Sayed Abdo, Ibrahim Ziedan, Asmaa Elyamany
{"title":"利用 Spot4 和 Spot5 的交叉校准估算 Egyptsat -1 辐射测量系数","authors":"Sayed Abdo, Ibrahim Ziedan, Asmaa Elyamany","doi":"10.32985/ijeces.14.10.6","DOIUrl":null,"url":null,"abstract":"The pre-processing of satellite data is a vital step in harnessing the full potential of remote sensing pictures. EgyptSat-1, Egypt's first satellite for observing the Earth from a distance, encountered a major obstacle as a considerable amount of the images it captured could not be used since the necessary radiometric coefficients were missing. This study utilises a cross-calibration methodology, taking advantage of the spectral similarity between Spot 4 and Spot 5 as reference satellites, in order to retrieve these difficult-to-obtain coefficients. The analysis demonstrates that the selection of window size in the cross-calibration process is crucial in determining the outcomes. In general, smaller window sizes tend to produce better results. However, there are certain cases when larger windows are more successful, such as in the scenario of EgyptSat-1's band 3 and its cross-calibration with Spot 5. In contrast to a previous study, the new methodology produces much diminished uncertainty factors, indicating a remarkable enhancement in accuracy. The cross-calibration results highlight the significance of selecting the appropriate window size and satellite for accurate calibration, especially for the Near-Infrared (NIR) band, which is highly responsive to these parameters. Moreover, there are differences in the computations of offset and gain between Spot 4 and Spot 5, which further highlight the intricacies involved in radiometric calibration. The results of this study lead to the determination of improved calibration coefficients for EgyptSat -1, with the specific aim of maximising the accuracy of the results and minimising any errors.","PeriodicalId":41912,"journal":{"name":"International Journal of Electrical and Computer Engineering Systems","volume":"3 8","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimating Egyptsat -1 Radiometric Coefficient using Cross Calibration with Spot4 and Spot5\",\"authors\":\"Sayed Abdo, Ibrahim Ziedan, Asmaa Elyamany\",\"doi\":\"10.32985/ijeces.14.10.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The pre-processing of satellite data is a vital step in harnessing the full potential of remote sensing pictures. EgyptSat-1, Egypt's first satellite for observing the Earth from a distance, encountered a major obstacle as a considerable amount of the images it captured could not be used since the necessary radiometric coefficients were missing. This study utilises a cross-calibration methodology, taking advantage of the spectral similarity between Spot 4 and Spot 5 as reference satellites, in order to retrieve these difficult-to-obtain coefficients. The analysis demonstrates that the selection of window size in the cross-calibration process is crucial in determining the outcomes. In general, smaller window sizes tend to produce better results. However, there are certain cases when larger windows are more successful, such as in the scenario of EgyptSat-1's band 3 and its cross-calibration with Spot 5. In contrast to a previous study, the new methodology produces much diminished uncertainty factors, indicating a remarkable enhancement in accuracy. The cross-calibration results highlight the significance of selecting the appropriate window size and satellite for accurate calibration, especially for the Near-Infrared (NIR) band, which is highly responsive to these parameters. Moreover, there are differences in the computations of offset and gain between Spot 4 and Spot 5, which further highlight the intricacies involved in radiometric calibration. The results of this study lead to the determination of improved calibration coefficients for EgyptSat -1, with the specific aim of maximising the accuracy of the results and minimising any errors.\",\"PeriodicalId\":41912,\"journal\":{\"name\":\"International Journal of Electrical and Computer Engineering Systems\",\"volume\":\"3 8\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical and Computer Engineering Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32985/ijeces.14.10.6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical and Computer Engineering Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32985/ijeces.14.10.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

卫星数据的预处理是充分发挥遥感图片潜力的关键一步。埃及第一颗用于远距离观测地球的卫星 EgyptSat-1 遇到了一个重大障碍,由于缺少必要的辐射系数,它拍摄的大量图像无法使用。本研究采用交叉校准方法,利用作为参考卫星的 Spot 4 和 Spot 5 之间的光谱相似性来检索这些难以获得的系数。分析表明,交叉校准过程中窗口大小的选择对结果的决定至关重要。一般来说,窗口尺寸越小,结果越好。不过,在某些情况下,较大的窗口会更成功,例如埃及卫星 1 号的波段 3 及其与 Spot 5 的交叉校准。与之前的研究相比,新方法产生的不确定系数大大降低,表明精度显著提高。交叉校准结果凸显了选择适当的窗口大小和卫星对精确校准的重要性,尤其是对近红外波段,因为该波段对这些参数的反应非常灵敏。此外,4 号观测点和 5 号观测点在偏移和增益的计算上存在差异,这进一步凸显了辐射校准所涉及的复杂性。这项研究的结果有助于确定埃及卫星-1 的改进校准系数,其具体目标是最大限度地提高结果的准确性并将误差降至最低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimating Egyptsat -1 Radiometric Coefficient using Cross Calibration with Spot4 and Spot5
The pre-processing of satellite data is a vital step in harnessing the full potential of remote sensing pictures. EgyptSat-1, Egypt's first satellite for observing the Earth from a distance, encountered a major obstacle as a considerable amount of the images it captured could not be used since the necessary radiometric coefficients were missing. This study utilises a cross-calibration methodology, taking advantage of the spectral similarity between Spot 4 and Spot 5 as reference satellites, in order to retrieve these difficult-to-obtain coefficients. The analysis demonstrates that the selection of window size in the cross-calibration process is crucial in determining the outcomes. In general, smaller window sizes tend to produce better results. However, there are certain cases when larger windows are more successful, such as in the scenario of EgyptSat-1's band 3 and its cross-calibration with Spot 5. In contrast to a previous study, the new methodology produces much diminished uncertainty factors, indicating a remarkable enhancement in accuracy. The cross-calibration results highlight the significance of selecting the appropriate window size and satellite for accurate calibration, especially for the Near-Infrared (NIR) band, which is highly responsive to these parameters. Moreover, there are differences in the computations of offset and gain between Spot 4 and Spot 5, which further highlight the intricacies involved in radiometric calibration. The results of this study lead to the determination of improved calibration coefficients for EgyptSat -1, with the specific aim of maximising the accuracy of the results and minimising any errors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
11.80%
发文量
69
期刊介绍: The International Journal of Electrical and Computer Engineering Systems publishes original research in the form of full papers, case studies, reviews and surveys. It covers theory and application of electrical and computer engineering, synergy of computer systems and computational methods with electrical and electronic systems, as well as interdisciplinary research. Power systems Renewable electricity production Power electronics Electrical drives Industrial electronics Communication systems Advanced modulation techniques RFID devices and systems Signal and data processing Image processing Multimedia systems Microelectronics Instrumentation and measurement Control systems Robotics Modeling and simulation Modern computer architectures Computer networks Embedded systems High-performance computing Engineering education Parallel and distributed computer systems Human-computer systems Intelligent systems Multi-agent and holonic systems Real-time systems Software engineering Internet and web applications and systems Applications of computer systems in engineering and related disciplines Mathematical models of engineering systems Engineering management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信