环境空气中微粒物质 2.5 浓度分析和巴东市乌鲁加杜特乌南德住宅区 B 的 PM2.5 减排工厂建议

Yega Serlina, Vera Surtia Bachtiar, I. Putra
{"title":"环境空气中微粒物质 2.5 浓度分析和巴东市乌鲁加杜特乌南德住宅区 B 的 PM2.5 减排工厂建议","authors":"Yega Serlina, Vera Surtia Bachtiar, I. Putra","doi":"10.32672/jse.v8i4.6863","DOIUrl":null,"url":null,"abstract":"This research aims to analyze the concentration of Particulate Matter 2.5 (PM 2.5 ) around PT Semen Padang and recommendations for planting PM 2.5 reducing plants in Unand Housing Block B, Ulu Gadut, Padang City. Sampling was carried out with EPAM-5000 HAZ-DUST and LVAS 4 times over 24 hours at 4 sampling point locations. The PM 2.5 measurement results using the EPAM-5000 were in the range 37,875– 45.50 μg/m 3 while using LVAS were in the range 38,127–45,745 μg/m 3 . Based on the t-test, there is no significant difference in the results of measuring PM 2.5 using both tools with p-value > 0.05. The highest concentration of PM 2.5 was at the Dian Andalas School area. PM 2.5 concentration is below the quality standard according to PP RI Number 22 of 2021. Correlation analysis of PM 2.5 concentration with meteorological conditions shows a inverse relationship, with negative correlation coefficient value in the range (-0.90481)-(-0.93514) which is shows that the relationship is very strong. The results of a questionnaire to identify public health effects showed 27% of people had respiratory diseases such as asthma, throat irritation, headaches, and others. The recommended plant selected in this research is the Cemara Kipas with ecological criteria evaluation results of 66.7%.","PeriodicalId":17758,"journal":{"name":"Jurnal Serambi Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisis Konsentrasi Particulate Matter 2,5 di Udara Ambien dan Rekomendasi Tanaman Pereduksi PM2,5 di Perumahan Unand Blok B, Ulu Gadut, Kota Padang\",\"authors\":\"Yega Serlina, Vera Surtia Bachtiar, I. Putra\",\"doi\":\"10.32672/jse.v8i4.6863\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research aims to analyze the concentration of Particulate Matter 2.5 (PM 2.5 ) around PT Semen Padang and recommendations for planting PM 2.5 reducing plants in Unand Housing Block B, Ulu Gadut, Padang City. Sampling was carried out with EPAM-5000 HAZ-DUST and LVAS 4 times over 24 hours at 4 sampling point locations. The PM 2.5 measurement results using the EPAM-5000 were in the range 37,875– 45.50 μg/m 3 while using LVAS were in the range 38,127–45,745 μg/m 3 . Based on the t-test, there is no significant difference in the results of measuring PM 2.5 using both tools with p-value > 0.05. The highest concentration of PM 2.5 was at the Dian Andalas School area. PM 2.5 concentration is below the quality standard according to PP RI Number 22 of 2021. Correlation analysis of PM 2.5 concentration with meteorological conditions shows a inverse relationship, with negative correlation coefficient value in the range (-0.90481)-(-0.93514) which is shows that the relationship is very strong. The results of a questionnaire to identify public health effects showed 27% of people had respiratory diseases such as asthma, throat irritation, headaches, and others. The recommended plant selected in this research is the Cemara Kipas with ecological criteria evaluation results of 66.7%.\",\"PeriodicalId\":17758,\"journal\":{\"name\":\"Jurnal Serambi Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Serambi Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32672/jse.v8i4.6863\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Serambi Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32672/jse.v8i4.6863","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在分析 PT Semen Padang 附近的颗粒物 2.5(PM2.5)浓度,并提出在巴东市乌鲁加杜特的乌南德住宅区 B 区种植可减少 PM2.5 的植物的建议。使用 EPAM-5000 HAZ-DUST 和 LVAS 在 4 个采样点进行了 4 次采样,每次 24 小时。使用 EPAM-5000 测量 PM 2.5 的结果范围为 37,875-45,50 μg/m 3,而使用 LVAS 测量 PM 2.5 的结果范围为 38,127-45,745 μg/m 3。根据 t 检验,使用这两种工具测量 PM 2.5 的结果没有显著差异,p 值大于 0.05。Dian Andalas 学校区域的 PM 2.5 浓度最高。根据 2021 年第 22 号 PP RI,PM 2.5 浓度低于质量标准。PM 2.5 浓度与气象条件的相关性分析表明两者呈反向关系,负相关系数值在 (-0.90481)-(-0.93514) 之间,表明两者关系非常密切。对公众健康影响的问卷调查结果显示,27% 的人患有呼吸道疾病,如哮喘、喉咙不适、头痛等。本研究选择的推荐植物是 Cemara Kipas,其生态标准评估结果为 66.7%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analisis Konsentrasi Particulate Matter 2,5 di Udara Ambien dan Rekomendasi Tanaman Pereduksi PM2,5 di Perumahan Unand Blok B, Ulu Gadut, Kota Padang
This research aims to analyze the concentration of Particulate Matter 2.5 (PM 2.5 ) around PT Semen Padang and recommendations for planting PM 2.5 reducing plants in Unand Housing Block B, Ulu Gadut, Padang City. Sampling was carried out with EPAM-5000 HAZ-DUST and LVAS 4 times over 24 hours at 4 sampling point locations. The PM 2.5 measurement results using the EPAM-5000 were in the range 37,875– 45.50 μg/m 3 while using LVAS were in the range 38,127–45,745 μg/m 3 . Based on the t-test, there is no significant difference in the results of measuring PM 2.5 using both tools with p-value > 0.05. The highest concentration of PM 2.5 was at the Dian Andalas School area. PM 2.5 concentration is below the quality standard according to PP RI Number 22 of 2021. Correlation analysis of PM 2.5 concentration with meteorological conditions shows a inverse relationship, with negative correlation coefficient value in the range (-0.90481)-(-0.93514) which is shows that the relationship is very strong. The results of a questionnaire to identify public health effects showed 27% of people had respiratory diseases such as asthma, throat irritation, headaches, and others. The recommended plant selected in this research is the Cemara Kipas with ecological criteria evaluation results of 66.7%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信