提高环保效率的供暖锅炉的运行问题

Q3 Engineering
N. Fialko, R. Navrodska, S. Shevchuk, R. V. Serhiienko
{"title":"提高环保效率的供暖锅炉的运行问题","authors":"N. Fialko, R. Navrodska, S. Shevchuk, R. V. Serhiienko","doi":"10.33271/nvngu/2023-6/054","DOIUrl":null,"url":null,"abstract":"Purpose. Ensuring reliable operation of heating heat-generating devices with recirculation and exhaust gas heat recovery. Methodology. The normative methods of thermal calculation for surface heat exchange devices and the software according to the requirements of regulatory methods for this type of equipment for processing the results of our own experimental studies on heat exchange during deep cooling of combustion products of gas-consuming boilers were used. Findings. Calculation studies on the thermal operation modes during the heating period under the conditions of recirculation and heat recovery of flue gases of gas-fired water-heating boiler plants not equipped with air heaters were carried out. The main characteristics were determined of the thermal and humidity operation state for the air-supply ducts of these installations under the conditions of recirculation of flue gases’ part into the blown air. Regularities of temperature and dew point changes in the mixture of admixed gases and air under the conditions of using traditional heat recovery technologies and without them in different boiler modes and with different parts of recirculated gases were established. Problems of ensuring the operability and reliability of such boiler plants are highlighted. It is shown that these problems are related to condensate formation on the internal surfaces of air ducts and their freezing in some operating modes during in the cold period of the heating season. It is also shown that an effective solution to existing problems can be the use of air heaters in heat recovery systems to preheat the blown air before its mixing with recirculation gases. Originality. For the first time, the thermal and humidity operation modes of the air-supply ducts of heating boiler plants with increased environmental efficiency, which is ensured by boiler exhaust gases recirculation into the blown air, have been investigated. Practical value. The obtained research results will be used in the design of systems of recirculation and heat recovery of heat-generating devices’ exhaust gases to improve their environmental and thermal efficiency.","PeriodicalId":19101,"journal":{"name":"Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu","volume":"20 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Problems of operating heating boilers of increased environmental efficiency\",\"authors\":\"N. Fialko, R. Navrodska, S. Shevchuk, R. V. Serhiienko\",\"doi\":\"10.33271/nvngu/2023-6/054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. Ensuring reliable operation of heating heat-generating devices with recirculation and exhaust gas heat recovery. Methodology. The normative methods of thermal calculation for surface heat exchange devices and the software according to the requirements of regulatory methods for this type of equipment for processing the results of our own experimental studies on heat exchange during deep cooling of combustion products of gas-consuming boilers were used. Findings. Calculation studies on the thermal operation modes during the heating period under the conditions of recirculation and heat recovery of flue gases of gas-fired water-heating boiler plants not equipped with air heaters were carried out. The main characteristics were determined of the thermal and humidity operation state for the air-supply ducts of these installations under the conditions of recirculation of flue gases’ part into the blown air. Regularities of temperature and dew point changes in the mixture of admixed gases and air under the conditions of using traditional heat recovery technologies and without them in different boiler modes and with different parts of recirculated gases were established. Problems of ensuring the operability and reliability of such boiler plants are highlighted. It is shown that these problems are related to condensate formation on the internal surfaces of air ducts and their freezing in some operating modes during in the cold period of the heating season. It is also shown that an effective solution to existing problems can be the use of air heaters in heat recovery systems to preheat the blown air before its mixing with recirculation gases. Originality. For the first time, the thermal and humidity operation modes of the air-supply ducts of heating boiler plants with increased environmental efficiency, which is ensured by boiler exhaust gases recirculation into the blown air, have been investigated. Practical value. The obtained research results will be used in the design of systems of recirculation and heat recovery of heat-generating devices’ exhaust gases to improve their environmental and thermal efficiency.\",\"PeriodicalId\":19101,\"journal\":{\"name\":\"Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu\",\"volume\":\"20 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33271/nvngu/2023-6/054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33271/nvngu/2023-6/054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

目的。确保带有再循环和废气热回收装置的供热制热设备可靠运行。方法。使用表面热交换设备热计算规范方法和符合此类设备规范方法要求的软件,处理我们自己对燃气锅炉燃烧产物深度冷却过程中热交换的实验研究结果。研究结果对未配备空气加热器的燃气水暖锅炉设备在烟气再循环和热回收条件下的采暖期热运行模式进行了计算研究。在烟气部分再循环进入吹风的条件下,确定了这些设备送风管道的热湿运行状态的主要特征。确定了在使用传统热回收技术和不使用传统热回收技术的情况下,在不同锅炉模式和不同再循环气体部分的条件下,混合气体和空气混合物的温度和露点变化的规律性。突出强调了确保此类锅炉设备可操作性和可靠性的问题。研究表明,这些问题与空气管道内表面冷凝水的形成以及在供暖季节寒冷时期的某些运行模式下冷凝水的冻结有关。研究还表明,解决现有问题的有效方法是在热回收系统中使用空气加热器,在吹出的空气与再循环气体混合之前对其进行预热。独创性。首次研究了供热锅炉厂送风管道的热湿运行模式,通过锅炉废气再循环到吹出的空气中,提高了环境效益。实用价值。获得的研究成果将用于设计热能设备废气再循环和热回收系统,以提高其环境和热效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Problems of operating heating boilers of increased environmental efficiency
Purpose. Ensuring reliable operation of heating heat-generating devices with recirculation and exhaust gas heat recovery. Methodology. The normative methods of thermal calculation for surface heat exchange devices and the software according to the requirements of regulatory methods for this type of equipment for processing the results of our own experimental studies on heat exchange during deep cooling of combustion products of gas-consuming boilers were used. Findings. Calculation studies on the thermal operation modes during the heating period under the conditions of recirculation and heat recovery of flue gases of gas-fired water-heating boiler plants not equipped with air heaters were carried out. The main characteristics were determined of the thermal and humidity operation state for the air-supply ducts of these installations under the conditions of recirculation of flue gases’ part into the blown air. Regularities of temperature and dew point changes in the mixture of admixed gases and air under the conditions of using traditional heat recovery technologies and without them in different boiler modes and with different parts of recirculated gases were established. Problems of ensuring the operability and reliability of such boiler plants are highlighted. It is shown that these problems are related to condensate formation on the internal surfaces of air ducts and their freezing in some operating modes during in the cold period of the heating season. It is also shown that an effective solution to existing problems can be the use of air heaters in heat recovery systems to preheat the blown air before its mixing with recirculation gases. Originality. For the first time, the thermal and humidity operation modes of the air-supply ducts of heating boiler plants with increased environmental efficiency, which is ensured by boiler exhaust gases recirculation into the blown air, have been investigated. Practical value. The obtained research results will be used in the design of systems of recirculation and heat recovery of heat-generating devices’ exhaust gases to improve their environmental and thermal efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
148
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信