隐形眼镜检测:由专家对尺寸稳定的隐形眼镜进行验证和检查

Frank Spors, Donald Egan, Dorcas Tsang, An Vo, Joseph Gray, Sylvia Wulf
{"title":"隐形眼镜检测:由专家对尺寸稳定的隐形眼镜进行验证和检查","authors":"Frank Spors, Donald Egan, Dorcas Tsang, An Vo, Joseph Gray, Sylvia Wulf","doi":"10.54352/dozv.ifyc5218","DOIUrl":null,"url":null,"abstract":"Purpose. The primary focus of this article is to explore the critical aspects of verifying and inspecting RGP contact lens parameters in clinical practice. The verification process is essential to ensure that patients receive lenses with accurate and optimal parameters, thus improving their visual experi- ence and comfort. The article delves into the methods and instruments available to eye care practitioners for verifying key parameters, including back surface radii, total lens diam- eter, lens power, lens thickness, blends, and surface quality. Material and Methods. The discussion centers on the tech- niques and tools employed in the verification and inspection of RGP contact lens parameters. It emphasizes the signifi- cance of maintaining a clean and controlled environment for these assessments. Calibration and error minimization strate- gies are highlighted to enhance measurement accuracy. The article provides insights into device-specific measurements and the importance of averaging measurements to mitigate deviations. Results. The article outlines various procedures for verifying the essential parameters of RGP contact lenses. It covers methods for checking back surface radii, including the use of radiuscopes, keratometers, and corneal topographers. Verifi- cation of lens diameter is detailed with V-shaped measuring gauges, measuring magnifiers, and projection magnifiers. Lens power verification is explored through lensmeters and specialized lensmeter calibration techniques. Finally, the measurement of lens thickness, the inspection of lens edges, and the evaluation of surface quality and blends between different lens zones are addressed. Conclusion. This article underscores the significance of thorough verification and inspection of RGP contact lens parameters in clinical practice. These essential steps ensure that patients receive lenses that meet their specific needs, contributing to improved visual acuity, comfort, and overall ocular health. Eye care practitioners should check their pa- tients’ RGP contact lenses according to the ordered param- eters. By following the described methods and employing appropriate instruments, the fitting and prescribing of rigid gas-permeable contact lenses can be enhanced. Keywords Rigid gas-permeable contact lenses, RGP contact lenses, specifications and tolerances for rigid contact lens parameters, verification and inspection of RGP contact lenses, lens checking","PeriodicalId":347784,"journal":{"name":"Optometry & Contact Lenses","volume":"191 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Kontaktlinsenprüfung: Verifikation und Inspektion formstabiler Kontaktlinsen durch den Spezialisten\",\"authors\":\"Frank Spors, Donald Egan, Dorcas Tsang, An Vo, Joseph Gray, Sylvia Wulf\",\"doi\":\"10.54352/dozv.ifyc5218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. The primary focus of this article is to explore the critical aspects of verifying and inspecting RGP contact lens parameters in clinical practice. The verification process is essential to ensure that patients receive lenses with accurate and optimal parameters, thus improving their visual experi- ence and comfort. The article delves into the methods and instruments available to eye care practitioners for verifying key parameters, including back surface radii, total lens diam- eter, lens power, lens thickness, blends, and surface quality. Material and Methods. The discussion centers on the tech- niques and tools employed in the verification and inspection of RGP contact lens parameters. It emphasizes the signifi- cance of maintaining a clean and controlled environment for these assessments. Calibration and error minimization strate- gies are highlighted to enhance measurement accuracy. The article provides insights into device-specific measurements and the importance of averaging measurements to mitigate deviations. Results. The article outlines various procedures for verifying the essential parameters of RGP contact lenses. It covers methods for checking back surface radii, including the use of radiuscopes, keratometers, and corneal topographers. Verifi- cation of lens diameter is detailed with V-shaped measuring gauges, measuring magnifiers, and projection magnifiers. Lens power verification is explored through lensmeters and specialized lensmeter calibration techniques. Finally, the measurement of lens thickness, the inspection of lens edges, and the evaluation of surface quality and blends between different lens zones are addressed. Conclusion. This article underscores the significance of thorough verification and inspection of RGP contact lens parameters in clinical practice. These essential steps ensure that patients receive lenses that meet their specific needs, contributing to improved visual acuity, comfort, and overall ocular health. Eye care practitioners should check their pa- tients’ RGP contact lenses according to the ordered param- eters. By following the described methods and employing appropriate instruments, the fitting and prescribing of rigid gas-permeable contact lenses can be enhanced. Keywords Rigid gas-permeable contact lenses, RGP contact lenses, specifications and tolerances for rigid contact lens parameters, verification and inspection of RGP contact lenses, lens checking\",\"PeriodicalId\":347784,\"journal\":{\"name\":\"Optometry & Contact Lenses\",\"volume\":\"191 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optometry & Contact Lenses\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54352/dozv.ifyc5218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry & Contact Lenses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54352/dozv.ifyc5218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的。本文的主要重点是探讨在临床实践中验证和检查 RGP 隐形眼镜参数的关键环节。验证过程对于确保患者配戴的镜片具有准确和最佳参数,从而改善他们的视觉体验和舒适度至关重要。文章深入探讨了眼科护理从业人员可用来验证关键参数的方法和仪器,包括镜片后表面半径、镜片总直径、镜片功率、镜片厚度、混合度和表面质量。材料和方法。讨论的中心是用于验证和检查 RGP 隐形眼镜参数的技术和工具。它强调了在这些评估中保持清洁和受控环境的重要性。文章强调了校准和误差最小化策略,以提高测量的准确性。文章深入介绍了特定设备的测量方法,以及平均测量以减少偏差的重要性。结果。文章概述了验证 RGP 隐形眼镜基本参数的各种程序。文章介绍了检查镜片背面半径的方法,包括使用半径计、角膜计和角膜地形图仪。详细介绍了使用 V 形测量仪、测量放大镜和投影放大镜验证镜片直径的方法。通过镜片测量仪和专门的镜片测量仪校准技术来探讨镜片功率的验证。最后,还讨论了镜片厚度的测量、镜片边缘的检查、表面质量的评估以及不同镜片区域之间的混合。结论。本文强调了在临床实践中彻底验证和检查 RGP 隐形眼镜参数的重要性。这些基本步骤可确保患者获得满足其特定需求的镜片,有助于提高视力、舒适度和整体眼部健康。眼科护理从业人员应根据订购的参数检查患者的 RGP 隐形眼镜。按照所述方法并使用适当的仪器,可以提高硬性透气接触镜的验配和处方水平。关键词 硬性透气接触镜、RGP 接触镜、硬性接触镜参数的规格和公差、RGP 接触镜的验证和检查、镜片检查
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Kontaktlinsenprüfung: Verifikation und Inspektion formstabiler Kontaktlinsen durch den Spezialisten
Purpose. The primary focus of this article is to explore the critical aspects of verifying and inspecting RGP contact lens parameters in clinical practice. The verification process is essential to ensure that patients receive lenses with accurate and optimal parameters, thus improving their visual experi- ence and comfort. The article delves into the methods and instruments available to eye care practitioners for verifying key parameters, including back surface radii, total lens diam- eter, lens power, lens thickness, blends, and surface quality. Material and Methods. The discussion centers on the tech- niques and tools employed in the verification and inspection of RGP contact lens parameters. It emphasizes the signifi- cance of maintaining a clean and controlled environment for these assessments. Calibration and error minimization strate- gies are highlighted to enhance measurement accuracy. The article provides insights into device-specific measurements and the importance of averaging measurements to mitigate deviations. Results. The article outlines various procedures for verifying the essential parameters of RGP contact lenses. It covers methods for checking back surface radii, including the use of radiuscopes, keratometers, and corneal topographers. Verifi- cation of lens diameter is detailed with V-shaped measuring gauges, measuring magnifiers, and projection magnifiers. Lens power verification is explored through lensmeters and specialized lensmeter calibration techniques. Finally, the measurement of lens thickness, the inspection of lens edges, and the evaluation of surface quality and blends between different lens zones are addressed. Conclusion. This article underscores the significance of thorough verification and inspection of RGP contact lens parameters in clinical practice. These essential steps ensure that patients receive lenses that meet their specific needs, contributing to improved visual acuity, comfort, and overall ocular health. Eye care practitioners should check their pa- tients’ RGP contact lenses according to the ordered param- eters. By following the described methods and employing appropriate instruments, the fitting and prescribing of rigid gas-permeable contact lenses can be enhanced. Keywords Rigid gas-permeable contact lenses, RGP contact lenses, specifications and tolerances for rigid contact lens parameters, verification and inspection of RGP contact lenses, lens checking
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信