuracy of IgM and IgG Anti Phenolic Glycolipid-1 Levels in Blood Serum for Early Detection Mycobacterium leprae by using Enzyme-Linked Immunosorbent Assay (ELISA): A Reality of a Laboratory
Indonesia was the third most recent case of leprosy globally in 2020 with 11,173 people, after India and Brazil. Most of the leprosy manifestations are asymptomatic. This is possibly as subclinical leprosy which individuals without leprosy symptoms but have leprosy specific antibodies high levels, so it has the potential to become a transmission and disability. Therefore, an ELISA test need for early detection in preventing leprosy transmission. This study aims to measure IgM and IgG antibody levels in leprosy patients and assess the accuracy of the measurement results. This research is a cross-sectional study. Five patients' blood samples have analyzed for IgM and IgG anti-PGL-1 antibody levels by ELISA. Accuracy interpretation of this measurement based on the %CV. Antibody levels were classified based on the cut-off <605 u/ml as IgM seronegative or <630 u/ml as IgG seronegative, 605–1000 u/ml as low seropositive IgM or 630-1000 u/ml as low seropositive IgG, and >1000 u/ml as high seropositive IgM and IgG. Among five patients examined, 40% had high seropositive leprosy with anti-PGL-1 IgM and IgG antibody titers>1000 u/ml, and 60% of patients had seronegative leprosy. Accuracy in this ELISA test shows high accuracy with %CV <10% in the conversion of OD to antibody titer levels.  IgM and IgG Anti PGL-1 antibody titers by ELISA as one of the parameters in identifying patients at higher risk of leprosy. A significant portion of patients with high seropositive leprosy with high accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
8
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信