Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin
{"title":"一次性铜/硫酸铜参比电极在钢筋混凝土腐蚀分析中的性能","authors":"Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin","doi":"10.17576/jsm-2023-5209-18","DOIUrl":null,"url":null,"abstract":"The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.","PeriodicalId":21366,"journal":{"name":"Sains Malaysiana","volume":"56 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of Disposable Cu/CuSO4 Reference Electrode in Reinforced Concrete Corrosion Analysis\",\"authors\":\"Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin\",\"doi\":\"10.17576/jsm-2023-5209-18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.\",\"PeriodicalId\":21366,\"journal\":{\"name\":\"Sains Malaysiana\",\"volume\":\"56 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sains Malaysiana\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.17576/jsm-2023-5209-18\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sains Malaysiana","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.17576/jsm-2023-5209-18","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
Performance of Disposable Cu/CuSO4 Reference Electrode in Reinforced Concrete Corrosion Analysis
The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.
期刊介绍:
Sains Malaysiana is a refereed journal committed to the advancement of scholarly knowledge and research findings of the several branches of science and technology. It contains articles on Earth Sciences, Health Sciences, Life Sciences, Mathematical Sciences and Physical Sciences. The journal publishes articles, reviews, and research notes whose content and approach are of interest to a wide range of scholars. Sains Malaysiana is published by the UKM Press an its autonomous Editorial Board are drawn from the Faculty of Science and Technology, Universiti Kebangsaan Malaysia. In addition, distinguished scholars from local and foreign universities are appointed to serve as advisory board members and referees.