对可重复使用的 2 级隔离服在延长使用寿命期间的阻隔性和耐久性能进行评估

Elizabeth Easter, Susan Dabbain
{"title":"对可重复使用的 2 级隔离服在延长使用寿命期间的阻隔性和耐久性能进行评估","authors":"Elizabeth Easter, Susan Dabbain","doi":"10.1177/24723444231212950","DOIUrl":null,"url":null,"abstract":"The COVID-19 pandemic negatively impacted the health and safety of healthcare workers as the supply of personal protective equipment was severely limited at the pandemic’s beginning. Some healthcare facilities took the Centers for Disease Control and Prevention’s recommendations to shift from disposable personal protective equipment to reusable, as an option for extending the life of their personal protective equipment during the pandemic. This research investigated Level 2 isolation gowns to determine whether they met or exceeded the protection specifications of ANSI/AAMI PB70:2012 and the American Society for Testing and Materials: ASTM F3352-19 Standard Specification for Isolation Gowns Intended for Use in Healthcare Facilities. The overall findings show that commercially available reusable gowns initially met the ANSI/AAMI PB70:2012 and ASTM F3352 standards. Out of the six sample groups, gowns in one group failed the ANSI/AAMI PB70:2012 specifications before the end of their intended lifecycle. All gowns met the specifications for durability in ASTM F3352-19, but further research showed tear strength after laundering weakened substantially. The current standard for Level 2 isolation gowns is protecting the lives of healthcare workers. However, the specifications could be improved by ANSI/AAMI by evaluating the performance after laundering instead of as new. Durability specifications would be improved by increasing the requirements for reusable gowns.","PeriodicalId":502144,"journal":{"name":"AATCC Journal of Research","volume":"4 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Evaluation of the Barrier and Durability Performance of Reusable Level 2 Isolation Gowns Over Their Promoted Service Life\",\"authors\":\"Elizabeth Easter, Susan Dabbain\",\"doi\":\"10.1177/24723444231212950\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The COVID-19 pandemic negatively impacted the health and safety of healthcare workers as the supply of personal protective equipment was severely limited at the pandemic’s beginning. Some healthcare facilities took the Centers for Disease Control and Prevention’s recommendations to shift from disposable personal protective equipment to reusable, as an option for extending the life of their personal protective equipment during the pandemic. This research investigated Level 2 isolation gowns to determine whether they met or exceeded the protection specifications of ANSI/AAMI PB70:2012 and the American Society for Testing and Materials: ASTM F3352-19 Standard Specification for Isolation Gowns Intended for Use in Healthcare Facilities. The overall findings show that commercially available reusable gowns initially met the ANSI/AAMI PB70:2012 and ASTM F3352 standards. Out of the six sample groups, gowns in one group failed the ANSI/AAMI PB70:2012 specifications before the end of their intended lifecycle. All gowns met the specifications for durability in ASTM F3352-19, but further research showed tear strength after laundering weakened substantially. The current standard for Level 2 isolation gowns is protecting the lives of healthcare workers. However, the specifications could be improved by ANSI/AAMI by evaluating the performance after laundering instead of as new. Durability specifications would be improved by increasing the requirements for reusable gowns.\",\"PeriodicalId\":502144,\"journal\":{\"name\":\"AATCC Journal of Research\",\"volume\":\"4 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AATCC Journal of Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/24723444231212950\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AATCC Journal of Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/24723444231212950","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

COVID-19 大流行对医护人员的健康和安全造成了负面影响,因为在大流行开始时,个人防护设备的供应严重受限。一些医疗机构采纳了美国疾病控制和预防中心的建议,将一次性个人防护设备改为可重复使用,以此作为在大流行期间延长个人防护设备使用寿命的一种选择。这项研究对 2 级隔离衣进行了调查,以确定它们是否达到或超过 ANSI/AAMI PB70:2012 和美国材料与试验协会的防护规范:ASTM F3352-19 医疗机构隔离衣标准规范》。总体结果表明,市售可重复使用隔离衣初步达到了 ANSI/AAMI PB70:2012 和 ASTM F3352 标准。在六组样本中,有一组的隔离衣在预定生命周期结束前未能达到 ANSI/AAMI PB70:2012 的规格要求。所有隔离衣均符合 ASTM F3352-19 的耐用性规范,但进一步的研究表明,洗涤后的撕裂强度大大减弱。二级隔离衣的现行标准保护了医护人员的生命安全。不过,ANSI/AAMI 可以通过评估洗涤后的性能而不是全新的性能来改进规格。通过提高对可重复使用隔离衣的要求,可改进耐用性规格。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Evaluation of the Barrier and Durability Performance of Reusable Level 2 Isolation Gowns Over Their Promoted Service Life
The COVID-19 pandemic negatively impacted the health and safety of healthcare workers as the supply of personal protective equipment was severely limited at the pandemic’s beginning. Some healthcare facilities took the Centers for Disease Control and Prevention’s recommendations to shift from disposable personal protective equipment to reusable, as an option for extending the life of their personal protective equipment during the pandemic. This research investigated Level 2 isolation gowns to determine whether they met or exceeded the protection specifications of ANSI/AAMI PB70:2012 and the American Society for Testing and Materials: ASTM F3352-19 Standard Specification for Isolation Gowns Intended for Use in Healthcare Facilities. The overall findings show that commercially available reusable gowns initially met the ANSI/AAMI PB70:2012 and ASTM F3352 standards. Out of the six sample groups, gowns in one group failed the ANSI/AAMI PB70:2012 specifications before the end of their intended lifecycle. All gowns met the specifications for durability in ASTM F3352-19, but further research showed tear strength after laundering weakened substantially. The current standard for Level 2 isolation gowns is protecting the lives of healthcare workers. However, the specifications could be improved by ANSI/AAMI by evaluating the performance after laundering instead of as new. Durability specifications would be improved by increasing the requirements for reusable gowns.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信