一次性铜/硫酸铜参比电极在钢筋混凝土腐蚀分析中的性能

IF 0.7 4区 综合性期刊 Q3 MULTIDISCIPLINARY SCIENCES
Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin
{"title":"一次性铜/硫酸铜参比电极在钢筋混凝土腐蚀分析中的性能","authors":"Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin","doi":"10.17576/jsm-2023-5209-18","DOIUrl":null,"url":null,"abstract":"The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.","PeriodicalId":21366,"journal":{"name":"Sains Malaysiana","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of Disposable Cu/CuSO4 Reference Electrode in Reinforced Concrete Corrosion Analysis\",\"authors\":\"Muhammad Ihsan, S. Fonna, S. Huzni, Nurul Islami, Sagir Alva, Ahmad Kamal Ariffin\",\"doi\":\"10.17576/jsm-2023-5209-18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.\",\"PeriodicalId\":21366,\"journal\":{\"name\":\"Sains Malaysiana\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sains Malaysiana\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.17576/jsm-2023-5209-18\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sains Malaysiana","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.17576/jsm-2023-5209-18","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

过去十年中,对腐蚀分析参比电极性能的研究得到了广泛开展。腐蚀研究的一个特殊需求是需要一种一次性且可靠的参比电极。本研究调查了液基和固态参比电极的有效性,这两种电极均可一次性使用,且性能可靠。电极是在硫酸铜-铜(CCS)液基和固态电极内用低成本材料制备的(一次性使用)。通过测量钢筋混凝土试样的开路电位 (OCP),测试了电位稳定性的可靠性。研究了固态参比电极和液态参比电极在腐蚀环境中的极化行为。此外,还获得了实时电位数据,用于腐蚀率调查。结果表明,在腐蚀测量过程中,(OCP)值具有一致性。从最大电位值到最小电位值的偏差小于 0.02 V,验证了液态铜(Cu)电极和固态铜(Cu)电极在钢筋混凝土腐蚀测量中的可靠性、适应性和一次性。在钢筋锈蚀电位测量方面,实时极化测量结果表明,高风险锈蚀发生在预埋钢筋上,并通过直接观察钢筋混凝土试件得到了验证。因此,我们可以得出结论,这两种参比电极的一次性使用显示了其稳定性,并大大降低了钢筋混凝土腐蚀研究的成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance of Disposable Cu/CuSO4 Reference Electrode in Reinforced Concrete Corrosion Analysis
The investigation of reference electrode performance for corrosion analysis has been widely conducted over the last decade. The need for a disposable and reliable reference electrode is a specific need for corrosion investigation. This research investigated the effectiveness of liquid-based and solid-state reference electrodes, which are disposable and provide reliable performance. The electrode was prepared with low-cost material preparation (disposable usage) within a Copper-Copper Sulphate (CCS) liquid-based and solid-state electrodes. The potential stability was already tested for dependability by measuring the Open Circuit Potential (OCP) on the rebar concrete specimen. The behaviour of solid-state reference and liquid-based reference electrodes in terms of polarization was studied in a corroded environment. Real-time potential data was also obtained for the corrosion rate investigation. The result shows the consistency performance of (OCP) value during corrosion measurement. The deviation of the maximum to a minimum potential value less than 0.02 V, verifies that the liquid-based copper (Cu) electrode and solid-state copper (Cu) electrodes are reliable, adaptable, and disposable for reinforced concrete corrosion measurement. In terms of corroded rebar potential measurement, the real-time polarization measurement result shows that the high-risk corroding occurred on the embedded rebar and was validated by directly visualizing the rebar concrete specimen. Therefore, the results obtained allow us to conclude that the disposable of both reference electrodes shows their stability and significantly reduces the reinforced concrete corrosion research cost.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sains Malaysiana
Sains Malaysiana MULTIDISCIPLINARY SCIENCES-
CiteScore
1.60
自引率
12.50%
发文量
196
审稿时长
3-6 weeks
期刊介绍: Sains Malaysiana is a refereed journal committed to the advancement of scholarly knowledge and research findings of the several branches of science and technology. It contains articles on Earth Sciences, Health Sciences, Life Sciences, Mathematical Sciences and Physical Sciences. The journal publishes articles, reviews, and research notes whose content and approach are of interest to a wide range of scholars. Sains Malaysiana is published by the UKM Press an its autonomous Editorial Board are drawn from the Faculty of Science and Technology, Universiti Kebangsaan Malaysia. In addition, distinguished scholars from local and foreign universities are appointed to serve as advisory board members and referees.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信